2b first flange single connection facility thread class, copper alloy all flange material, gold all tubing segment inside surfaces and silver all tubing segment inside surfaces surface treatment, unc first flange single connection facility thread series designator.
Right-hand first flange single connection facility bend type.
Includes quality control certificate of conformance.
-
Cross Sectional Shape:
Internal, rectangular external, rectangular
-
Thread Direction:
Right-hand first flange single connection facility
-
Bend Angle In Deg:
31.0 first bend e-plane
-
Bend Angle In Deg:
45.0 third bend h-plane
-
Bend Angle In Deg:
45.0 second bend h-plane
-
Tubing Wall Construction Style:
Seamless single tubing segment
-
Flange Quantity:
2
-
Flange Inside Width:
1.119 inches first flange and 1.125 inches first flange
-
Flange Inside Width:
1.310 inches second flange and 1.314 inches second flange
-
Flange Inside Height:
0.494 inches first flange and 0.500 inches first flange
-
Flange Inside Height:
0.628 inches second flange and 0.631 inches second flange
-
Flange Outside Width:
3.250 inches first flange
-
Flange Outside Width:
3.250 inches second flange
-
Flange Outside Height:
1.867 inches first flange and 1.883 inches first flange
-
Flange Outside Height:
1.867 inches second flange and 1.883 inches second flange
-
Flange Depth:
0.433 inches second flange and 0.442 inches second flange
-
Flange Depth:
0.620 inches first flange and 0.630 inches first flange
-
Flange Connecting Hole Diameter:
0.167 inches second flange single connection facility and 0.175 inches second flange single connection facility
-
Maximum Operating Pressure:
12.0 pounds per square inch gage
-
Waveguide Outside Width:
1.375 inches
-
Thread Size:
0.164 inches first flange single connection facility
-
Waveguide Inside Width:
Between 1.001 inches and 1.007 inches
-
Waveguide Inside Height:
Between 0.494 inches and 0.500 inches
-
Waveguide Outside Height:
0.750 inches
-
Waveguide Longer Offset Distance:
Between 5.422 inches and 5.452 inches
-
Flange Connecting Facility And Quantity:
8 threaded hole first flange single connection facility
-
Flange Connecting Facility And Quantity:
8 unthreaded hole second flange single connection facility
-
Flange Style:
Contact type first flange
-
Flange Style:
Cover type second flange
-
Waveguide Offset Distance:
Between 2.860 inches and 2.890 inches
-
Flexibility:
Rigid single tubing segment
-
Style Designator:
Bend type
-
Federal Supply Class (fsc):
Antennas, waveguides, and related equipment
-
National Stock Number (nsn):
5985-00-072-9644
-
Special Features:
One 0.375 in. Diameter copper tube on each side of waveguide through each flange