Features
2b first flange single connection facility thread class, copper alloy single tubing segment material, any acceptable all tubing segment and flange all surfaces surface treatment, unc first flange single connection facility thread series designator.
Right-hand first flange single connection facility corner type.
Includes quality control certificate of conformance.
Specifications
-
Cross Sectional Shape:
Internal, rectangular external, rectangular
-
Thread Direction:
Right-hand first flange single connection facility
-
Bend Angle In Deg:
90.0 single bend h-plane
-
Tubing Wall Construction Style:
Seamless single tubing segment
-
Flange Quantity:
2
-
Flange Inside Height:
0.311 inches first flange
-
Flange Inside Height:
0.394 inches second flange
-
Flange Outside Width:
1.312 inches first flange
-
Flange Outside Width:
1.313 inches second flange
-
Flange Outside Height:
1.313 inches second flange
-
Flange Outside Height:
1.312 inches first flange
-
Flange Inside Diameter:
0.710 inches first flange
-
Flange Depth:
0.313 inches second flange
-
Flange Depth:
0.375 inches first flange
-
Flange Connecting Hole Diameter:
0.144 inches second flange single connection facility
-
Voltage Standing Wave Ratio:
1.05
-
Waveguide Outside Width:
0.702 inches
-
Thread Size:
0.138 inches first flange single connection facility
-
Waveguide Inside Width:
0.622 inches
-
Waveguide Inside Height:
0.391 inches
-
Waveguide Outside Height:
0.311 inches
-
Waveguide Longer Offset Distance:
3.000 inches
-
Flange Connecting Facility And Quantity:
2 threaded hole first flange single connection facility
-
Flange Connecting Facility And Quantity:
2 unthreaded hole second flange single connection facility
-
Flange Style:
Choke type first flange
-
Flange Style:
Cover type second flange
-
Waveguide Offset Distance:
0.969 inches
-
Flexibility:
Rigid single tubing segment
-
Style Designator:
Corner type
-
Federal Supply Class (fsc):
Antennas, waveguides, and related equipment
-
National Stock Number (nsn):
5985-01-035-5243