2b second flange single connection facility thread class, aluminum alloy single tubing segment material, oxide film all tubing segment and flange outside surfaces surface treatment, unc second flange single connection facility thread series designator.
Right-hand second flange single connection facility bend type.
Includes quality control certificate of conformance.
-
Cross Sectional Shape:
Internal, rectangular external, rectangular
-
Thread Direction:
Right-hand second flange single connection facility
-
Bend Angle In Deg:
90.0 single bend e-plane
-
Tubing Wall Construction Style:
Seamless single tubing segment
-
Flange Quantity:
2
-
Flange Inside Width:
0.897 inches second flange and 0.903 inches second flange
-
Flange Inside Width:
1.003 inches first flange and 1.006 inches first flange
-
Flange Inside Height:
0.397 inches second flange and 0.403 inches second flange
-
Flange Inside Height:
0.503 inches first flange and 0.506 inches first flange
-
Flange Outside Width:
1.610 inches first flange and 1.640 inches first flange
-
Flange Outside Width:
1.610 inches second flange and 1.640 inches second flange
-
Flange Outside Height:
1.610 inches second flange and 1.640 inches second flange
-
Flange Outside Height:
1.610 inches first flange and 1.640 inches first flange
-
Flange Depth:
0.422 inches first flange and 0.453 inches first flange
-
Flange Depth:
0.423 inches second flange and 0.453 inches second flange
-
Flange Connecting Hole Diameter:
0.169 inches first flange single connection facility
-
Voltage Standing Wave Ratio:
1.05
-
Insertion Loss In Decibels:
0.10
-
Maximum Operating Pressure:
20.0 pounds per square inch gage
-
Waveguide Outside Width:
Between 0.996 inches and 1.004 inches
-
Thread Size:
0.164 inches second flange single connection facility
-
Waveguide Inside Width:
Between 0.896 inches and 0.904 inches
-
Waveguide Inside Height:
Between 0.396 inches and 0.404 inches
-
Waveguide Outside Height:
Between 0.496 inches and 0.504 inches
-
Waveguide Longer Offset Distance:
2.412 inches
-
Flange Connecting Facility And Quantity:
4 threaded hole second flange single connection facility
-
Flange Connecting Facility And Quantity:
4 unthreaded hole first flange single connection facility
-
Flange Style:
Choke type second flange
-
Flange Style:
Cover type first flange
-
Waveguide Offset Distance:
1.250 inches
-
Flexibility:
Rigid single tubing segment
-
Style Designator:
Bend type
-
Federal Supply Class (fsc):
Antennas, waveguides, and related equipment
-
National Stock Number (nsn):
5985-00-556-6010
-
Special Features:
Tubing wall construction can also be laminated