2b first flange single connection facility thread class, aluminum alloy single tubing segment material, oxide film all tubing segment and flange outside surfaces surface treatment, unc first flange single connection facility thread series designator.
Right-hand first flange single connection facility bend type.
Includes quality control certificate of conformance.
-
Cross Sectional Shape:
Internal, rectangular external, rectangular
-
Thread Direction:
Right-hand first flange single connection facility
-
Bend Angle In Deg:
45.0 third bend e-plane
-
Bend Angle In Deg:
45.0 second bend e-plane
-
Bend Angle In Deg:
90.0 first bend e-plane
-
Tubing Wall Construction Style:
Seamless single tubing segment
-
Flange Quantity:
2
-
Flange Inside Width:
1.118 inches all flanges and 1.126 inches all flanges
-
Flange Inside Height:
0.493 inches all flanges and 0.501 inches all flanges
-
Flange Outside Width:
2.480 inches all flanges and 2.520 inches all flanges
-
Flange Outside Height:
1.730 inches all flanges and 1.770 inches all flanges
-
Flange Depth:
0.480 inches all flanges and 0.520 inches all flanges
-
Flange Connecting Hole Diameter:
0.167 inches second flange single connection facility and 0.171 inches second flange single connection facility
-
Voltage Standing Wave Ratio:
1.10
-
Insertion Loss In Decibels:
0.09
-
Maximum Operating Pressure:
10.0 pounds per square inch gage
-
Waveguide Outside Width:
Between 1.246 inches and 1.254 inches
-
Thread Size:
0.164 inches first flange single connection facility
-
Waveguide Inside Width:
Between 1.118 inches and 1.126 inches
-
Waveguide Inside Height:
Between 0.493 inches and 0.501 inches
-
Waveguide Outside Height:
Between 0.621 inches and 0.629 inches
-
Waveguide Longer Offset Distance:
2.031 feet
-
Flange Connecting Facility And Quantity:
8 threaded hole first flange single connection facility
-
Flange Connecting Facility And Quantity:
8 unthreaded hole second flange single connection facility
-
Flange Style:
Contact type all flanges
-
Waveguide Offset Distance:
1.000 inches
-
Flexibility:
Rigid single tubing segment
-
Style Designator:
Bend type
-
Federal Supply Class (fsc):
Antennas, waveguides, and related equipment
-
National Stock Number (nsn):
5985-00-548-4276
-
Special Features:
Tubing wall construction can also be laminated