Features
Copper alloy all tubing segment and flange material, paint all tubing segment and flange outside surfaces surface treatment.
Bend type.
Includes quality control certificate of conformance.
Specifications
-
Cross Sectional Shape:
Internal, rectangular external, rectangular
-
Tubing Wall Construction Style:
Seamless single tubing segment
-
Flange Quantity:
2
-
Waveguide Outside Width:
Between 0.302 inches and 0.306 inches
-
Waveguide Inside Width:
Between 0.222 inches and 0.226 inches
-
Waveguide Inside Height:
Between 0.110 inches and 0.114 inches
-
Waveguide Outside Height:
Between 0.190 inches and 0.194 inches
-
Waveguide Longer Offset Distance:
0.880 inches
-
Waveguide Offset Distance:
0.880 inches
-
Flexibility:
Rigid single tubing segment
-
Style Designator:
Bend type
-
Federal Supply Class (fsc):
Antennas, waveguides, and related equipment
-
National Stock Number (nsn):
5985-01-351-1931