Waveguide Assemblies - Page 208 of 698

17428 part numbers
2665374-1
View Part NSN 5985-01-039-1434
266544
View Part NSN 5985-01-446-2416 Cross Reference: 106352, 229301, 2901749-1
  • End Application: F-15i lantirn
  • Special Features: Input waveguide
2665696-1
View Part NSN 5985-00-175-7018 Cross Reference: H-117-FS-9.8, TS-68627
  • Cross Sectional Shape: Internal, rectangular external, rectangular
  • End Application: Radar set an/spg-51d
  • Tubing Wall Construction Style: Corrugated single tubing segment
  • Flange Quantity: 2
  • Voltage Standing Wave Ratio: 1.08
2665732
View Part NSN 5985-01-029-5007
  • Waveguide Length: 70.730 inches
  • Flexibility: Rigid single tubing segment
  • Style Designator: Offset bend type
2665732-2
View Part NSN 5985-01-187-4963 Cross Reference: TR785199
  • Bend Angle In Deg: 45.0 first bend e-plane
  • Flange Quantity: 2
  • Voltage Standing Wave Ratio: 1.07
  • Maximum Operating Pressure: 10.0 pounds per square inch gage
  • Waveguide Center To Center Distance: 1.440 inches
2665737
View Part NSN 5985-01-147-7472
  • Cross Sectional Shape: Internal, rectangular external, rectangular
  • Tubing Wall Construction Style: Seamless all tubing segment
  • Flange Quantity: 2
  • Voltage Standing Wave Ratio: 1.10
  • Maximum Operating Pressure: 10.0 pounds per square inch gage
2665739
View Part NSN 5985-01-200-2790
  • Cross Sectional Shape: Internal, rectangular external, rectangular
  • Bend Angle In Deg: 75.0 single bend e-plane
  • End Application: Radar set an/spg-51d
  • Tubing Wall Construction Style: Seamless single tubing segment
  • Flange Quantity: 2
2665740
View Part NSN 5985-01-197-9918
  • Cross Sectional Shape: Internal, rectangular external, rectangular
  • Tubing Wall Construction Style: Seamless all tubing segment
  • Flange Quantity: 3
  • Voltage Standing Wave Ratio: 1.10
  • Maximum Operating Pressure: 10.0 pounds per square inch gage
2665741
View Part NSN 5985-01-155-2035 Cross Reference: TR685098
  • Cross Sectional Shape: Internal, rectangular external, rectangular
  • Bend Angle In Deg: 38.0 single bend e-plane
  • End Application: Radar set an/spg-51d
  • Tubing Wall Construction Style: Seamless single tubing segment
  • Flange Quantity: 2
2665742-1
View Part NSN 5985-01-212-8686 Cross Reference: TS78183
  • Cross Sectional Shape: Internal, rectangular external, rectangular
  • Bend Angle In Deg: 45.0 second bend e-plane
  • End Application: Radar set an/spg-51d
  • Tubing Wall Construction Style: Corrugated single tubing segment
  • Flange Quantity: 2
2665743-1
View Part NSN 5985-01-183-7993 Cross Reference: TS68628
  • Cross Sectional Shape: Internal, rectangular external, rectangular
  • Thread Class: 2b all flanges single connection facility
  • Tubing Wall Construction Style: Corrugated single tubing segment
  • Flange Quantity: 2
  • Voltage Standing Wave Ratio: 1.02
2665743-2
View Part NSN 5985-01-208-5447
  • Cross Sectional Shape: Internal, rectangular external, rectangular
  • Thread Class: 2b all flanges all connection facilities
  • Tubing Wall Construction Style: Corrugated single tubing segment
  • Flange Quantity: 2
  • Thready Qty Per Inch (tpi): 32 all flanges all connection facilities
2665746-2
View Part NSN 5985-01-155-2036
  • Cross Sectional Shape: Internal, rectangular external, rectangular
  • End Application: Radar set an/spg-51d
  • Tubing Wall Construction Style: Seamless single tubing segment
  • Flange Quantity: 2
  • Maximum Operating Pressure: 10.0 pounds per square inch gage
2665747
View Part NSN 5985-01-168-8312
  • Cross Sectional Shape: Internal, rectangular external, rectangular
  • End Application: Radar set an/spg-51d
  • Tubing Wall Construction Style: Seamless single tubing segment
  • Flange Quantity: 2
  • Maximum Operating Pressure: 10.0 pounds per square inch gage
2665748-1
View Part NSN 5985-01-212-8687
  • Cross Sectional Shape: Internal, rectangular external, rectangular
  • Bend Angle In Deg: 45.0 second bend h-plane
  • Tubing Wall Construction Style: Seamless single tubing segment
  • Flange Quantity: 2
  • Voltage Standing Wave Ratio: 1.07
2665868
View Part NSN 5985-01-062-7915
  • Flange Quantity: 2
  • Voltage Standing Wave Ratio: 1.03
  • Waveguide Length: 32.500 inches
  • Style Designator: Straight type
2665950
View Part NSN 5985-01-147-7473
  • Cross Sectional Shape: Internal, rectangular external, rectangular
  • Tubing Wall Construction Style: Seamless single tubing segment
  • Flange Quantity: 2
  • Maximum Operating Pressure: 10.0 pounds per square inch gage
  • Waveguide Length: Between 1.961 inches and 1.965 inches
2665951
View Part NSN 5985-01-183-7994
  • Cross Sectional Shape: Internal, rectangular external, rectangular
  • Bend Angle In Deg: 90.0 single bend e-plane
  • End Application: Radar set an/spg-51d
  • Tubing Wall Construction Style: Seamless all tubing segment
  • Flange Quantity: 2
2665952
View Part NSN 5985-01-033-6972
  • Cross Sectional Shape: Internal, rectangular external, rectangular
  • End Application: Radar set an/spg-51d
  • Tubing Wall Construction Style: Seamless all tubing segment
  • Flange Quantity: 1
  • Voltage Standing Wave Ratio: 1.10
2665953
View Part NSN 5985-01-168-8313
  • Cross Sectional Shape: Internal, rectangular external, rectangular
  • Bend Angle In Deg: 90.0 single bend e-plane
  • Tubing Wall Construction Style: Seamless all tubing segment
  • Flange Quantity: 2
  • Voltage Standing Wave Ratio: 1.06
2665954
View Part NSN 5985-01-200-2791
  • Cross Sectional Shape: Internal, rectangular external, rectangular
  • Bend Angle In Deg: 90.0 single bend h-plane
  • End Application: Radar set an/spg-51d
  • Tubing Wall Construction Style: Seamless all tubing segment
  • Flange Quantity: 2
2665971
View Part NSN 5985-01-148-4904
  • Cross Sectional Shape: Internal, rectangular external, rectangular
  • End Application: Radar set an/spg-51d
  • Tubing Wall Construction Style: Seamless single tubing segment
  • Flange Quantity: 2
  • Flange Depth: 0.360 inches all flanges
2665972
View Part NSN 5985-01-005-1723
  • Cross Sectional Shape: Internal, rectangular external, rectangular
  • End Application: Radar set an/spg-51d
  • Tubing Wall Construction Style: Seamless all tubing segment
  • Flange Quantity: 2
  • Voltage Standing Wave Ratio: 1.10
2665973
View Part NSN 5985-01-004-6017
  • Cross Sectional Shape: Internal, rectangular external, rectangular
  • Bend Angle In Deg: 67.0 first bend h-plane
  • End Application: Radar set an/spg-51d
  • Tubing Wall Construction Style: Seamless single tubing segment
  • Flange Quantity: 2
2665979-1
View Part NSN 5985-00-177-6258 Cross Reference: 47484
  • Cross Sectional Shape: Internal, rectangular external, rectangular
  • Thread Class: 2b all flanges all connection facilities
  • End Application: Radar set an/spg-51d
  • Tubing Wall Construction Style: Corrugated single tubing segment
  • Flange Quantity: 2