Waveguide Assemblies - Page 208 of 698
17428 part numbers
266544
View Part
NSN 5985-01-446-2416
Cross Reference:
106352, 229301, 2901749-1
-
End Application: F-15i lantirn
-
Special Features: Input waveguide
2665696-1
View Part
NSN 5985-00-175-7018
Cross Reference:
H-117-FS-9.8, TS-68627
-
Cross Sectional Shape: Internal, rectangular external, rectangular
-
End Application: Radar set an/spg-51d
-
Tubing Wall Construction Style: Corrugated single tubing segment
-
Flange Quantity: 2
-
Voltage Standing Wave Ratio: 1.08
-
Waveguide Length: 70.730 inches
-
Flexibility: Rigid single tubing segment
-
Style Designator: Offset bend type
2665732-2
View Part
NSN 5985-01-187-4963
Cross Reference:
TR785199
-
Bend Angle In Deg: 45.0 first bend e-plane
-
Flange Quantity: 2
-
Voltage Standing Wave Ratio: 1.07
-
Maximum Operating Pressure: 10.0 pounds per square inch gage
-
Waveguide Center To Center Distance: 1.440 inches
-
Cross Sectional Shape: Internal, rectangular external, rectangular
-
Tubing Wall Construction Style: Seamless all tubing segment
-
Flange Quantity: 2
-
Voltage Standing Wave Ratio: 1.10
-
Maximum Operating Pressure: 10.0 pounds per square inch gage
-
Cross Sectional Shape: Internal, rectangular external, rectangular
-
Bend Angle In Deg: 75.0 single bend e-plane
-
End Application: Radar set an/spg-51d
-
Tubing Wall Construction Style: Seamless single tubing segment
-
Flange Quantity: 2
-
Cross Sectional Shape: Internal, rectangular external, rectangular
-
Tubing Wall Construction Style: Seamless all tubing segment
-
Flange Quantity: 3
-
Voltage Standing Wave Ratio: 1.10
-
Maximum Operating Pressure: 10.0 pounds per square inch gage
2665741
View Part
NSN 5985-01-155-2035
Cross Reference:
TR685098
-
Cross Sectional Shape: Internal, rectangular external, rectangular
-
Bend Angle In Deg: 38.0 single bend e-plane
-
End Application: Radar set an/spg-51d
-
Tubing Wall Construction Style: Seamless single tubing segment
-
Flange Quantity: 2
2665742-1
View Part
NSN 5985-01-212-8686
Cross Reference:
TS78183
-
Cross Sectional Shape: Internal, rectangular external, rectangular
-
Bend Angle In Deg: 45.0 second bend e-plane
-
End Application: Radar set an/spg-51d
-
Tubing Wall Construction Style: Corrugated single tubing segment
-
Flange Quantity: 2
2665743-1
View Part
NSN 5985-01-183-7993
Cross Reference:
TS68628
-
Cross Sectional Shape: Internal, rectangular external, rectangular
-
Thread Class: 2b all flanges single connection facility
-
Tubing Wall Construction Style: Corrugated single tubing segment
-
Flange Quantity: 2
-
Voltage Standing Wave Ratio: 1.02
-
Cross Sectional Shape: Internal, rectangular external, rectangular
-
Thread Class: 2b all flanges all connection facilities
-
Tubing Wall Construction Style: Corrugated single tubing segment
-
Flange Quantity: 2
-
Thready Qty Per Inch (tpi): 32 all flanges all connection facilities
-
Cross Sectional Shape: Internal, rectangular external, rectangular
-
End Application: Radar set an/spg-51d
-
Tubing Wall Construction Style: Seamless single tubing segment
-
Flange Quantity: 2
-
Maximum Operating Pressure: 10.0 pounds per square inch gage
-
Cross Sectional Shape: Internal, rectangular external, rectangular
-
End Application: Radar set an/spg-51d
-
Tubing Wall Construction Style: Seamless single tubing segment
-
Flange Quantity: 2
-
Maximum Operating Pressure: 10.0 pounds per square inch gage
-
Cross Sectional Shape: Internal, rectangular external, rectangular
-
Bend Angle In Deg: 45.0 second bend h-plane
-
Tubing Wall Construction Style: Seamless single tubing segment
-
Flange Quantity: 2
-
Voltage Standing Wave Ratio: 1.07
-
Flange Quantity: 2
-
Voltage Standing Wave Ratio: 1.03
-
Waveguide Length: 32.500 inches
-
Style Designator: Straight type
-
Cross Sectional Shape: Internal, rectangular external, rectangular
-
Tubing Wall Construction Style: Seamless single tubing segment
-
Flange Quantity: 2
-
Maximum Operating Pressure: 10.0 pounds per square inch gage
-
Waveguide Length: Between 1.961 inches and 1.965 inches
-
Cross Sectional Shape: Internal, rectangular external, rectangular
-
Bend Angle In Deg: 90.0 single bend e-plane
-
End Application: Radar set an/spg-51d
-
Tubing Wall Construction Style: Seamless all tubing segment
-
Flange Quantity: 2
-
Cross Sectional Shape: Internal, rectangular external, rectangular
-
End Application: Radar set an/spg-51d
-
Tubing Wall Construction Style: Seamless all tubing segment
-
Flange Quantity: 1
-
Voltage Standing Wave Ratio: 1.10
-
Cross Sectional Shape: Internal, rectangular external, rectangular
-
Bend Angle In Deg: 90.0 single bend e-plane
-
Tubing Wall Construction Style: Seamless all tubing segment
-
Flange Quantity: 2
-
Voltage Standing Wave Ratio: 1.06
-
Cross Sectional Shape: Internal, rectangular external, rectangular
-
Bend Angle In Deg: 90.0 single bend h-plane
-
End Application: Radar set an/spg-51d
-
Tubing Wall Construction Style: Seamless all tubing segment
-
Flange Quantity: 2
-
Cross Sectional Shape: Internal, rectangular external, rectangular
-
End Application: Radar set an/spg-51d
-
Tubing Wall Construction Style: Seamless single tubing segment
-
Flange Quantity: 2
-
Flange Depth: 0.360 inches all flanges
-
Cross Sectional Shape: Internal, rectangular external, rectangular
-
End Application: Radar set an/spg-51d
-
Tubing Wall Construction Style: Seamless all tubing segment
-
Flange Quantity: 2
-
Voltage Standing Wave Ratio: 1.10
-
Cross Sectional Shape: Internal, rectangular external, rectangular
-
Bend Angle In Deg: 67.0 first bend h-plane
-
End Application: Radar set an/spg-51d
-
Tubing Wall Construction Style: Seamless single tubing segment
-
Flange Quantity: 2
2665979-1
View Part
NSN 5985-00-177-6258
Cross Reference:
47484
-
Cross Sectional Shape: Internal, rectangular external, rectangular
-
Thread Class: 2b all flanges all connection facilities
-
End Application: Radar set an/spg-51d
-
Tubing Wall Construction Style: Corrugated single tubing segment
-
Flange Quantity: 2