Waveguide Assemblies - Page 442 of 698

17428 part numbers
898706-1
View Part NSN 5985-01-069-8984
  • Maximum Operating Pressure: 26.0 pounds per square inch gage
  • Waveguide Length: 3.750 inches
  • Special Features: Rigid construction
  • Style Designator: Straight type
89946-506-1
View Part NSN 5985-00-983-8298 Cross Reference: P2172
  • Flange Quantity: 2
  • Maximum Operating Pressure: 35.0 pounds per square inch gage
  • Material: Aluminum alloy all flange
  • Surface Treatment: Enamel all flange outside surfaces
89W653P002
View Part NSN 5985-01-494-3139 Cross Reference: AMC1481, AMC1481-WAVEGUIDE 19.75 IN LONG, FS-100P-N-3AC3AC-I19, FS-100P-N-3AC-3AC-L19.745
  • Cross Sectional Shape: Internal, rectangular external, rectangular
  • Tubing Wall Construction Style: Corrugated all tubing segment
  • Flange Quantity: 2
  • Voltage Standing Wave Ratio: 1.728
  • Insertion Loss In Decibels: 0.049
COBHAM ADVANCED ELECTRONIC SOLUTIONS P/N 8H62
View Part NSN 5985-01-268-4077 Cross Reference: 1310AS2198
9000109
View Part NSN 5985-00-534-1409
  • Cross Sectional Shape: Internal, rectangular external, rectangular
  • Flange Quantity: 2
  • Voltage Standing Wave Ratio: 1.04
  • Waveguide Outside Width: 1.750 inches
  • Waveguide Inside Width: 1.122 inches
9002284
View Part NSN 5985-00-135-6594
  • Flange Quantity: 2
9002546
View Part NSN 5985-00-622-9266
  • Fsc Application Data: Transponder control group guided missile
9002655
View Part NSN 5985-00-622-1556
  • Flange Quantity: 2
  • Voltage Standing Wave Ratio: 1.30
9002659
View Part NSN 5985-00-621-5298
  • Flange Quantity: 2
  • Flange Style: Cover type second flange
  • Fsc Application Data: Transponder set missile guidance system
9002661
View Part NSN 5985-00-622-9265
  • Fsc Application Data: Transponder control group guided missile
9004535
View Part NSN 5985-00-612-6507
  • Cross Sectional Shape: Internal, rectangular external, rectangular
  • Tubing Wall Construction Style: Seamless single tubing segment
  • Flange Quantity: 2
  • Voltage Standing Wave Ratio: 1.30
  • Waveguide Outside Width: 1.000 inches
9005431
View Part NSN 5985-00-819-5161 Cross Reference: TL68111
  • Cross Sectional Shape: Internal, rectangular external, rectangular
  • Flange Quantity: 2
  • Flange Inside Width: 1.253 inches all flanges
  • Flange Outside Width: 1.875 inches all flanges
  • Flange Outside Height: 1.875 inches all flanges
9006384
View Part NSN 5985-00-133-4038
9006506
View Part NSN 5985-00-021-2331
9007515
View Part NSN 5985-00-578-7739 Cross Reference: BN720-1700, G243692-5, TS68281
  • Cross Sectional Shape: Internal, rectangular external, rectangular
  • Tubing Wall Construction Style: Seamless single tubing segment
  • Flange Quantity: 2
  • Flange Inside Width: 1.253 inches second flange
  • Flange Inside Height: 0.628 inches second flange
9007516
View Part NSN 5985-00-578-7740 Cross Reference: BN720-2400, G243692-6, TL68115
  • Cross Sectional Shape: Internal, rectangular external, rectangular
  • Tubing Wall Construction Style: Seamless single tubing segment
  • Flange Quantity: 2
  • Flange Inside Width: 1.253 inches second flange
  • Flange Inside Height: 0.628 inches second flange
9007629
View Part NSN 5985-00-614-0558
  • Flange Quantity: 2
  • Voltage Standing Wave Ratio: 1.10
  • Fsc Application Data: Transponder control group guided missile
9007631
View Part NSN 5985-00-614-0556
  • Flange Quantity: 2
  • Voltage Standing Wave Ratio: 1.10
  • Fsc Application Data: Guidance section guided missile
9009051
View Part NSN 5985-00-614-9295
  • Cross Sectional Shape: Internal, rectangular external, rectangular
  • Tubing Wall Construction Style: Seamless single tubing segment
  • Tubing Twist Type: Straight twist single tubing segment
  • Tubing Twist Angle In Deg: 45.0 single tubing segment
  • Flange Quantity: 2
9009558
View Part NSN 5985-00-614-0557
  • Flange Quantity: 2
  • Voltage Standing Wave Ratio: 1.10
  • Fsc Application Data: Guidance section guided missile
900C487H01
View Part NSN 5985-00-427-9927 Cross Reference: M11-51174
  • Cross Sectional Shape: Internal, rectangular external, rectangular
  • Thread Class: 2b first flange all connection facilities
  • Tubing Wall Construction Style: Seamless single tubing segment
  • Flange Quantity: 2
  • Voltage Standing Wave Ratio: 1.30
90-120-3-77B
View Part NSN 5985-00-905-8977 Cross Reference: 641-1, 90-220-03-2, MDC95121-90-1-3
  • Cross Sectional Shape: Internal, rectangular external, rectangular
  • Tubing Wall Construction Style: Seamless single tubing segment
  • Flange Quantity: 2
  • Waveguide Outside Width: Between 0.996 inches and 1.004 inches
  • Waveguide Inside Width: Between 0.869 inches and 0.904 inches
9012155
View Part NSN 5985-00-825-1425
  • Cross Sectional Shape: Internal, rectangular external, rectangular
  • Tubing Wall Construction Style: Seamless single tubing segment
  • Flange Quantity: 2
  • Flange Inside Diameter: 1.005 inches second flange
  • Maximum Operating Pressure: 30.0 pounds per square inch gage
9012222
View Part NSN 5985-00-825-1424
  • Cross Sectional Shape: Internal, rectangular external, rectangular
  • Tubing Wall Construction Style: Seamless single tubing segment
  • Flange Quantity: 2
  • Flange Outside Height: 1.298 inches all flanges
  • Flange Inside Diameter: 1.005 inches second flange
9012233
View Part NSN 5985-00-825-1426
  • Cross Sectional Shape: Internal, rectangular external, rectangular
  • Flange Quantity: 2
  • Flange Outside Height: 1.328 inches second flange
  • Maximum Operating Pressure: 30.0 pounds per square inch gage
  • Waveguide Outside Width: 0.702 inches