Waveguide Assemblies - Page 456 of 698
17428 part numbers
-
End Application: Mc130h acft
-
Flange Quantity: 2
-
Voltage Standing Wave Ratio: 1.27
-
Maximum Operating Pressure: 25.0 pounds per square inch gage
-
Waveguide Longer Offset Distance: 16.250 inches
-
End Application: Mc130h acft
-
Flange Quantity: 2
-
Voltage Standing Wave Ratio: 1.30
-
Maximum Operating Pressure: 25.0 pounds per square inch gage
-
Waveguide Length: 23.250 inches
-
End Application: Mc130h acft
-
Flange Quantity: 2
-
Voltage Standing Wave Ratio: 1.30
-
Maximum Operating Pressure: 25.0 pounds per square inch gage
-
Flexibility: Rigid third tubing segment
-
End Application: Mc130h acft
-
Flange Quantity: 2
-
Voltage Standing Wave Ratio: 1.30
-
Maximum Operating Pressure: 25.0 pounds per square inch gage
-
Waveguide Longer Offset Distance: 15.250 inches
-
End Application: Mc130h acft
-
Flange Quantity: 2
-
Voltage Standing Wave Ratio: 1.21
-
Maximum Operating Pressure: 25.0 pounds per square inch gage
-
Waveguide Longer Offset Distance: 64.600 inches
-
End Application: Mc130h acft
-
Flange Quantity: 2
-
Voltage Standing Wave Ratio: 1.21
-
Maximum Operating Pressure: 25.0 pounds per square inch gage
-
Waveguide Longer Offset Distance: 61.750 inches
-
End Application: Mc130h acft
-
Flange Quantity: 2
-
Voltage Standing Wave Ratio: 1.21
-
Maximum Operating Pressure: 25.0 pounds per square inch gage
-
Waveguide Longer Offset Distance: 63.250 inches
-
End Application: Mc130h acft
-
Flange Quantity: 2
-
Voltage Standing Wave Ratio: 1.27
-
Maximum Operating Pressure: 25.0 pounds per square inch gage
-
Waveguide Length: 49.630 inches
-
End Application: Mc130h acft
-
Flange Quantity: 2
-
Voltage Standing Wave Ratio: 1.27
-
Maximum Operating Pressure: 25.0 pounds per square inch gage
-
Waveguide Length: 45.630 inches
-
End Application: Ct 2 mc130h aircraft mods
-
Tubing Wall Construction Style: Seamless single tubing segment
-
Flange Quantity: 2
-
Insertion Loss In Decibels: 0.70
-
Maximum Operating Pressure: 25.0 pounds per square inch gage
-
End Application: Mc130h acft
-
Flange Quantity: 2
-
Voltage Standing Wave Ratio: 1.35
-
Maximum Operating Pressure: 25.0 pounds per square inch gage
-
Waveguide Length: 42.800 inches
-
End Application: Mc130h acft
-
Flange Quantity: 2
-
Voltage Standing Wave Ratio: 1.35
-
Maximum Operating Pressure: 25.0 pounds per square inch gage
-
Waveguide Longer Offset Distance: 41.540 inches
-
End Application: Ct2 mc130h a/c mods
-
Flange Quantity: 2
-
Voltage Standing Wave Ratio: 1.24
-
Insertion Loss In Decibels: 0.26
-
Maximum Operating Pressure: 25.0 pounds per square inch gage
-
Cross Sectional Shape: Internal, rectangular external, rectangular
-
End Application: Hc130 acft
-
Flange Quantity: 2
-
Waveguide Longer Offset Distance: 5.260 inches
-
Waveguide Offset Distance: 3.390 inches
-
End Application: Ct2 mc130h a/c mods
-
Flange Quantity: 2
-
Voltage Standing Wave Ratio: 1.21
-
Insertion Loss In Decibels: 0.26
-
Maximum Operating Pressure: 25.0 pounds per square inch gage
-
Cross Sectional Shape: Internal, rectangular external, rectangular
-
End Application: Mc130-h acft
-
Flange Quantity: 2
-
Waveguide Longer Offset Distance: 7.290 inches
-
Flange Style: Contact type all flanges
93051000
View Part
NSN 5985-01-399-5928
Cross Reference:
93051000-10
-
End Application: F-11a
-
Insertion Loss In Decibels: 40.00
-
Maximum Operating Pressure: 20.0 pounds per square inch gage
-
Special Features: Zero degrees phase shift, power splitter
-
Flexibility: Rigid all tubing segment
93051000-10
View Part
NSN 5985-01-399-5928
Cross Reference:
93051000
-
End Application: F-11a
-
Insertion Loss In Decibels: 40.00
-
Maximum Operating Pressure: 20.0 pounds per square inch gage
-
Special Features: Zero degrees phase shift, power splitter
-
Flexibility: Rigid all tubing segment
-
End Application: F-111a
-
Flange Quantity: 2
-
Insertion Loss In Decibels: 0.50
-
Maximum Operating Pressure: 20.0 pounds per square inch gage
-
Flange Style: Choke type all flanges
-
End Application: F-111a
-
Flange Quantity: 2
-
Insertion Loss In Decibels: 40.00
-
Maximum Operating Pressure: 20.0 pounds per square inch gage
-
Flange Style: Choke type all flanges
933C055103
View Part
NSN 5985-01-093-1620
Cross Reference:
055103
-
Flange Quantity: 2
-
Insertion Loss In Decibels: 1.00
-
Style Designator: Straight type
933C055949
View Part
NSN 5985-01-093-5796
Cross Reference:
060040, 999C060040, TK495009
933C055950
View Part
NSN 5985-01-093-6019
Cross Reference:
055950, 060037, 999C060037, TR495010
-
Cross Sectional Shape: Internal, rectangular external, rectangular
-
Thread Class: 2b first flange all connection facilities
-
Tubing Wall Construction Style: Seamless single tubing segment
-
Flange Quantity: 2
-
Insertion Loss In Decibels: 0.50
933C055951
View Part
NSN 5985-01-108-6395
Cross Reference:
055951, MTP42-503N
-
Cross Sectional Shape: Internal, rectangular external, rectangular
-
Tubing Wall Construction Style: Seamless single tubing segment
-
Flange Quantity: 2
-
Insertion Loss In Decibels: 0.50
-
Waveguide Outside Width: Between 0.497 inches and 0.503 inches
933C055954
View Part
NSN 5985-01-100-7900
Cross Reference:
055954, 060041, 999C060041, TR495012
-
Cross Sectional Shape: Internal, rectangular external, rectangular
-
Thread Class: 2b first flange all connection facilities
-
Bend Angle In Deg: 90.0 single bend e-plane
-
Tubing Wall Construction Style: Seamless single tubing segment
-
Flange Quantity: 2