2b first flange single connection facility thread class, copper alloy all tubing segment and flange material, paint all tubing segment and flange outside surfaces surface treatment, unf first flange single connection facility thread series designator.
Right-hand first flange single connection facility offset bend type.
Includes quality control certificate of conformance.
-
Cross Sectional Shape:
Internal, rectangular external, rectangular
-
Thread Direction:
Right-hand first flange single connection facility
-
Tubing Wall Construction Style:
Seamless single tubing segment
-
Flange Quantity:
2
-
Flange Inside Width:
1.368 inches first flange and 1.376 inches first flange
-
Flange Inside Width:
1.368 inches second flange and 1.376 inches second flange
-
Flange Inside Height:
0.618 inches first flange and 0.626 inches first flange
-
Flange Inside Height:
0.618 inches second flange and 0.626 inches second flange
-
Flange Outside Width:
2.670 inches second flange and 2.710 inches second flange
-
Flange Outside Height:
1.920 inches second flange and 1.960 inches second flange
-
Flange Outside Diameter:
3.110 inches first flange and 3.140 inches first flange
-
Flange Depth:
0.480 inches second flange and 0.520 inches second flange
-
Flange Depth:
0.735 inches first flange and 0.765 inches first flange
-
Flange Connecting Hole Diameter:
0.192 inches second flange single connection facility and 0.200 inches second flange single connection facility
-
Voltage Standing Wave Ratio:
1.10
-
Maximum Operating Pressure:
10.0 pounds per square inch gage
-
Waveguide Outside Width:
Between 1.496 inches and 1.504 inches
-
Thread Size:
0.190 inches first flange single connection facility
-
Waveguide Inside Width:
Between 1.368 inches and 1.376 inches
-
Waveguide Inside Height:
Between 0.618 inches and 0.626 inches
-
Waveguide Outside Height:
Between 0.746 inches and 0.754 inches
-
Flange Connecting Facility And Quantity:
6 threaded hole first flange single connection facility
-
Flange Connecting Facility And Quantity:
8 unthreaded hole second flange single connection facility
-
Flange Style:
Choke type first flange
-
Flange Style:
Contact type second flange
-
Waveguide Length:
Between 18.100 inches and 18.140 inches
-
Waveguide Center To Center Distance:
Between 2.730 inches and 2.770 inches
-
Flexibility:
Rigid single tubing segment
-
Style Designator:
Offset bend type
-
Federal Supply Class (fsc):
Antennas, waveguides, and related equipment
-
National Stock Number (nsn):
5985-01-099-5959