Features
Includes quality control certificate of conformance.
Specifications
-
Operating Tempurature Range:
+110.0/+240.0 degrees fahrenheit
-
End Application:
Lgm30 missile system
-
Inclosure Type:
Encased
-
Power Source:
External
-
Mounting Method:
Bulkhead
-
Maximumlength:
3.070 inches
-
Maximumwidth:
3.750 inches
-
Maximumheight:
5.250 inches
-
Supplementary Features:
Reverse acting
-
Type/model Designation:
T-8000
-
Federal Supply Class (fsc):
Pressure, temperature, and humidity measuring and controlling instruments
-
National Stock Number (nsn):
6685-01-123-1004
-
Special Features:
Pnuematic temperature control which operates with a 25 psig regulated air supply; contains two gages; one to monitor inlet the other to monitor control pressures; has a 0-4 psi sensitivity per deg. F.; temperature adjustment is concealed; surface mounted; ambient temperature operating ranges fromminus 10 deg. F. To +300 deg. F.; temperature included with dial markings of 2 deg. F. Per controling range; furnished with control are 4 1/8 in pipe plugs; 2 elbows; 2 oriface fittings; 2 no 10x1 3/4 in mounting screws; capillary tube and bulb is stainless steel and fully compensated; bulb is 4 in long; capillary tube is 50 ft long