Electromagnetic Relay

2415315

2415315
(NSN) National Stock Number
5945-00-006-1320
Federal Supply Classification
5945 Relays and Solenoids
Item Name Code
32512
Schedule B Code
8536410020
Summary

2a single mounting facility thread class, 3.926 inches maximum overall length, 1.531 inches maximum overall diameter, dustproof environmental protection, 1 winding quantity, 1 coil quantity

DAC HCC DMIL RNCC
1 - - 3
RNVC SADC MSDS RNAAC
2 - - TX
Identification

A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). Includes solenoid and armature types. Excludes:contactor, magnetic; relay, meter movement; relay, motor driven; relay, reed; relay, resonant reed; relay, rotary; and switch, stepping.

INC FIIG Concept Condition
32512 A03300 1 1
Specifications
Thread Class
2a single mounting facility
Details A numeric-alpha designator indicating the pitch diameter tolerance and an external or internal thread.
Overall Length
3.926 inches maximum
Details The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.
Overall Diameter
1.531 inches maximum
Details A measurement of the longest straight line across a circular cross-sectional plane.
Environmental Protection
dustproof
Details The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.
Winding Quantity
1
Details The number of individual /not electrically connected/ windings.
Coil Quantity
1
Details The number of coils included on the item.
Winding Dc Resistance Rating
800.0 ohms nominal single winding
Details The measured opposition to the flow of direct current offered by the item winding.
Duty Type
continuous
Details Indicates the type of duty provided.
Mounting Facility Type And Quantity
3 threaded stud single mounting facility
Details Indicates the type and number of facilities by which the item is mounted.
Nominal Thread Size
0.138 inches single mounting facility
Details A designation that is used for the purpose of general identification of the thread.
Mounting Facility Pattern
ciruclar single mounting facility
Details The general configuration and relative position of the facilities provided for mounting the item.
Nonpile-Up Main Contact Arrangement
1 pole, double throw, one position momentary
Details The designation that identifies the schematic diagram of the electrical configuration of the main nonpile-up contacts including the number of poles or forms.
Time Delay
0.0022 seconds maximum fixed release time
Details The interval for which the item,by design,is purposely delayed between introduction of power into the energizing element and completion of travel of the contact carrier,and/or between interruption of the energizing power and return of the contact carrier to its normal de-energizing position.
Time Delay
0.0040 seconds maximum fixed operate time
Details The interval for which the item,by design,is purposely delayed between introduction of power into the energizing element and completion of travel of the contact carrier,and/or between interruption of the energizing power and return of the contact carrier to its normal de-energizing position.
Operating Voltage Rating And Type At Specified Temp
28.0 volts dc 25 deg celsius single winding
Details The amount and type of voltage required at designated temperature to be applied to the input or energizing element of the item to ensure normal operation of the switching elements.
Main Contact Load Current Rating At Maximum Rated Voltage
1.0 amperes ac resistive load and 1.0 amperes dc resistive load
Details The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.
Main Contact Maximum Voltage Rating In Volts
250.0 ac and 250.0 dc
Details The highest voltage at which the main contacts are rated for normal operation,expressed in volts.
Thread Series Designator
unc single mounting facility
Details A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.
Terminal Type And Quantity
5 pin all functions
Details Indicates the type and number of terminals for providing electrical connection.
Master-Cross Reference List
Part CAGE DAC HCC RNCC RNVC MSDS RNAAC
CR2B1007 71482 1 - 5 9 - TX
2415315 25500 1 - 5 2 - TX
Material and Special Handling
Hazardous material, precious metals, criticality, and electrostatic discharge indicators.
HMIC PMIC ESD/EMI Criticality
N A - -
Freight
Universal / National Freight and Handling Information
UFC HMC LTL LCL
34430 - M P
RVC WCC TCC SHC
- 72D Z 9

What's Included?

  • Certificate of Conformity
  • QC Inspection prior to shipping
  • On time delivery
  • Friendly service to back every order
Manufacturer
NAVAIR AND NAVSEA MANAGED ORIGINAL DESIGN ACTIVITY DWG NOT MATERIAL/PARTS SUPPLIER
CAGE: 10001
WASHINGTON , DC , 20376
UNITED STATES
View Products
FAQs
Frequently asked questions for NSN 5945-00-006-1320
What is the NIIN of the NSN 5945-00-006-1320?
The National Item Identification Number (NIIN) of the NSN 5945-00-006-1320 is 00-006-1320
When the NSN 5945-00-006-1320 was assigned to the Federal Catalog?
It was assigned 52 years ago, on Wed, Jun 21, 1972
Does the NSN 5945-00-006-1320 contain any precious metals?
Does not contain precious metal
Does the NSN 5945-00-006-1320 contain any hazardous material?
No data in HMIRS

Can't Find It

If you didn't find what you need, don't worry, we're here to help! Our team is ready to help you find exactly what you need. Click below to contact us.

Similar Products
Who we are?

At Aerospace Shop, we are dedicated to providing high-quality aerospace components, shop supplies, replacement parts, and tools.

With a commitment to excellence and customer satisfaction, we aim to be your trusted partner in the aerospace industry.

Contact
800 Town and Country Blvd
Houston, TX, 77024
United States
© 2024 Aerospace Shop, Inc. All rights reserved.
Made in USA