Overall Height:
1.150 inches
-
Body Length:
4.020 inches
-
Body Width:
2.020 inches
-
Body Height:
0.900 inches
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
1.683 inches
-
Operating Tempurature Range:
+10.0/+50.0 degrees celsius
-
Reference Frequency Per Function:
62.25 single radio interference any acceptable
-
Reference Frequency Per Function:
2.95 7th radio interference any acceptable
-
Input Impedance Per Function W/load:
2.0 kilohms single band pass
-
Input Impedance Per Function W/load:
2.61 kilohms single low pass
-
Output Impedance Per Function W/source Across Input:
2.0 kilohms single band pass
-
Output Impedance Per Function W/source Across Input:
2.0 kilohms single low pass
-
Principal Circuitry Type Per Function:
Inductance-capacitance-resistance single band pass
-
Principal Circuitry Type Per Function:
Inductance-capacitance-resistance single low pass
-
Mounting Facility Screw Thread Series Designator:
Unc
-
Inclosure Type:
Hermetically sealed
-
Mounting Facility Type And Quantity:
2 threaded hole
-
Insertion Loss At Reference Frequency Per Function In Decibels:
0.35 single low pass
-
Insertion Loss At Reference Frequency Per Function In Decibels:
0.5 single band pass
-
Functional Terminal Type And Quantity:
2 pin ground 3rd function
-
Functional Terminal Type And Quantity:
2 pin output 2nd function
-
Functional Terminal Type And Quantity:
3 pin input 1st function
-
Specified Frequencies Of Discrimination Per Function:
2.50 kilohertz single low pass and 3.40 kilohertz single low pass and 3.75 kilohertz single low pass and 4.30 kilohertz single low pass
-
Specified Frequencies Of Discrimination Per Function:
59.00 kilohertz single band pass and 60.50 kilohertz single band pass and 64.00 kilohertz single band pass and 64.50 kilohertz single band pass
-
Thread Size:
0.112 inches
-
Discrimination At Specificationified Frequencies Per Function In Decibels:
0.35 single low pass and 0.35 single low pass and 30.0 single low pass and 40.0 single low pass
-
Discrimination At Specificationified Frequencies Per Function In Decibels:
25.0 single band pass and 0.5 single band pass and 0.5 single band pass and 54.0 single band pass
-
Style Designator:
Rectangular terminal/terminals on one surface
-
Federal Supply Class (fsc):
Filters and networks
-
National Stock Number (nsn):
5915-00-499-1990