Band Suppression Filter

1185AS156-1

1185AS156-1
(NSN) National Stock Number
5915-01-334-4791
Federal Supply Classification
5915 Filters and Networks
Item Name Code
00210
Schedule B Code
8527995030
Summary

8.000 inches nominal overall length, 8.000 inches nominal body length, 6.000 inches nominal body width, 3.500 inches nominal body height, 0.172 inches nominal unthreaded mounting hole diameter, 6.500 inches nominal distance between centerlines of mounting facilities parallel to body length

DAC HCC DMIL RNCC
A - - 7
RNVC SADC MSDS RNAAC
2 - - TX
Identification

An item designed to suppress frequencies within a specified range (band) and to pass frequencies outside the range (band). Excludes:a single inductance, a single capacitance, or a single resistance. See coil (as modified); capacitor (as modified); and resistor (as modified).

INC FIIG Concept Condition
00210 A047B0 3 1
Specifications
Overall Length
8.000 inches nominal
Details The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.
Body Length
8.000 inches nominal
Details A measurement of the longest dimension of the body,in distinction from width.
Body Width
6.000 inches nominal
Details A measurement taken at right angles to the length of the body,in distinction from thickness.
Body Height
3.500 inches nominal
Details A measurement from the bottom to the top of the body,in distinction from depth.
Unthreaded Mounting Hole Diameter
0.172 inches nominal
Details The length of a straight line which passes through the center of an unthreaded mounting hole,and terminates at the circumference.
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
6.500 inches nominal
Details The distance between centerlines of mounting facilities parallel to the length of the item.
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
5.500 inches nominal
Details The distance between centerlines of mounting facilities parallel to the width of the item.
Operating Temp Range
-55.0 to 85.0 deg celsius
Details The minimum and maximum limits of temperature at which the item is rated for operation.
Reference Frequency Per Function
175.0 kilohertz 1st band suppression 1st function
Details The frequency at which the insertion loss is measured per function,and to which all related attenuation loss measurements are referred.
Reference Frequency Per Function
175.0 kilohertz 2nd band suppression 2nd function
Details The frequency at which the insertion loss is measured per function,and to which all related attenuation loss measurements are referred.
Reference Frequency Per Function
175.0 kilohertz 3rd band suppression 3rd function
Details The frequency at which the insertion loss is measured per function,and to which all related attenuation loss measurements are referred.
Source Impedance Rating Per Function
50.0 ohms 1st band suppression 1st function
Details The total opposition per function,presented by a source of energy to the input terminals of an item.
Source Impedance Rating Per Function
50.0 ohms 2nd band suppression 2nd function
Details The total opposition per function,presented by a source of energy to the input terminals of an item.
Source Impedance Rating Per Function
50.0 ohms 3rd band suppression 3rd function
Details The total opposition per function,presented by a source of energy to the input terminals of an item.
Load Impedance Per Function
50.0 ohms 1st band suppression 1st function
Details The total opposition per function,presented by a load to the output terminals of an item.
Load Impedance Per Function
50.0 ohms 2nd band suppression 2nd function
Details The total opposition per function,presented by a load to the output terminals of an item.
Load Impedance Per Function
50.0 ohms 3rd band suppression 3rd function
Details The total opposition per function,presented by a load to the output terminals of an item.
Principal Circuitry Type Per Function
inductance-capacitance 1st band suppression 1st function
Details Indicates the type of principal circuitry per function interconnected within the item to produce the desired frequency versus attenuation characteristics.
Principal Circuitry Type Per Function
inductance-capacitance 3rd band suppression 3rd function
Details Indicates the type of principal circuitry per function interconnected within the item to produce the desired frequency versus attenuation characteristics.
Principal Circuitry Type Per Function
inductance-capacitance 2nd band suppression 2nd function
Details Indicates the type of principal circuitry per function interconnected within the item to produce the desired frequency versus attenuation characteristics.
Inclosure Type
encased
Details Indicates the type of inclosure provided to coat,cover,protect,or encase the item.
Mounting Facility Type And Quantity
4 unthreaded hole
Details Indicates the type and number of facilities by which the item is mounted.
Insertion Loss At Reference Frequency Per Function In Decibels
3.0 2nd band suppression 2nd function
Details The ratio per function of the power delivered to the load before insertion of the filter to the power delivered to the load after insertion of the filter,expressed in decibels.
Insertion Loss At Reference Frequency Per Function In Decibels
3.0 1st band suppression 1st function
Details The ratio per function of the power delivered to the load before insertion of the filter to the power delivered to the load after insertion of the filter,expressed in decibels.
Insertion Loss At Reference Frequency Per Function In Decibels
3.0 3rd band suppression 3rd function
Details The ratio per function of the power delivered to the load before insertion of the filter to the power delivered to the load after insertion of the filter,expressed in decibels.
Functional Terminal Type And Quantity
3 screw output 2nd function
Details Indicates the functional type and number of terminals providing electrical connection to the item.
Functional Terminal Type And Quantity
3 screw input 1st function
Details Indicates the functional type and number of terminals providing electrical connection to the item.
Specified Frequencies Of Discrimination Per Function
100.00 kilohertz 1st band suppression and 150.00 kilohertz 1st band suppression and 200.00 kilohertz 1st band suppression and 250.00 kilohertz 1st band suppression 1st function
Details The specified frequencies,per function,at which losses in signal strength are,by design or measurement,established in a filter circuit.
Specified Frequencies Of Discrimination Per Function
100.00 kilohertz 3rd band suppression and 150.00 kilohertz 3rd band suppression and 200.00 kilohertz 3rd band suppression and 250.00 kilohertz 3rd band suppression 3rd function
Details The specified frequencies,per function,at which losses in signal strength are,by design or measurement,established in a filter circuit.
Specified Frequencies Of Discrimination Per Function
100.00 kilohertz 2nd band suppression and 150.00 kilohertz 2nd band suppression and 200.00 kilohertz 2nd band suppression and 250.00 kilohertz 2nd band suppression 2nd function
Details The specified frequencies,per function,at which losses in signal strength are,by design or measurement,established in a filter circuit.
Body Material
metal
Details The chemical compound or mechanical mixture properties of which the body is fabricated.
Frequency Band Width Per Function
150.00 kilohertz 1st band suppression and 200.00 kilohertz 1st band suppression 1st function
Details The difference,per function,between the limiting frequencies within which performance,in respect to some characteristic,falls within specified limits.
Frequency Band Width Per Function
150.00 kilohertz 2nd band suppression and 200.00 kilohertz 2nd band suppression 2nd function
Details The difference,per function,between the limiting frequencies within which performance,in respect to some characteristic,falls within specified limits.
Frequency Band Width Per Function
150.00 kilohertz 3rd band suppression and 200.00 kilohertz 3rd band suppression 3rd function
Details The difference,per function,between the limiting frequencies within which performance,in respect to some characteristic,falls within specified limits.
Discrimination At Specified Frequencies Per Function In Decibels
3.0 minimum 1st band suppression and 60.0 maximum 1st band suppression 1st function
Details The algebraic difference between the insertion loss at a specified frequency and the insertion loss at the reference frequency per function,expressed in decibels.
Discrimination At Specified Frequencies Per Function In Decibels
3.0 minimum 3rd band suppression and 60.0 maximum 3rd band suppression 3rd function
Details The algebraic difference between the insertion loss at a specified frequency and the insertion loss at the reference frequency per function,expressed in decibels.
Discrimination At Specified Frequencies Per Function In Decibels
3.0 minimum 2nd band suppression and 60.0 maximum 2nd band suppression 2nd function
Details The algebraic difference between the insertion loss at a specified frequency and the insertion loss at the reference frequency per function,expressed in decibels.
Special Features
three filtered functions; one unfiltered function
Details Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification on one or more other functions.
Style Designator
rectangular terminal/terminals on opposite surfaces
Details The style designation indicating the configuration that most nearly corresponds to the appearance of the item.
Specification/Standard Data
30003-1185as156 manufacturers specification control
Details The document designator of the specification or standard which established the item of supply.
Master-Cross Reference List
Part CAGE DAC HCC RNCC RNVC MSDS RNAAC
401004 50545 5 - 3 2 - TX
Material and Special Handling
Hazardous material, precious metals, criticality, and electrostatic discharge indicators.
HMIC PMIC ESD/EMI Criticality
P A - -
Freight
Universal / National Freight and Handling Information
UFC HMC LTL LCL
58500 - P -
RVC WCC TCC SHC
- 72D Z 9

What's Included?

  • Certificate of Conformity
  • QC Inspection prior to shipping
  • On time delivery
  • Friendly service to back every order
Manufacturer
NAVAL AIR SYSTEMS COMMAND MANAGED ORIGINAL DESIGN ACTIVITY NOT MATERIAL/PARTS SUPPLIER
CAGE: 30003
PATUXENT RIVER , MD , 20670-1547
UNITED STATES
View Products
FAQs
Frequently asked questions for NSN 5915-01-334-4791
What is the NIIN of the NSN 5915-01-334-4791?
The National Item Identification Number (NIIN) of the NSN 5915-01-334-4791 is 01-334-4791
When the NSN 5915-01-334-4791 was assigned to the Federal Catalog?
It was assigned 33 years ago, on Sat, Feb 23, 1991
Does the NSN 5915-01-334-4791 contain any precious metals?
Does not contain precious metal
Does the NSN 5915-01-334-4791 contain any hazardous material?
No information in HMIRS

Can't Find It

If you didn't find what you need, don't worry, we're here to help! Our team is ready to help you find exactly what you need. Click below to contact us.

Similar Products
Who we are?

At Aerospace Shop, we are dedicated to providing high-quality aerospace components, shop supplies, replacement parts, and tools.

With a commitment to excellence and customer satisfaction, we aim to be your trusted partner in the aerospace industry.

Contact
800 Town and Country Blvd
Houston, TX, 77024
United States
© 2024 Aerospace Shop, Inc. All rights reserved.
Made in USA