Overall Height:
5.630 inches
-
Body Length:
9.500 inches
-
Body Width:
7.000 inches
-
Body Height:
3.500 inches
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
8.370 inches
-
Vibration Resistance Range In Hertz:
+10.0 to 500.0
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
6.250 inches
-
Operating Tempurature Range:
-65.0 to 85.0 degrees celsius
-
Source Impedance Rating Per Function:
50.0 ohms 1st radio interference 1st function
-
Source Impedance Rating Per Function:
50.0 ohms 2nd radio interference 2nd function
-
Source Impedance Rating Per Function:
50.0 ohms 4th radio interference 4th function
-
Source Impedance Rating Per Function:
50.0 ohms 3rd radio interference 3rd function
-
Load Impedance Per Function:
50.0 ohms 1st radio interference 1st function
-
Load Impedance Per Function:
50.0 ohms 2nd radio interference 2nd function
-
Load Impedance Per Function:
50.0 ohms 3rd radio interference 3rd function
-
Load Impedance Per Function:
50.0 ohms 4th radio interference 4th function
-
Power Line Frequency Rating Per Function In Hertz:
400.0 1st radio interference 1st function
-
Power Line Frequency Rating Per Function In Hertz:
400.0 2nd radio interference 2nd function
-
Power Line Frequency Rating Per Function In Hertz:
400.0 3rd radio interference 3rd function
-
Power Line Frequency Rating Per Function In Hertz:
400.0 4th radio interference 4th function
-
Operating Current Rating Per Function In Amps:
55.0 3rd radio interference 3rd function
-
Operating Current Rating Per Function In Amps:
55.0 4th radio interference 4th function
-
Operating Current Rating Per Function In Amps:
55.0 2nd radio interference 2nd function
-
Operating Current Rating Per Function In Amps:
55.0 1st radio interference 1st function
-
Maximum Voltage Drop Per Function:
2.5 volts ac 1st radio interference and 4.0 volts dc 1st radio interference 1st function
-
Maximum Voltage Drop Per Function:
2.5 volts ac 3rd radio interference and 4.0 volts dc 3rd radio interference 3rd function
-
Maximum Voltage Drop Per Function:
2.5 volts ac 2nd radio interference and 4.0 volts dc 2nd radio interference 2nd function
-
Maximum Voltage Drop Per Function:
2.5 volts ac 4th radio interference and 4.0 volts dc 4th radio interference 4th function
-
Principal Circuitry Type Per Function:
Inductance-capacitance 1st radio interference 1st function
-
Principal Circuitry Type Per Function:
Inductance-capacitance 2nd radio interference 2nd function
-
Principal Circuitry Type Per Function:
Inductance-capacitance 4th radio interference 4th function
-
Principal Circuitry Type Per Function:
Inductance-capacitance 3rd radio interference 3rd function
-
Maximum Tempurature Rise:
25.0 degrees celsius
-
Mounting Facility Screw Thread Series Designator:
Unf
-
Inclosure Type:
Hermetically sealed
-
Mounting Facility Type And Quantity:
8 threaded hole all functions
-
Functional Terminal Type And Quantity:
4 threaded stud input 1st function
-
Functional Terminal Type And Quantity:
4 threaded stud output 2nd function
-
Maximum Dielectric Withstanding Ac Rms Voltage:
1.2 kilovolts at sea level
-
Operating Voltage Rating And Type Per Function:
250.0 volts ac 1st radio interference and 400.0 volts dc 1st radio interference 1st function
-
Operating Voltage Rating And Type Per Function:
250.0 volts ac 2nd radio interference and 400.0 volts dc 2nd radio interference 2nd function
-
Operating Voltage Rating And Type Per Function:
250.0 volts ac 3rd radio interference and 400.0 volts dc 3rd radio interference 3rd function
-
Operating Voltage Rating And Type Per Function:
250.0 volts ac 4th radio interference and 400.0 volts dc 4th radio interference 4th function
-
Thread Size:
0.190 inches
-
Body Material:
Metal
-
Body Surface Treatment:
Tin
-
Style Designator:
Rectangular terminal/terminals on opposite surfaces
-
Federal Supply Class (fsc):
Filters and networks
-
National Stock Number (nsn):
5915-01-226-9977