Overall Height:
5.307 inches
-
Body Length:
2.812 inches
-
Body Width:
2.375 inches
-
Body Height:
3.500 inches
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
2.437 inches
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
1.500 inches
-
Operating Tempurature Range:
-55.0/+125.0 degrees celsius
-
Average Life Rating In Hours:
250.0
-
Source Impedance Rating Per Function:
50.0 ohms 1st radio interference
-
Source Impedance Rating Per Function:
50.0 ohms 2nd radio interference
-
Source Impedance Rating Per Function:
50.0 ohms 5th radio interference
-
Source Impedance Rating Per Function:
50.0 ohms 6th radio interference
-
Source Impedance Rating Per Function:
50.0 ohms 3rd radio interference
-
Source Impedance Rating Per Function:
50.0 ohms 4th radio interference
-
Load Impedance Per Function:
50.0 ohms 1st radio interference
-
Load Impedance Per Function:
50.0 ohms 3rd radio interference
-
Load Impedance Per Function:
50.0 ohms 2nd radio interference
-
Load Impedance Per Function:
50.0 ohms 6th radio interference
-
Load Impedance Per Function:
50.0 ohms 4th radio interference
-
Load Impedance Per Function:
50.0 ohms 5th radio interference
-
Power Line Frequency Rating Per Function In Hertz:
400.0 2nd radio interference
-
Power Line Frequency Rating Per Function In Hertz:
400.0 3rd radio interference
-
Operating Current Rating Per Function In Amps:
0.015 4th radio interference
-
Operating Current Rating Per Function In Amps:
0.05 2nd radio interference
-
Operating Current Rating Per Function In Amps:
0.05 3rd radio interference
-
Operating Current Rating Per Function In Amps:
0.1 1st radio interference
-
Operating Current Rating Per Function In Amps:
0.1 5th radio interference
-
Operating Current Rating Per Function In Amps:
0.1 6th radio interference
-
Maximum Voltage Drop Per Function:
250.0 millivolts dc 1st radio interference
-
Maximum Voltage Drop Per Function:
250.0 millivolts dc 2nd radio interference
-
Maximum Voltage Drop Per Function:
250.0 millivolts dc 3rd radio interference
-
Maximum Voltage Drop Per Function:
250.0 millivolts dc 4th radio interference
-
Maximum Voltage Drop Per Function:
250.0 millivolts dc 5th radio interference
-
Maximum Voltage Drop Per Function:
250.0 millivolts dc 6th radio interference
-
Maximum Tempurature Rise:
25.0 degrees celsius
-
Mounting Facility Screw Thread Series Designator:
Unc
-
Inclosure Type:
Encased
-
Mounting Facility Type And Quantity:
4 threaded hole
-
Mounting Facility Type And Quantity:
1 connector
-
Functional Terminal Type And Quantity:
1 connector, receptacle input 1st function
-
Functional Terminal Type And Quantity:
21 tab, solder lug output 2nd function
-
Operating Voltage Rating And Type Per Function:
200.0 volts dc 1st radio interference 1st function
-
Operating Voltage Rating And Type Per Function:
200.0 volts dc 5th radio interference 5th function
-
Operating Voltage Rating And Type Per Function:
200.0 volts dc 6th radio interference 6th function
-
Operating Voltage Rating And Type Per Function:
200.0 volts dc 4th radio interference 4th function
-
Operating Voltage Rating And Type Per Function:
25.0 volts ac 3rd radio interference 3rd function and 200.0 volts dc 3rd radio interference 3rd function
-
Operating Voltage Rating And Type Per Function:
115.0 volts ac 2nd radio interference 2nd function and 300.0 volts dc 2nd radio interference 2nd function
-
Thread Size:
0.138 inches
-
Body Material:
Metal
-
Maximum Dielectric Withstanding Dc Voltage:
600.0 volts at sea level
-
Body Surface Treatment:
Tin
-
Unpackaged Unit Weight:
35.000 ounces
-
Style Designator:
Rectangular terminal/terminals on opposite surfaces
-
Federal Supply Class (fsc):
Filters and networks
-
National Stock Number (nsn):
5915-00-878-3522
-
Special Features:
21 functions