Overall Height:
3.734 inches
-
Body Length:
5.500 inches
-
Body Width:
4.900 inches
-
Body Height:
3.000 inches
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
4.875 inches
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
4.275 inches
-
Operating Tempurature Range:
-55.0/+95.0 degrees celsius
-
Source Impedance Rating Per Function:
50.0 ohms 1st radio interference
-
Source Impedance Rating Per Function:
50.0 ohms 2nd radio interference
-
Source Impedance Rating Per Function:
50.0 ohms 5th radio interference
-
Source Impedance Rating Per Function:
50.0 ohms 6th radio interference
-
Source Impedance Rating Per Function:
50.0 ohms 3rd radio interference
-
Source Impedance Rating Per Function:
50.0 ohms 4th radio interference
-
Load Impedance Per Function:
50.0 ohms 1st radio interference
-
Load Impedance Per Function:
50.0 ohms 3rd radio interference
-
Load Impedance Per Function:
50.0 ohms 2nd radio interference
-
Load Impedance Per Function:
50.0 ohms 6th radio interference
-
Load Impedance Per Function:
50.0 ohms 4th radio interference
-
Load Impedance Per Function:
50.0 ohms 5th radio interference
-
Power Line Frequency Rating Per Function In Hertz:
400.0 1st radio interference
-
Power Line Frequency Rating Per Function In Hertz:
400.0 2nd radio interference
-
Power Line Frequency Rating Per Function In Hertz:
400.0 3rd radio interference
-
Power Line Frequency Rating Per Function In Hertz:
400.0 4th radio interference
-
Power Line Frequency Rating Per Function In Hertz:
400.0 5th radio interference
-
Operating Current Rating Per Function In Amps:
6.0 1st radio interference
-
Operating Current Rating Per Function In Amps:
6.0 2nd radio interference
-
Operating Current Rating Per Function In Amps:
6.0 3rd radio interference
-
Operating Current Rating Per Function In Amps:
6.0 4th radio interference
-
Operating Current Rating Per Function In Amps:
0.5 5th radio interference
-
Operating Current Rating Per Function In Amps:
5.0 6th radio interference
-
Maximum Voltage Drop Per Function:
10.0 millivolts ac 5th radio interference
-
Maximum Voltage Drop Per Function:
150.0 millivolts dc 6th radio interference
-
Maximum Voltage Drop Per Function:
20.0 millivolts ac 4th radio interference
-
Maximum Voltage Drop Per Function:
210.0 millivolts ac 3rd radio interference
-
Maximum Voltage Drop Per Function:
210.0 millivolts ac 1st radio interference
-
Maximum Voltage Drop Per Function:
210.0 millivolts ac 2nd radio interference
-
Maximum Tempurature Rise:
40.0 degrees celsius
-
Mounting Facility Screw Thread Series Designator:
Unc
-
Inclosure Type:
Encased
-
Mounting Facility Type And Quantity:
4 threaded hole
-
Functional Terminal Type And Quantity:
1 pin ground 3rd function
-
Functional Terminal Type And Quantity:
18 pin output 2nd function
-
Functional Terminal Type And Quantity:
2 connector, receptacle input 1st function and 2 pin input 1st function
-
Operating Voltage Rating And Type Per Function:
168.0 volts ac 1st radio interference 1st function
-
Operating Voltage Rating And Type Per Function:
168.0 volts ac 2nd radio interference 2nd function
-
Operating Voltage Rating And Type Per Function:
168.0 volts ac 3rd radio interference 3rd function
-
Operating Voltage Rating And Type Per Function:
168.0 volts ac 5th radio interference 5th function
-
Operating Voltage Rating And Type Per Function:
28.0 volts dc 6th radio interference 6th function
-
Operating Voltage Rating And Type Per Function:
50.0 volts ac 4th radio interference 4th function
-
Thread Size:
0.164 inches
-
Body Material:
Aluminum
-
Body Surface Treatment:
Tin
-
Unpackaged Unit Weight:
2.980 pounds
-
Style Designator:
Rectangular terminal/terminals on two surfaces
-
Federal Supply Class (fsc):
Filters and networks
-
National Stock Number (nsn):
5915-01-148-3295
-
Special Features:
18 functions; 26 dummy terminals