Overall Height:
16.250 inches
-
Overall Width:
2.620 inches
-
Body Length:
2.000 inches
-
Body Width:
4.000 inches
-
Unthreaded Mounting Hole Diameter:
0.209 inches
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
2.500 inches
-
Vibration Resistance Range In Hertz:
+5.0/+500.0
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
1.250 inches
-
Operating Tempurature Range:
-55.0/+100.0 degrees celsius
-
Source Impedance Rating Per Function:
50.0 ohms 1st radio interference
-
Source Impedance Rating Per Function:
50.0 ohms 2nd radio interference
-
Source Impedance Rating Per Function:
50.0 ohms 5th radio interference
-
Source Impedance Rating Per Function:
50.0 ohms 3rd radio interference
-
Source Impedance Rating Per Function:
50.0 ohms 4th radio interference
-
Load Impedance Per Function:
50.0 ohms 1st radio interference
-
Load Impedance Per Function:
50.0 ohms 3rd radio interference
-
Load Impedance Per Function:
50.0 ohms 2nd radio interference
-
Load Impedance Per Function:
50.0 ohms 4th radio interference
-
Load Impedance Per Function:
50.0 ohms 5th radio interference
-
Power Line Frequency Rating Per Function In Hertz:
400.0 1st radio interference
-
Power Line Frequency Rating Per Function In Hertz:
400.0 2nd radio interference
-
Power Line Frequency Rating Per Function In Hertz:
400.0 3rd radio interference
-
Operating Current Rating Per Function In Amps:
0.05 4th radio interference
-
Operating Current Rating Per Function In Amps:
0.1 5th radio interference
-
Operating Current Rating Per Function In Amps:
2.0 2nd radio interference
-
Operating Current Rating Per Function In Amps:
2.0 1st radio interference
-
Operating Current Rating Per Function In Amps:
2.0 3rd radio interference
-
Maximum Voltage Drop Per Function:
1.5 volts ac 1st radio interference
-
Maximum Voltage Drop Per Function:
1.5 volts ac 2nd radio interference
-
Maximum Voltage Drop Per Function:
1.5 volts ac 3rd radio interference
-
Maximum Voltage Drop Per Function:
500.0 millivolts dc 4th radio interference
-
Maximum Voltage Drop Per Function:
500.0 millivolts dc 5th radio interference
-
Principal Circuitry Type Per Function:
Inductance-capacitance 1st radio interference
-
Principal Circuitry Type Per Function:
Inductance-capacitance 2nd radio interference
-
Principal Circuitry Type Per Function:
Inductance-capacitance 4th radio interference
-
Principal Circuitry Type Per Function:
Inductance-capacitance 3rd radio interference
-
Principal Circuitry Type Per Function:
Inductance-capacitance 5th radio interference
-
Inclosure Type:
Hermetically sealed
-
Mounting Facility Type And Quantity:
4 unthreaded hole
-
Functional Terminal Type And Quantity:
5 wire hook output 2nd function
-
Functional Terminal Type And Quantity:
5 wire lead input 1st function
-
Maximum Dielectric Withstanding Ac Rms Voltage:
600.0 volts at sea level
-
Operating Voltage Rating And Type Per Function:
300.0 volts dc 4th radio interference 4th function
-
Operating Voltage Rating And Type Per Function:
100.0 volts dc 5th radio interference 5th function
-
Operating Voltage Rating And Type Per Function:
115.0 volts ac 1st radio interference 1st function
-
Operating Voltage Rating And Type Per Function:
115.0 volts ac 2nd radio interference 2nd function
-
Operating Voltage Rating And Type Per Function:
115.0 volts ac 3rd radio interference 3rd function
-
Style Designator:
Rectangular terminal/terminals on opposite surfaces
-
Federal Supply Class (fsc):
Filters and networks
-
National Stock Number (nsn):
5915-00-952-0591