Overall Height:
0.965 inches
-
Body Length:
1.600 inches
-
Body Width:
0.500 inches
-
Body Height:
0.465 inches
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
1.940 inches
-
Vibration Resistance Range In Hertz:
+10.0/+2000.0
-
Operating Tempurature Range:
-55.0/+85.0 degrees celsius
-
Operating Tempurature Range:
-55.0 to 85.0 degrees celsius
-
Source Impedance Rating Per Function:
50.0 ohms 1st radio interference
-
Source Impedance Rating Per Function:
50.0 ohms 2nd radio interference
-
Source Impedance Rating Per Function:
50.0 ohms 5th radio interference
-
Source Impedance Rating Per Function:
50.0 ohms 6th radio interference
-
Source Impedance Rating Per Function:
50.0 ohms 3rd radio interference
-
Source Impedance Rating Per Function:
50.0 ohms 4th radio interference
-
Source Impedance Rating Per Function:
50.0 ohms 4th radio interference 4th function
-
Source Impedance Rating Per Function:
50.0 ohms 2nd radio interference 2nd function
-
Load Impedance Per Function:
50.0 ohms 1st radio interference
-
Load Impedance Per Function:
50.0 ohms 3rd radio interference
-
Load Impedance Per Function:
50.0 ohms 2nd radio interference
-
Load Impedance Per Function:
50.0 ohms 6th radio interference
-
Load Impedance Per Function:
50.0 ohms 4th radio interference
-
Load Impedance Per Function:
50.0 ohms 5th radio interference
-
Load Impedance Per Function:
50.0 ohms 1st radio interference 1st function
-
Load Impedance Per Function:
50.0 ohms 5th radio interference 5th function
-
Load Impedance Per Function:
50.0 ohms 3rd radio interference 3rd function
-
Operating Current Rating Per Function In Amps:
5.0 1st radio interference
-
Operating Current Rating Per Function In Amps:
5.0 4th radio interference
-
Operating Current Rating Per Function In Amps:
5.0 5th radio interference
-
Operating Current Rating Per Function In Amps:
5.0 6th radio interference
-
Operating Current Rating Per Function In Amps:
5.0 2nd radio interference
-
Operating Current Rating Per Function In Amps:
5.0 3rd radio interference
-
Operating Current Rating Per Function In Amps:
5.0 1st radio interference 1st function
-
Operating Current Rating Per Function In Amps:
5.0 3rd radio interference 3rd function
-
Operating Current Rating Per Function In Amps:
5.0 5th radio interference 5th function
-
Distance Between Mounting Surface And Lower End:
0.530 inches
-
Mounting Facility Screw Thread Series Designator:
Unc
-
Inclosure Type:
Encased
-
Mounting Facility Type And Quantity:
2 threaded hole
-
Functional Terminal Type And Quantity:
9 pin output 2nd function
-
Functional Terminal Type And Quantity:
9 pin input 1st function
-
Operating Voltage Rating And Type Per Function:
200.0 volts dc 2nd radio interference 2nd function
-
Operating Voltage Rating And Type Per Function:
200.0 volts dc 5th radio interference 5th function
-
Operating Voltage Rating And Type Per Function:
200.0 volts dc 6th radio interference 6th function
-
Operating Voltage Rating And Type Per Function:
200.0 volts dc 3rd radio interference 3rd function
-
Operating Voltage Rating And Type Per Function:
200.0 volts dc 4th radio interference 4th function
-
Operating Voltage Rating And Type Per Function:
300.0 volts dc 1st radio interference 1st function
-
Thread Size:
0.112 inches
-
Body Material:
Aluminum
-
Maximum Dielectric Withstanding Dc Voltage:
600.0 volts at sea level
-
Style Designator:
Rectangular terminal/terminals on opposite surfaces
-
Federal Supply Class (fsc):
Filters and networks
-
National Stock Number (nsn):
5915-00-073-2618
-
Special Features:
Consists of 9 functions