Overall Height:
3.040 inches
-
Body Length:
2.700 inches
-
Body Width:
1.300 inches
-
Body Height:
2.600 inches
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
2.125 inches
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
2.000 inches
-
Operating Tempurature Range:
-54.0/+110.0 degrees celsius
-
Source Impedance Rating Per Function:
50.0 ohms 1st radio interference
-
Source Impedance Rating Per Function:
50.0 ohms 2nd radio interference
-
Source Impedance Rating Per Function:
50.0 ohms 5th radio interference
-
Source Impedance Rating Per Function:
50.0 ohms 3rd radio interference
-
Source Impedance Rating Per Function:
50.0 ohms 4th radio interference
-
Load Impedance Per Function:
50.0 ohms 1st radio interference
-
Load Impedance Per Function:
50.0 ohms 3rd radio interference
-
Load Impedance Per Function:
50.0 ohms 2nd radio interference
-
Load Impedance Per Function:
50.0 ohms 4th radio interference
-
Load Impedance Per Function:
50.0 ohms 5th radio interference
-
Power Line Frequency Rating Per Function In Hertz:
400.0 1st radio interference
-
Power Line Frequency Rating Per Function In Hertz:
400.0 2nd radio interference
-
Power Line Frequency Rating Per Function In Hertz:
400.0 3rd radio interference
-
Power Line Frequency Rating Per Function In Hertz:
400.0 4th radio interference
-
Operating Current Rating Per Function In Amps:
0.5 1st radio interference
-
Operating Current Rating Per Function In Amps:
0.5 2nd radio interference
-
Operating Current Rating Per Function In Amps:
0.5 3rd radio interference
-
Operating Current Rating Per Function In Amps:
0.5 4th radio interference
-
Operating Current Rating Per Function In Amps:
0.5 5th radio interference
-
Maximum Voltage Drop Per Function:
1.0 volts ac 2nd radio interference
-
Maximum Voltage Drop Per Function:
1.0 volts ac 1st radio interference
-
Maximum Voltage Drop Per Function:
1.0 volts ac 3rd radio interference
-
Maximum Voltage Drop Per Function:
1.0 volts ac 4th radio interference
-
Maximum Voltage Drop Per Function:
1.0 volts ac 5th radio interference
-
Input Terminal Manufacturer Code:
35351
-
Input Terminal Identification:
Ms27471y1d35p
-
Mounting Facility Screw Thread Series Designator:
Unc
-
Inclosure Type:
Hermetically sealed
-
Mounting Facility Type And Quantity:
4 threaded hole
-
Functional Terminal Type And Quantity:
1 connector, receptacle input-ground 1st function
-
Functional Terminal Type And Quantity:
1 tab, solder lug ground 3rd function
-
Functional Terminal Type And Quantity:
5 tab, solder lug output 2nd function
-
Operating Voltage Rating And Type Per Function:
115.0 volts ac 1st radio interference 1st function
-
Operating Voltage Rating And Type Per Function:
115.0 volts ac 2nd radio interference 2nd function
-
Operating Voltage Rating And Type Per Function:
115.0 volts ac 3rd radio interference 3rd function
-
Operating Voltage Rating And Type Per Function:
115.0 volts ac 4th radio interference 4th function
-
Operating Voltage Rating And Type Per Function:
115.0 volts ac 5th radio interference 5th function
-
Thread Size:
0.112 inches
-
Unpackaged Unit Weight:
13.000 ounces
-
Style Designator:
Rectangular terminal/terminals on one surface
-
Federal Supply Class (fsc):
Filters and networks
-
National Stock Number (nsn):
5915-01-096-6263