Features

2.750 inches nominal overall length.

2.690" overall width rectangular terminal/terminals on opposite surfaces.

Includes quality control certificate of conformance.

Specifications

  • Overall Height:
    1.120 inches
  • Overall Width:
    2.690 inches
  • Body Length:
    2.000 inches
  • Body Width:
    2.000 inches
  • Unthreaded Mounting Hole Diameter:
    0.190 inches
  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
    2.370 inches
  • Operating Tempurature Range:
    -65.0/+125.0 degrees celsius
  • Operating Tempurature Range:
    -65.0 to 125.0 degrees celsius
  • Average Life Rating In Hours:
    1000.0
  • Source Impedance Rating Per Function:
    50.0 ohms 1st radio interference
  • Source Impedance Rating Per Function:
    50.0 ohms 2nd radio interference
  • Source Impedance Rating Per Function:
    50.0 ohms 3rd radio interference
  • Source Impedance Rating Per Function:
    50.0 ohms 4th radio interference
  • Source Impedance Rating Per Function:
    50.0 ohms 1st radio interference 1st function
  • Source Impedance Rating Per Function:
    50.0 ohms 3rd radio interference 3rd function
  • Load Impedance Per Function:
    50.0 ohms 1st radio interference
  • Load Impedance Per Function:
    50.0 ohms 3rd radio interference
  • Load Impedance Per Function:
    50.0 ohms 2nd radio interference
  • Load Impedance Per Function:
    50.0 ohms 4th radio interference
  • Load Impedance Per Function:
    50.0 ohms 1st radio interference 1st function
  • Load Impedance Per Function:
    50.0 ohms 3rd radio interference 3rd function
  • Power Line Frequency Rating Per Function In Hertz:
    400.0 1st radio interference
  • Power Line Frequency Rating Per Function In Hertz:
    400.0 2nd radio interference
  • Power Line Frequency Rating Per Function In Hertz:
    400.0 3rd radio interference
  • Power Line Frequency Rating Per Function In Hertz:
    400.0 4th radio interference
  • Power Line Frequency Rating Per Function In Hertz:
    400.0 2nd radio interference 2nd function
  • Power Line Frequency Rating Per Function In Hertz:
    400.0 4th radio interference 4th function
  • Operating Current Rating Per Function In Amps:
    10.0 1st radio interference
  • Operating Current Rating Per Function In Amps:
    10.0 2nd radio interference
  • Operating Current Rating Per Function In Amps:
    10.0 3rd radio interference
  • Operating Current Rating Per Function In Amps:
    10.0 4th radio interference
  • Operating Current Rating Per Function In Amps:
    10.0 2nd radio interference 2nd function
  • Operating Current Rating Per Function In Amps:
    10.0 4th radio interference 4th function
  • Maximum Voltage Drop Per Function:
    2.0 volts ac 1st radio interference
  • Maximum Voltage Drop Per Function:
    2.0 volts ac 4th radio interference
  • Maximum Voltage Drop Per Function:
    2.0 volts ac 2nd radio interference
  • Maximum Voltage Drop Per Function:
    2.0 volts ac 3rd radio interference
  • Maximum Voltage Drop Per Function:
    2.0 volts ac 3rd radio interference 3rd function
  • Principal Circuitry Type Per Function:
    Inductance-capacitance 1st radio interference
  • Principal Circuitry Type Per Function:
    Inductance-capacitance 2nd radio interference
  • Principal Circuitry Type Per Function:
    Inductance-capacitance 4th radio interference
  • Principal Circuitry Type Per Function:
    Inductance-capacitance 3rd radio interference
  • Principal Circuitry Type Per Function:
    Inductance-capacitance 1st radio interference 1st function
  • Principal Circuitry Type Per Function:
    Inductance-capacitance 3rd radio interference 3rd function
  • Inclosure Type:
    Encased
  • Mounting Facility Type And Quantity:
    2 unthreaded hole
  • Functional Terminal Type And Quantity:
    4 tab, solder lug input 1st function
  • Functional Terminal Type And Quantity:
    4 tab, solder lug output 2nd function
  • Operating Voltage Rating And Type Per Function:
    132.0 volts ac 1st radio interference 1st function
  • Operating Voltage Rating And Type Per Function:
    132.0 volts ac 2nd radio interference 2nd function
  • Operating Voltage Rating And Type Per Function:
    132.0 volts ac 3rd radio interference 3rd function
  • Operating Voltage Rating And Type Per Function:
    132.0 volts ac 4th radio interference 4th function
  • Maximum Dielectric Withstanding Dc Voltage:
    400.0 volts at sea level
  • Style Designator:
    Rectangular terminal/terminals on opposite surfaces
  • Federal Supply Class (fsc):
    Filters and networks
  • National Stock Number (nsn):
    5915-00-145-3605