14.000 inches nominal overall length.
8.000" overall width rectangular terminal/terminals on opposite surfaces.
Includes quality control certificate of conformance.
-
Overall Height:
3.500 inches
-
Overall Width:
8.000 inches
-
Body Length:
14.000 inches
-
Body Width:
6.000 inches
-
Unthreaded Mounting Hole Diameter:
Between 0.255 inches and 0.275 inches
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
13.000 inches
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
7.000 inches
-
Operating Tempurature Range:
+0.0/+85.0 degrees celsius
-
Source Impedance Rating Per Function:
50.0 ohms 1st radio interference
-
Source Impedance Rating Per Function:
50.0 ohms 2nd radio interference
-
Source Impedance Rating Per Function:
50.0 ohms 3rd radio interference
-
Load Impedance Per Function:
50.0 ohms 1st radio interference
-
Load Impedance Per Function:
50.0 ohms 3rd radio interference
-
Load Impedance Per Function:
50.0 ohms 2nd radio interference
-
Power Line Frequency Rating Per Function In Hertz:
60.0 1st radio interference
-
Power Line Frequency Rating Per Function In Hertz:
60.0 2nd radio interference
-
Power Line Frequency Rating Per Function In Hertz:
60.0 3rd radio interference
-
Operating Current Rating Per Function In Amps:
50.0 1st radio interference
-
Operating Current Rating Per Function In Amps:
50.0 2nd radio interference
-
Operating Current Rating Per Function In Amps:
50.0 3rd radio interference
-
Maximum Voltage Drop Per Function:
4.4 volts ac 1st radio interference
-
Maximum Voltage Drop Per Function:
4.4 volts ac 2nd radio interference
-
Maximum Voltage Drop Per Function:
4.4 volts ac 3rd radio interference
-
Inclosure Type:
Hermetically sealed
-
Mounting Facility Type And Quantity:
8 unthreaded hole
-
Functional Terminal Type And Quantity:
3 threaded stud output 2nd function
-
Functional Terminal Type And Quantity:
3 threaded stud input 1st function
-
Operating Voltage Rating And Type Per Function:
250.0 volts ac 1st radio interference 1st function and 600.0 volts dc 1st radio interference 1st function
-
Operating Voltage Rating And Type Per Function:
250.0 volts ac 2nd radio interference 2nd function and 600.0 volts dc 2nd radio interference 2nd function
-
Operating Voltage Rating And Type Per Function:
250.0 volts ac 3rd radio interference 3rd function and 600.0 volts dc 3rd radio interference 3rd function
-
Body Material:
Metal
-
Body Surface Treatment:
Tin
-
Unpackaged Unit Weight:
25.000 pounds
-
Style Designator:
Rectangular terminal/terminals on opposite surfaces
-
Federal Supply Class (fsc):
Filters and networks
-
National Stock Number (nsn):
5915-00-622-0390
-
Special Features:
Terminals on @opposite ends of filter