Overall Height:
1.213 inches
-
Operating Tempurature Range:
-65.0/+160.0 degrees fahrenheit
-
Source Impedance Rating Per Function:
50.0 ohms 1st radio interference
-
Source Impedance Rating Per Function:
50.0 ohms 2nd radio interference
-
Source Impedance Rating Per Function:
50.0 ohms 5th radio interference
-
Source Impedance Rating Per Function:
50.0 ohms 6th radio interference
-
Source Impedance Rating Per Function:
50.0 ohms 3rd radio interference
-
Source Impedance Rating Per Function:
50.0 ohms 4th radio interference
-
Load Impedance Per Function:
50.0 ohms 1st radio interference
-
Load Impedance Per Function:
50.0 ohms 3rd radio interference
-
Load Impedance Per Function:
50.0 ohms 2nd radio interference
-
Load Impedance Per Function:
50.0 ohms 6th radio interference
-
Load Impedance Per Function:
50.0 ohms 4th radio interference
-
Load Impedance Per Function:
50.0 ohms 5th radio interference
-
Operating Current Rating Per Function In Amps:
0.1 5th radio interference
-
Operating Current Rating Per Function In Amps:
0.3 3rd radio interference
-
Operating Current Rating Per Function In Amps:
0.6 4th radio interference
-
Operating Current Rating Per Function In Amps:
0.6 6th radio interference
-
Operating Current Rating Per Function In Amps:
3.0 1st radio interference
-
Operating Current Rating Per Function In Amps:
3.0 2nd radio interference
-
Principal Circuitry Type Per Function:
Inductance-capacitance 1st radio interference
-
Principal Circuitry Type Per Function:
Inductance-capacitance 2nd radio interference
-
Principal Circuitry Type Per Function:
Inductance-capacitance 4th radio interference
-
Principal Circuitry Type Per Function:
Inductance-capacitance 3rd radio interference
-
Principal Circuitry Type Per Function:
Inductance-capacitance 5th radio interference
-
Principal Circuitry Type Per Function:
Inductance-capacitance 6th radio interference
-
Mounting Facility Screw Thread Series Designator:
Unc
-
Inclosure Type:
Hermetically sealed
-
Operating Voltage Rating And Type Per Function:
20.0 volts dc 4th radio interference 4th function
-
Operating Voltage Rating And Type Per Function:
20.0 volts dc 5th radio interference 5th function
-
Operating Voltage Rating And Type Per Function:
20.0 volts dc 6th radio interference 6th function
-
Operating Voltage Rating And Type Per Function:
29.0 volts dc 1st radio interference 1st function
-
Operating Voltage Rating And Type Per Function:
29.0 volts dc 2nd radio interference 2nd function
-
Operating Voltage Rating And Type Per Function:
29.0 volts dc 3rd radio interference 3rd function
-
Thread Size:
0.086 inches
-
Body Material:
Metal
-
Maximum Dielectric Withstanding Dc Voltage:
250.0 volts at sea level
-
Federal Supply Class (fsc):
Filters and networks
-
National Stock Number (nsn):
5915-00-267-9070