6.000 inches nominal overall length.
Rectangular terminal/terminals on opposite surfaces.
Includes quality control certificate of conformance.
-
Overall Height:
1.739 inches
-
Body Length:
5.660 inches
-
Body Height:
1.250 inches
-
Unthreaded Mounting Hole Diameter:
0.219 inches
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
4.130 inches
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
4.380 inches
-
Source Impedance Rating Per Function:
50.0 ohms 1st radio interference
-
Source Impedance Rating Per Function:
50.0 ohms 2nd radio interference
-
Source Impedance Rating Per Function:
50.0 ohms 3rd radio interference
-
Load Impedance Per Function:
50.0 ohms 1st radio interference
-
Load Impedance Per Function:
50.0 ohms 3rd radio interference
-
Load Impedance Per Function:
50.0 ohms 2nd radio interference
-
Power Line Frequency Rating Per Function In Hertz:
420.0 1st radio interference
-
Power Line Frequency Rating Per Function In Hertz:
420.0 2nd radio interference
-
Power Line Frequency Rating Per Function In Hertz:
420.0 3rd radio interference
-
Operating Current Rating Per Function In Amps:
3.0 1st radio interference
-
Operating Current Rating Per Function In Amps:
3.0 3rd radio interference
-
Operating Current Rating Per Function In Amps:
3.0 2nd radio interference
-
Maximum Voltage Drop Per Function:
1.15 volts ac 1st radio interference and 4.0 volts dc 1st radio interference
-
Maximum Voltage Drop Per Function:
1.15 volts ac 2nd radio interference and 4.0 volts dc 2nd radio interference
-
Maximum Voltage Drop Per Function:
1.15 volts ac 3rd radio interference and 4.0 volts dc 3rd radio interference
-
Inclosure Type:
Hermetically sealed
-
Mounting Facility Type And Quantity:
4 unthreaded hole
-
Functional Terminal Type And Quantity:
3 wire lead output and 1 connector, receptacle input
-
Operating Voltage Rating And Type Per Function:
115.0 volts ac 1st radio interference 1st function and 400.0 volts dc 1st radio interference 1st function
-
Operating Voltage Rating And Type Per Function:
115.0 volts ac 2nd radio interference 2nd function and 400.0 volts dc 2nd radio interference 2nd function
-
Operating Voltage Rating And Type Per Function:
115.0 volts ac 3rd radio interference 3rd function and 400.0 volts dc 3rd radio interference 3rd function
-
Style Designator:
Rectangular terminal/terminals on opposite surfaces
-
Federal Supply Class (fsc):
Filters and networks
-
National Stock Number (nsn):
5915-01-103-2636