Radio Frequency Interference Filter

Part Number 337-460-9001

Quality inspected with certificate of conformity. For questions and pricing call us at +1 210-468-8090

We ship worldwide

Features

Rectangular terminal/terminals on one surface.

Includes quality control certificate of conformance.

Specifications

  • Overall Height:
    Between 2.130 inches and 2.250 inches
  • Body Length:
    Between 2.440 inches and 2.560 inches
  • Body Width:
    Between 0.720 inches and 0.780 inches
  • Body Height:
    Between 1.940 inches and 2.060 inches
  • Unthreaded Mounting Hole Diameter:
    Between 0.177 inches and 0.197 inches
  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
    Between 2.045 inches and 2.075 inches
  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
    Between 1.165 inches and 1.195 inches
  • Operating Tempurature Range:
    -65.0/+85.0 degrees fahrenheit
  • Operating Tempurature Range:
    -65.0 to 85.0 degrees fahrenheit
  • Average Life Rating In Hours:
    250.0
  • Source Impedance Rating Per Function:
    50.0 ohms 1st radio interference
  • Source Impedance Rating Per Function:
    50.0 ohms 2nd radio interference
  • Source Impedance Rating Per Function:
    50.0 ohms 3rd radio interference
  • Source Impedance Rating Per Function:
    50.0 ohms 4th radio interference
  • Source Impedance Rating Per Function:
    50.0 ohms 1st radio interference 1st function
  • Source Impedance Rating Per Function:
    50.0 ohms 4th radio interference 4th function
  • Source Impedance Rating Per Function:
    50.0 ohms 2nd radio interference 2nd function
  • Source Impedance Rating Per Function:
    50.0 ohms 3rd radio interference 3rd function
  • Load Impedance Per Function:
    50.0 ohms 1st radio interference
  • Load Impedance Per Function:
    50.0 ohms 3rd radio interference
  • Load Impedance Per Function:
    50.0 ohms 2nd radio interference
  • Load Impedance Per Function:
    50.0 ohms 4th radio interference
  • Load Impedance Per Function:
    50.0 ohms 1st radio interference 1st function
  • Load Impedance Per Function:
    50.0 ohms 2nd radio interference 2nd function
  • Load Impedance Per Function:
    50.0 ohms 3rd radio interference 3rd function
  • Load Impedance Per Function:
    50.0 ohms 4th radio interference 4th function
  • Operating Current Rating Per Function In Amps:
    0.5 1st radio interference
  • Operating Current Rating Per Function In Amps:
    0.5 2nd radio interference
  • Operating Current Rating Per Function In Amps:
    0.5 3rd radio interference
  • Operating Current Rating Per Function In Amps:
    0.5 4th radio interference
  • Operating Current Rating Per Function In Amps:
    0.5 1st radio interference 1st function
  • Operating Current Rating Per Function In Amps:
    0.5 2nd radio interference 2nd function
  • Operating Current Rating Per Function In Amps:
    0.5 3rd radio interference 3rd function
  • Operating Current Rating Per Function In Amps:
    0.5 4th radio interference 4th function
  • Maximum Voltage Drop Per Function:
    150.0 millivolts dc 1st radio interference
  • Maximum Voltage Drop Per Function:
    150.0 millivolts dc 2nd radio interference
  • Maximum Voltage Drop Per Function:
    150.0 millivolts dc 3rd radio interference
  • Maximum Voltage Drop Per Function:
    150.0 millivolts dc 4th radio interference
  • Maximum Voltage Drop Per Function:
    150.0 millivolts dc 1st radio interference 1st function
  • Maximum Voltage Drop Per Function:
    150.0 millivolts dc 2nd radio interference 2nd function
  • Maximum Voltage Drop Per Function:
    150.0 millivolts dc 3rd radio interference 3rd function
  • Maximum Voltage Drop Per Function:
    150.0 millivolts dc 4th radio interference 4th function
  • Principal Circuitry Type Per Function:
    Inductance-capacitance 1st radio interference
  • Principal Circuitry Type Per Function:
    Inductance-capacitance 2nd radio interference
  • Principal Circuitry Type Per Function:
    Inductance-capacitance 4th radio interference
  • Principal Circuitry Type Per Function:
    Inductance-capacitance 3rd radio interference
  • Principal Circuitry Type Per Function:
    Inductance-capacitance 1st radio interference 1st function
  • Principal Circuitry Type Per Function:
    Inductance-capacitance 4th radio interference 4th function
  • Principal Circuitry Type Per Function:
    Inductance-capacitance 2nd radio interference 2nd function
  • Principal Circuitry Type Per Function:
    Inductance-capacitance 3rd radio interference 3rd function
  • Inclosure Type:
    Encased
  • Mounting Facility Type And Quantity:
    4 unthreaded hole
  • Functional Terminal Type And Quantity:
    1 connector, receptacle input-output/ground
  • Operating Voltage Rating And Type Per Function:
    28.0 volts dc 2nd radio interference 2nd function
  • Operating Voltage Rating And Type Per Function:
    28.0 volts dc 3rd radio interference 3rd function
  • Operating Voltage Rating And Type Per Function:
    28.0 volts dc 4th radio interference 4th function
  • Operating Voltage Rating And Type Per Function:
    28.0 volts dc 1st radio interference 1st function
  • Maximum Dielectric Withstanding Dc Voltage:
    200.0 volts at sea level
  • Style Designator:
    Rectangular terminal/terminals on one surface
  • Federal Supply Class (fsc):
    Filters and networks
  • National Stock Number (nsn):
    5915-00-085-0186
  • Special Features:
    1.470 in. Min, 1.530 in. Max o/a width

Price Quote and Buy

Receive a quote by email then order online or over the phone.
5915000850186
Privacy    Terms

Quality Distribution Professional and certified distributor

  • ISO 9001:2015 + AS9120B
  • ITAR Registered
  • Quality inspected NSNs
  • Counterfeit Parts Prevention