Body Length:
Between 2.070 inches and 2.130 inches
-
Body Width:
Between 2.070 inches and 2.130 inches
-
Body Height:
Between 1.470 inches and 1.530 inches
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
Between 1.790 inches and 1.810 inches
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
Between 1.790 inches and 1.810 inches
-
Operating Tempurature Range:
-55.0/+65.0 degrees celsius
-
Source Impedance Rating Per Function:
50.0 ohms 1st radio interference
-
Source Impedance Rating Per Function:
50.0 ohms 2nd radio interference
-
Source Impedance Rating Per Function:
50.0 ohms 5th radio interference
-
Source Impedance Rating Per Function:
50.0 ohms 6th radio interference
-
Source Impedance Rating Per Function:
50.0 ohms 3rd radio interference
-
Source Impedance Rating Per Function:
50.0 ohms 4th radio interference
-
Load Impedance Per Function:
50.0 ohms 1st radio interference
-
Load Impedance Per Function:
50.0 ohms 3rd radio interference
-
Load Impedance Per Function:
50.0 ohms 2nd radio interference
-
Load Impedance Per Function:
50.0 ohms 6th radio interference
-
Load Impedance Per Function:
50.0 ohms 4th radio interference
-
Load Impedance Per Function:
50.0 ohms 5th radio interference
-
Operating Current Rating Per Function In Amps:
10.0 1st radio interference
-
Operating Current Rating Per Function In Amps:
10.0 2nd radio interference
-
Operating Current Rating Per Function In Amps:
10.0 3rd radio interference
-
Operating Current Rating Per Function In Amps:
10.0 4th radio interference
-
Operating Current Rating Per Function In Amps:
10.0 5th radio interference
-
Operating Current Rating Per Function In Amps:
10.0 6th radio interference
-
Maximum Voltage Drop Per Function:
0.1 volts dc 2nd radio interference
-
Maximum Voltage Drop Per Function:
0.1 volts dc 3rd radio interference
-
Maximum Voltage Drop Per Function:
0.1 volts dc 4th radio interference
-
Maximum Voltage Drop Per Function:
0.1 volts dc 5th radio interference
-
Maximum Voltage Drop Per Function:
0.1 volts dc 6th radio interference
-
Maximum Voltage Drop Per Function:
0.1 volts dc 1st radio interference
-
Principal Circuitry Type Per Function:
Inductance-capacitance 1st radio interference
-
Principal Circuitry Type Per Function:
Inductance-capacitance 2nd radio interference
-
Principal Circuitry Type Per Function:
Inductance-capacitance 4th radio interference
-
Principal Circuitry Type Per Function:
Inductance-capacitance 3rd radio interference
-
Principal Circuitry Type Per Function:
Inductance-capacitance 5th radio interference
-
Principal Circuitry Type Per Function:
Inductance-capacitance 6th radio interference
-
Maximum Tempurature Rise:
20.0 degrees celsius
-
Mounting Facility Screw Thread Series Designator:
Unc
-
Inclosure Type:
Hermetically sealed
-
Mounting Facility Type And Quantity:
4 threaded hole
-
Functional Terminal Type And Quantity:
1 connector, receptacle input 1st function
-
Functional Terminal Type And Quantity:
12 tab, solder lug output 2nd function
-
Operating Voltage Rating And Type Per Function:
50.0 volts dc 1st radio interference 1st function
-
Operating Voltage Rating And Type Per Function:
50.0 volts dc 2nd radio interference 2nd function
-
Operating Voltage Rating And Type Per Function:
50.0 volts dc 3rd radio interference 3rd function
-
Operating Voltage Rating And Type Per Function:
50.0 volts dc 4th radio interference 4th function
-
Operating Voltage Rating And Type Per Function:
50.0 volts dc 5th radio interference 5th function
-
Operating Voltage Rating And Type Per Function:
50.0 volts dc 6th radio interference 6th function
-
Thread Size:
0.112 inches
-
Body Surface Treatment:
Tin
-
Unpackaged Unit Weight:
2.000 pounds
-
Style Designator:
Rectangular terminal/terminals on opposite surfaces
-
Federal Supply Class (fsc):
Filters and networks
-
National Stock Number (nsn):
5915-01-239-1790
-
Special Features:
12 functions