Radio Frequency Interference Filter

Part Number 39010-5

Quality inspected with certificate of conformity. For questions and pricing call us at +1 210-468-8090

We ship worldwide

Features

53.215 inches minimum and 55.225 inches maximum overall length.

Rectangular terminal/terminals on opposite surfaces.

Includes quality control certificate of conformance.

Specifications

  • Body Length:
    Between 3.460 inches and 3.470 inches
  • Body Width:
    Between 2.930 inches and 2.970 inches
  • Body Height:
    Between 3.170 inches and 3.180 inches
  • Unthreaded Mounting Hole Diameter:
    Between 0.200 inches and 0.220 inches
  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
    Between 3.860 inches and 3.880 inches
  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
    Between 2.730 inches and 2.750 inches
  • Operating Tempurature Range:
    -65.0/+165.0 degrees fahrenheit
  • Operating Tempurature Range:
    -65.0 to 165.0 degrees fahrenheit
  • Source Impedance Rating Per Function:
    50.0 ohms 1st radio interference
  • Source Impedance Rating Per Function:
    50.0 ohms 2nd radio interference
  • Source Impedance Rating Per Function:
    50.0 ohms 5th radio interference
  • Source Impedance Rating Per Function:
    50.0 ohms 6th radio interference
  • Source Impedance Rating Per Function:
    50.0 ohms 3rd radio interference
  • Source Impedance Rating Per Function:
    50.0 ohms 4th radio interference
  • Source Impedance Rating Per Function:
    50.0 ohms 1st radio interference 1st function
  • Source Impedance Rating Per Function:
    50.0 ohms 4th radio interference 4th function
  • Source Impedance Rating Per Function:
    50.0 ohms 6th radio interference 6th function
  • Load Impedance Per Function:
    50.0 ohms 1st radio interference
  • Load Impedance Per Function:
    50.0 ohms 3rd radio interference
  • Load Impedance Per Function:
    50.0 ohms 2nd radio interference
  • Load Impedance Per Function:
    50.0 ohms 6th radio interference
  • Load Impedance Per Function:
    50.0 ohms 4th radio interference
  • Load Impedance Per Function:
    50.0 ohms 5th radio interference
  • Load Impedance Per Function:
    50.0 ohms 2nd radio interference 2nd function
  • Load Impedance Per Function:
    50.0 ohms 6th radio interference 6th function
  • Load Impedance Per Function:
    50.0 ohms 4th radio interference 4th function
  • Power Line Frequency Rating Per Function In Hertz:
    400.0 1st radio interference
  • Power Line Frequency Rating Per Function In Hertz:
    400.0 2nd radio interference
  • Power Line Frequency Rating Per Function In Hertz:
    400.0 3rd radio interference
  • Power Line Frequency Rating Per Function In Hertz:
    400.0 4th radio interference
  • Power Line Frequency Rating Per Function In Hertz:
    400.0 5th radio interference
  • Power Line Frequency Rating Per Function In Hertz:
    400.0 5th radio interference 5th function
  • Power Line Frequency Rating Per Function In Hertz:
    400.0 2nd radio interference 2nd function
  • Operating Current Rating Per Function In Amps:
    1.0 1st radio interference
  • Operating Current Rating Per Function In Amps:
    1.0 3rd radio interference
  • Operating Current Rating Per Function In Amps:
    1.0 4th radio interference
  • Operating Current Rating Per Function In Amps:
    1.0 2nd radio interference
  • Operating Current Rating Per Function In Amps:
    1.0 5th radio interference
  • Operating Current Rating Per Function In Amps:
    1.0 6th radio interference
  • Operating Current Rating Per Function In Amps:
    1.0 2nd radio interference 2nd function
  • Operating Current Rating Per Function In Amps:
    1.0 4th radio interference 4th function
  • Maximum Voltage Drop Per Function:
    1.0 volts ac 2nd radio interference
  • Maximum Voltage Drop Per Function:
    1.0 volts ac 1st radio interference
  • Maximum Voltage Drop Per Function:
    1.0 volts ac 3rd radio interference
  • Maximum Voltage Drop Per Function:
    1.0 volts ac 4th radio interference
  • Maximum Voltage Drop Per Function:
    1.0 volts ac 5th radio interference
  • Maximum Voltage Drop Per Function:
    350.0 millivolts dc 6th radio interference
  • Maximum Voltage Drop Per Function:
    1.0 volts ac 3rd radio interference 3rd function
  • Maximum Voltage Drop Per Function:
    1.0 volts ac 5th radio interference 5th function
  • Maximum Voltage Drop Per Function:
    1.0 volts ac 1st radio interference 1st function
  • Principal Circuitry Type Per Function:
    Inductance-capacitance 1st radio interference
  • Principal Circuitry Type Per Function:
    Inductance-capacitance 2nd radio interference
  • Principal Circuitry Type Per Function:
    Inductance-capacitance 4th radio interference
  • Principal Circuitry Type Per Function:
    Inductance-capacitance 3rd radio interference
  • Principal Circuitry Type Per Function:
    Inductance-capacitance 5th radio interference
  • Principal Circuitry Type Per Function:
    Inductance-capacitance 6th radio interference
  • Principal Circuitry Type Per Function:
    Inductance-capacitance 1st radio interference 1st function
  • Principal Circuitry Type Per Function:
    Inductance-capacitance 4th radio interference 4th function
  • Principal Circuitry Type Per Function:
    Inductance-capacitance 6th radio interference 6th function
  • Input Terminal Identification:
    Ms3106e20-7p
  • Output Terminal Manufacturer Code:
    96906
  • Output Terminal Identification:
    Ms3106e20-7p
  • Inclosure Type:
    Hermetically sealed
  • Mounting Facility Type And Quantity:
    4 unthreaded hole
  • Functional Terminal Type And Quantity:
    1 connector, plug input 1st function
  • Functional Terminal Type And Quantity:
    1 connector, plug output 2nd function
  • Maximum Dielectric Withstanding Ac Rms Voltage:
    230.0 volts at sea level
  • Operating Voltage Rating And Type Per Function:
    28.0 volts dc 6th radio interference 6th function
  • Operating Voltage Rating And Type Per Function:
    115.0 volts ac 1st radio interference 1st function
  • Operating Voltage Rating And Type Per Function:
    115.0 volts ac 2nd radio interference 2nd function
  • Operating Voltage Rating And Type Per Function:
    115.0 volts ac 3rd radio interference 3rd function
  • Operating Voltage Rating And Type Per Function:
    115.0 volts ac 4th radio interference 4th function
  • Operating Voltage Rating And Type Per Function:
    115.0 volts ac 5th radio interference 5th function
  • Body Material:
    Metal
  • Maximum Dielectric Withstanding Dc Voltage:
    56.0 volts at sea level
  • Unpackaged Unit Weight:
    3.000 pounds
  • Style Designator:
    Rectangular terminal/terminals on opposite surfaces
  • Federal Supply Class (fsc):
    Filters and networks
  • National Stock Number (nsn):
    5915-00-119-7331
  • Special Features:
    Six filtered functions

Price Quote and Buy

Receive a quote by email then order online or over the phone.
5915001197331
Privacy    Terms

Quality Distribution Professional and certified distributor

  • ISO 9001:2015 + AS9120B
  • ITAR Registered
  • Quality inspected NSNs
  • Counterfeit Parts Prevention