Body Length:
Between 3.460 inches and 3.470 inches
-
Body Width:
Between 2.930 inches and 2.970 inches
-
Body Height:
Between 3.170 inches and 3.180 inches
-
Unthreaded Mounting Hole Diameter:
Between 0.200 inches and 0.220 inches
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
Between 3.860 inches and 3.880 inches
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
Between 2.730 inches and 2.750 inches
-
Operating Tempurature Range:
-65.0/+165.0 degrees fahrenheit
-
Operating Tempurature Range:
-65.0 to 165.0 degrees fahrenheit
-
Source Impedance Rating Per Function:
50.0 ohms 1st radio interference
-
Source Impedance Rating Per Function:
50.0 ohms 2nd radio interference
-
Source Impedance Rating Per Function:
50.0 ohms 5th radio interference
-
Source Impedance Rating Per Function:
50.0 ohms 6th radio interference
-
Source Impedance Rating Per Function:
50.0 ohms 3rd radio interference
-
Source Impedance Rating Per Function:
50.0 ohms 4th radio interference
-
Source Impedance Rating Per Function:
50.0 ohms 1st radio interference 1st function
-
Source Impedance Rating Per Function:
50.0 ohms 4th radio interference 4th function
-
Source Impedance Rating Per Function:
50.0 ohms 6th radio interference 6th function
-
Load Impedance Per Function:
50.0 ohms 1st radio interference
-
Load Impedance Per Function:
50.0 ohms 3rd radio interference
-
Load Impedance Per Function:
50.0 ohms 2nd radio interference
-
Load Impedance Per Function:
50.0 ohms 6th radio interference
-
Load Impedance Per Function:
50.0 ohms 4th radio interference
-
Load Impedance Per Function:
50.0 ohms 5th radio interference
-
Load Impedance Per Function:
50.0 ohms 2nd radio interference 2nd function
-
Load Impedance Per Function:
50.0 ohms 6th radio interference 6th function
-
Load Impedance Per Function:
50.0 ohms 4th radio interference 4th function
-
Power Line Frequency Rating Per Function In Hertz:
400.0 1st radio interference
-
Power Line Frequency Rating Per Function In Hertz:
400.0 2nd radio interference
-
Power Line Frequency Rating Per Function In Hertz:
400.0 3rd radio interference
-
Power Line Frequency Rating Per Function In Hertz:
400.0 4th radio interference
-
Power Line Frequency Rating Per Function In Hertz:
400.0 5th radio interference
-
Power Line Frequency Rating Per Function In Hertz:
400.0 5th radio interference 5th function
-
Power Line Frequency Rating Per Function In Hertz:
400.0 2nd radio interference 2nd function
-
Operating Current Rating Per Function In Amps:
1.0 1st radio interference
-
Operating Current Rating Per Function In Amps:
1.0 3rd radio interference
-
Operating Current Rating Per Function In Amps:
1.0 4th radio interference
-
Operating Current Rating Per Function In Amps:
1.0 2nd radio interference
-
Operating Current Rating Per Function In Amps:
1.0 5th radio interference
-
Operating Current Rating Per Function In Amps:
1.0 6th radio interference
-
Operating Current Rating Per Function In Amps:
1.0 2nd radio interference 2nd function
-
Operating Current Rating Per Function In Amps:
1.0 4th radio interference 4th function
-
Maximum Voltage Drop Per Function:
1.0 volts ac 2nd radio interference
-
Maximum Voltage Drop Per Function:
1.0 volts ac 1st radio interference
-
Maximum Voltage Drop Per Function:
1.0 volts ac 3rd radio interference
-
Maximum Voltage Drop Per Function:
1.0 volts ac 4th radio interference
-
Maximum Voltage Drop Per Function:
1.0 volts ac 5th radio interference
-
Maximum Voltage Drop Per Function:
350.0 millivolts dc 6th radio interference
-
Maximum Voltage Drop Per Function:
1.0 volts ac 3rd radio interference 3rd function
-
Maximum Voltage Drop Per Function:
1.0 volts ac 5th radio interference 5th function
-
Maximum Voltage Drop Per Function:
1.0 volts ac 1st radio interference 1st function
-
Principal Circuitry Type Per Function:
Inductance-capacitance 1st radio interference
-
Principal Circuitry Type Per Function:
Inductance-capacitance 2nd radio interference
-
Principal Circuitry Type Per Function:
Inductance-capacitance 4th radio interference
-
Principal Circuitry Type Per Function:
Inductance-capacitance 3rd radio interference
-
Principal Circuitry Type Per Function:
Inductance-capacitance 5th radio interference
-
Principal Circuitry Type Per Function:
Inductance-capacitance 6th radio interference
-
Principal Circuitry Type Per Function:
Inductance-capacitance 1st radio interference 1st function
-
Principal Circuitry Type Per Function:
Inductance-capacitance 4th radio interference 4th function
-
Principal Circuitry Type Per Function:
Inductance-capacitance 6th radio interference 6th function
-
Input Terminal Identification:
Ms3106e20-7p
-
Output Terminal Manufacturer Code:
96906
-
Output Terminal Identification:
Ms3106e20-7p
-
Inclosure Type:
Hermetically sealed
-
Mounting Facility Type And Quantity:
4 unthreaded hole
-
Functional Terminal Type And Quantity:
1 connector, plug input 1st function
-
Functional Terminal Type And Quantity:
1 connector, plug output 2nd function
-
Maximum Dielectric Withstanding Ac Rms Voltage:
230.0 volts at sea level
-
Operating Voltage Rating And Type Per Function:
28.0 volts dc 6th radio interference 6th function
-
Operating Voltage Rating And Type Per Function:
115.0 volts ac 1st radio interference 1st function
-
Operating Voltage Rating And Type Per Function:
115.0 volts ac 2nd radio interference 2nd function
-
Operating Voltage Rating And Type Per Function:
115.0 volts ac 3rd radio interference 3rd function
-
Operating Voltage Rating And Type Per Function:
115.0 volts ac 4th radio interference 4th function
-
Operating Voltage Rating And Type Per Function:
115.0 volts ac 5th radio interference 5th function
-
Body Material:
Metal
-
Maximum Dielectric Withstanding Dc Voltage:
56.0 volts at sea level
-
Unpackaged Unit Weight:
3.000 pounds
-
Style Designator:
Rectangular terminal/terminals on opposite surfaces
-
Federal Supply Class (fsc):
Filters and networks
-
National Stock Number (nsn):
5915-00-119-7331
-
Special Features:
Six filtered functions