Radio Frequency Interference Filter

Part Number 5004-1009

Quality inspected with certificate of conformity. For questions and pricing call us at +1 210-468-8090

We ship worldwide

Features

6.312 inches nominal overall length.

Fungus resistant rectangular terminal/terminals on opposite surfaces.

Includes quality control certificate of conformance.

Specifications

  • Body Length:
    6.000 inches
  • Body Width:
    1.250 inches
  • Body Height:
    3.000 inches
  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
    4.500 inches
  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
    2.625 inches
  • Operating Tempurature Range:
    -28.0/+65.0 degrees celsius
  • Average Life Rating In Hours:
    1000.0
  • End Application:
    Tactical air operations module an/tyq-2 (v) 1
  • Source Impedance Rating Per Function:
    50.0 ohms 1st radio interference
  • Source Impedance Rating Per Function:
    50.0 ohms 2nd radio interference
  • Load Impedance Per Function:
    50.0 ohms 1st radio interference
  • Load Impedance Per Function:
    50.0 ohms 2nd radio interference
  • Power Line Frequency Rating Per Function In Hertz:
    460.0 1st radio interference
  • Power Line Frequency Rating Per Function In Hertz:
    460.0 2nd radio interference
  • Operating Current Rating Per Function In Amps:
    6.0 1st radio interference
  • Operating Current Rating Per Function In Amps:
    6.0 2nd radio interference
  • Maximum Voltage Drop Per Function:
    3.0 volts ac 1st radio interference
  • Maximum Voltage Drop Per Function:
    3.0 volts ac 2nd radio interference
  • Principal Circuitry Type Per Function:
    Inductance-capacitance 1st radio interference
  • Principal Circuitry Type Per Function:
    Inductance-capacitance 2nd radio interference
  • Input Terminal Manufacturer Code:
    13973
  • Input Terminal Identification:
    Sma-receptacle
  • Maximum Tempurature Rise:
    25.0 degrees celsius
  • Average Power Rating Per Function:
    1.5 watts 1st radio interference
  • Average Power Rating Per Function:
    1.5 watts 2nd radio interference
  • Full Load Insertion Loss Frequencies In Megahertz:
    0.0 and 0.1 and 1.0 and 10.0 and 100.0 and 1000.0
  • Full Load Minimum Insertion Loss At Specificationified Frequency In Decibels:
    20.0 and 75.0 and 90.0 and 90.0 and 90.0 and 90.0
  • Mounting Facility Screw Thread Series Designator:
    Unc
  • Inclosure Type:
    Hermetically sealed
  • Mounting Facility Type And Quantity:
    4 threaded hole
  • Features Provided:
    Fungus resistant and shock resistant
  • Functional Terminal Type And Quantity:
    1 connector, plug input 1st function
  • Functional Terminal Type And Quantity:
    1 tab, solder lug ground 3rd function
  • Functional Terminal Type And Quantity:
    2 tab, solder lug output 2nd function
  • Operating Voltage Rating And Type Per Function:
    150.0 volts ac 2nd radio interference 2nd function
  • Operating Voltage Rating And Type Per Function:
    150.0 volts ac 1st radio interference 1st function
  • Thread Size:
    0.164 inches
  • Body Material:
    Metal
  • Maximum Dielectric Withstanding Dc Voltage:
    300.0 volts at sea level
  • Body Surface Treatment:
    Tin
  • Unpackaged Unit Weight:
    3.500 pounds
  • Style Designator:
    Rectangular terminal/terminals on opposite surfaces
  • Federal Supply Class (fsc):
    Filters and networks
  • National Stock Number (nsn):
    5915-01-336-7668
  • Special Features:
    Two filtered functions

Price Quote and Buy

Receive a quote by email then order online or over the phone.
5915013367668
Privacy    Terms

Quality Distribution Professional and certified distributor

  • ISO 9001:2015 + AS9120B
  • ITAR Registered
  • Quality inspected NSNs