6.500 inches nominal overall length.
13.500" overall width rectangular terminal/terminals on opposite surfaces.
Includes quality control certificate of conformance.
-
Overall Height:
2.190 inches
-
Overall Width:
13.500 inches
-
Body Length:
4.500 inches
-
Body Width:
13.000 inches
-
Unthreaded Mounting Hole Diameter:
0.281 inches
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
5.687 inches
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
9.000 inches
-
End Application:
Generator ac
-
Source Impedance Rating Per Function:
50.0 ohms 1st radio interference 1st function
-
Source Impedance Rating Per Function:
50.0 ohms 2nd radio interference 2nd function
-
Load Impedance Per Function:
50.0 ohms 1st radio interference 1st function
-
Load Impedance Per Function:
50.0 ohms 2nd radio interference 2nd function
-
Power Line Frequency Rating Per Function In Hertz:
60.0 1st radio interference 1st function
-
Power Line Frequency Rating Per Function In Hertz:
60.0 2nd radio interference 2nd function
-
Operating Current Rating Per Function In Amps:
5.0 1st radio interference 1st function
-
Operating Current Rating Per Function In Amps:
5.0 2nd radio interference 2nd function
-
Principal Circuitry Type Per Function:
Inductance-capacitance 1st radio interference 1st function
-
Principal Circuitry Type Per Function:
Inductance-capacitance 2nd radio interference 2nd function
-
Principal Circuitry Type Per Function:
Inductance-capacitance 4th radio interference 4th function
-
Principal Circuitry Type Per Function:
Inductance-capacitance 3rd radio interference 3rd function
-
Inclosure Type:
Encased
-
Mounting Facility Type And Quantity:
6 unthreaded hole all functions
-
Functional Terminal Type And Quantity:
2 threaded stud output 2nd function
-
Functional Terminal Type And Quantity:
2 threaded stud input 1st function
-
Functional Terminal Type And Quantity:
3 threaded stud ground 3rd function
-
Operating Voltage Rating And Type Per Function:
120.0 volts ac 1st radio interference 1st function
-
Operating Voltage Rating And Type Per Function:
120.0 volts ac 2nd radio interference 2nd function
-
Style Designator:
Rectangular terminal/terminals on opposite surfaces
-
Federal Supply Class (fsc):
Filters and networks
-
National Stock Number (nsn):
5915-01-210-1076