Body Length:
Between 5.230 inches and 5.250 inches
-
Body Width:
Between 1.750 inches and 1.770 inches
-
Body Height:
Between 1.750 inches and 1.770 inches
-
Vibration Resistance Range In Hertz:
+10.0/+500.0
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
Between 1.340 inches and 1.360 inches
-
Operating Tempurature Range:
-54.0/+65.0 degrees celsius
-
Average Life Rating In Hours:
1000.0
-
End Application:
Tactical air operations module
-
Source Impedance Rating Per Function:
2.0 kilohms 2nd radio interference
-
Source Impedance Rating Per Function:
2.0 kilohms 3rd radio interference
-
Source Impedance Rating Per Function:
2.0 kilohms 4th radio interference
-
Source Impedance Rating Per Function:
2.0 kilohms 1st radio interference
-
Load Impedance Per Function:
2.0 kilohms 1st radio interference
-
Load Impedance Per Function:
2.0 kilohms 2nd radio interference
-
Load Impedance Per Function:
2.0 kilohms 3rd radio interference
-
Load Impedance Per Function:
2.0 kilohms 4th radio interference
-
Power Line Frequency Rating Per Function In Hertz:
5000.0 3rd radio interference
-
Power Line Frequency Rating Per Function In Hertz:
5000.0 4th radio interference
-
Power Line Frequency Rating Per Function In Hertz:
5000.0 1st radio interference
-
Power Line Frequency Rating Per Function In Hertz:
5000.0 2nd radio interference
-
Operating Current Rating Per Function In Amps:
1.0 1st radio interference
-
Operating Current Rating Per Function In Amps:
1.0 3rd radio interference
-
Operating Current Rating Per Function In Amps:
1.0 4th radio interference
-
Operating Current Rating Per Function In Amps:
1.0 2nd radio interference
-
Maximum Voltage Drop Per Function:
50.0 millivolts ac 1st radio interference
-
Maximum Voltage Drop Per Function:
50.0 millivolts ac 2nd radio interference
-
Maximum Voltage Drop Per Function:
50.0 millivolts ac 3rd radio interference
-
Maximum Voltage Drop Per Function:
50.0 millivolts ac 4th radio interference
-
Principal Circuitry Type Per Function:
Inductance-capacitance 1st radio interference
-
Principal Circuitry Type Per Function:
Inductance-capacitance 2nd radio interference
-
Principal Circuitry Type Per Function:
Inductance-capacitance 4th radio interference
-
Principal Circuitry Type Per Function:
Inductance-capacitance 3rd radio interference
-
Full Load Insertion Loss Frequencies In Megahertz:
0.0 and 0.1 and 1.0 and 10.0 and 100.0 and 1000.0
-
Full Load Minimum Insertion Loss At Specificationified Frequency In Decibels:
1.5 and 3.0 and 78.0 and 78.0 and 100.0 and 100.0
-
Mounting Facility Screw Thread Series Designator:
Unc
-
Inclosure Type:
Hermetically sealed
-
Mounting Facility Type And Quantity:
6 threaded hole
-
Features Provided:
Fungus resistant and shock resistant
-
Functional Terminal Type And Quantity:
2 threaded stud ground 3rd function
-
Functional Terminal Type And Quantity:
4 threaded stud input 1st function
-
Functional Terminal Type And Quantity:
4 threaded stud output 2nd function
-
Operating Voltage Rating And Type Per Function:
5.0 volts ac 3rd radio interference 3rd function
-
Operating Voltage Rating And Type Per Function:
5.0 volts ac 4th radio interference 4th function
-
Operating Voltage Rating And Type Per Function:
5.0 volts ac 1st radio interference 1st function
-
Operating Voltage Rating And Type Per Function:
5.0 volts ac 2nd radio interference 2nd function
-
Thread Size:
0.164 inches
-
Body Material:
Metal
-
Maximum Dielectric Withstanding Dc Voltage:
500.0 volts at sea level
-
Body Surface Treatment:
Tin
-
Unpackaged Unit Weight:
1.800 pounds
-
Style Designator:
Rectangular terminal/terminals on opposite surfaces
-
Federal Supply Class (fsc):
Filters and networks
-
National Stock Number (nsn):
5915-01-331-4073
-
Special Features:
Four filtered functions