Overall Height:
2.875 inches
-
Body Length:
2.250 inches
-
Body Width:
1.360 inches
-
Body Height:
2.000 inches
-
Operating Tempurature Range:
-55.0/+85.0 degrees celsius
-
Source Impedance Rating Per Function:
50.0 ohms 1st radio interference
-
Source Impedance Rating Per Function:
50.0 ohms 2nd radio interference
-
Source Impedance Rating Per Function:
50.0 ohms 5th radio interference
-
Source Impedance Rating Per Function:
50.0 ohms 6th radio interference
-
Source Impedance Rating Per Function:
50.0 ohms 3rd radio interference
-
Source Impedance Rating Per Function:
50.0 ohms 4th radio interference
-
Source Impedance Rating Per Function:
50.0 ohms 1st radio interference 1st function
-
Source Impedance Rating Per Function:
50.0 ohms 3rd radio interference 3rd function
-
Source Impedance Rating Per Function:
50.0 ohms 6th radio interference 6th function
-
Load Impedance Per Function:
50.0 ohms 1st radio interference
-
Load Impedance Per Function:
50.0 ohms 3rd radio interference
-
Load Impedance Per Function:
50.0 ohms 2nd radio interference
-
Load Impedance Per Function:
50.0 ohms 6th radio interference
-
Load Impedance Per Function:
50.0 ohms 4th radio interference
-
Load Impedance Per Function:
50.0 ohms 5th radio interference
-
Load Impedance Per Function:
50.0 ohms 2nd radio interference 2nd function
-
Load Impedance Per Function:
50.0 ohms 6th radio interference 6th function
-
Load Impedance Per Function:
50.0 ohms 4th radio interference 4th function
-
Power Line Frequency Rating Per Function In Hertz:
400.0 1st radio interference
-
Power Line Frequency Rating Per Function In Hertz:
400.0 2nd radio interference
-
Power Line Frequency Rating Per Function In Hertz:
400.0 3rd radio interference
-
Power Line Frequency Rating Per Function In Hertz:
400.0 2nd radio interference 2nd function
-
Operating Current Rating Per Function In Amps:
5.0 1st radio interference
-
Operating Current Rating Per Function In Amps:
5.0 4th radio interference
-
Operating Current Rating Per Function In Amps:
5.0 5th radio interference
-
Operating Current Rating Per Function In Amps:
5.0 6th radio interference
-
Operating Current Rating Per Function In Amps:
5.0 2nd radio interference
-
Operating Current Rating Per Function In Amps:
5.0 3rd radio interference
-
Operating Current Rating Per Function In Amps:
5.0 2nd radio interference 2nd function
-
Operating Current Rating Per Function In Amps:
5.0 6th radio interference 6th function
-
Operating Current Rating Per Function In Amps:
5.0 4th radio interference 4th function
-
Input Terminal Manufacturer Code:
96906
-
Input Terminal Identification:
Ms27508e14b18p
-
Maximum Tempurature Rise:
25.0 degrees celsius
-
Mounting Facility Screw Thread Series Designator:
Unc
-
Inclosure Type:
Encased
-
Mounting Facility Type And Quantity:
4 captive screws
-
Functional Terminal Type And Quantity:
1 connector, receptacle input 1st function
-
Functional Terminal Type And Quantity:
1 tab, solder lug ground 3rd function
-
Functional Terminal Type And Quantity:
11 tab, solder lug output 2nd function
-
Operating Voltage Rating And Type Per Function:
206.0 volts ac 1st radio interference 1st function
-
Operating Voltage Rating And Type Per Function:
206.0 volts ac 2nd radio interference 2nd function
-
Operating Voltage Rating And Type Per Function:
206.0 volts ac 3rd radio interference 3rd function
-
Operating Voltage Rating And Type Per Function:
50.0 volts dc 4th radio interference 4th function
-
Operating Voltage Rating And Type Per Function:
50.0 volts dc 5th radio interference 5th function
-
Operating Voltage Rating And Type Per Function:
50.0 volts dc 6th radio interference 6th function
-
Thread Size:
0.138 inches
-
Body Material:
Metal
-
Maximum Dielectric Withstanding Dc Voltage:
400.0 volts at sea level
-
Style Designator:
Rectangular terminal/terminals on opposite surfaces
-
Federal Supply Class (fsc):
Filters and networks
-
National Stock Number (nsn):
5915-00-179-4623
-
Special Features:
11 functions