1.080 inches maximum overall length, 0.062 inches maximum body outside diameter.
Round terminal/terminals on opposite surface.
Includes quality control certificate of conformance.
-
Body Length:
0.583 inches
-
Unthreaded Mounting Hole Diameter:
Between 0.117 inches and 0.127 inches
-
End Application:
4920nce399566
-
Source Impedance Rating Per Function:
50.0 ohms 1st radio interference
-
Source Impedance Rating Per Function:
50.0 ohms 2nd radio interference
-
Source Impedance Rating Per Function:
50.0 ohms 5th radio interference
-
Source Impedance Rating Per Function:
50.0 ohms 6th radio interference
-
Source Impedance Rating Per Function:
50.0 ohms 3rd radio interference
-
Source Impedance Rating Per Function:
50.0 ohms 4th radio interference
-
Load Impedance Per Function:
50.0 ohms 1st radio interference
-
Load Impedance Per Function:
50.0 ohms 3rd radio interference
-
Load Impedance Per Function:
50.0 ohms 2nd radio interference
-
Load Impedance Per Function:
50.0 ohms 6th radio interference
-
Load Impedance Per Function:
50.0 ohms 4th radio interference
-
Load Impedance Per Function:
50.0 ohms 5th radio interference
-
Operating Current Rating Per Function In Amps:
15.0 1st radio interference
-
Operating Current Rating Per Function In Amps:
15.0 4th radio interference
-
Operating Current Rating Per Function In Amps:
15.0 5th radio interference
-
Operating Current Rating Per Function In Amps:
15.0 6th radio interference
-
Operating Current Rating Per Function In Amps:
15.0 2nd radio interference
-
Operating Current Rating Per Function In Amps:
15.0 3rd radio interference
-
Inclosure Type:
Encased
-
Mounting Facility Type And Quantity:
2 unthreaded hole
-
Functional Terminal Type And Quantity:
1 connector, receptacle input 1st function
-
Functional Terminal Type And Quantity:
25 friction w/grounding strap and pin output 2nd function
-
Operating Voltage Rating And Type Per Function:
100.0 volts dc 1st radio interference 1st function
-
Operating Voltage Rating And Type Per Function:
100.0 volts dc 2nd radio interference 2nd function
-
Operating Voltage Rating And Type Per Function:
100.0 volts dc 3rd radio interference 3rd function
-
Operating Voltage Rating And Type Per Function:
100.0 volts dc 4th radio interference 4th function
-
Operating Voltage Rating And Type Per Function:
100.0 volts dc 5th radio interference 5th function
-
Operating Voltage Rating And Type Per Function:
100.0 volts dc 6th radio interference 6th function
-
Body Material:
Metal
-
Maximum Dielectric Withstanding Dc Voltage:
250.0 volts at sea level
-
Body Surface Treatment:
Gold
-
Precious Material And Location:
Body surfaces gold
-
Precious Material:
Gold
-
Style Designator:
Round terminal/terminals on opposite surface
-
Federal Supply Class (fsc):
Filters and networks
-
National Stock Number (nsn):
5915-01-282-0519