Operating Tempurature Range:
-55.0/+85.0 degrees celsius
-
Source Impedance Rating Per Function:
50.0 ohms 1st radio interference
-
Source Impedance Rating Per Function:
50.0 ohms 2nd radio interference
-
Source Impedance Rating Per Function:
50.0 ohms 3rd radio interference
-
Load Impedance Per Function:
50.0 ohms 1st radio interference
-
Load Impedance Per Function:
50.0 ohms 3rd radio interference
-
Load Impedance Per Function:
50.0 ohms 2nd radio interference
-
Operating Current Rating Per Function In Amps:
2.0 2nd radio interference
-
Operating Current Rating Per Function In Amps:
2.0 1st radio interference
-
Operating Current Rating Per Function In Amps:
2.0 3rd radio interference
-
Principal Circuitry Type Per Function:
Inductance-capacitance 1st radio interference
-
Principal Circuitry Type Per Function:
Inductance-capacitance 2nd radio interference
-
Principal Circuitry Type Per Function:
Inductance-capacitance 3rd radio interference
-
Inclosure Type:
Hermetically sealed
-
Operating Voltage Rating And Type Per Function:
115.0 volts ac 1st radio interference 1st function
-
Operating Voltage Rating And Type Per Function:
115.0 volts ac 2nd radio interference 2nd function
-
Operating Voltage Rating And Type Per Function:
115.0 volts ac 3rd radio interference 3rd function
-
Body Material:
Metal
-
Federal Supply Class (fsc):
Filters and networks
-
National Stock Number (nsn):
5915-01-377-0170