Overall Height:
2.185 inches
-
Body Length:
6.000 inches
-
Body Width:
3.000 inches
-
Body Height:
2.000 inches
-
Vibration Resistance Range In Hertz:
+10.0/+1000.0
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
2.600 inches
-
Operating Tempurature Range:
-55.0/+85.0 degrees celsius
-
Source Impedance Rating Per Function:
50.0 ohms 1st radio interference
-
Source Impedance Rating Per Function:
50.0 ohms 2nd radio interference
-
Source Impedance Rating Per Function:
50.0 ohms 5th radio interference
-
Source Impedance Rating Per Function:
50.0 ohms 6th radio interference
-
Source Impedance Rating Per Function:
50.0 ohms 3rd radio interference
-
Source Impedance Rating Per Function:
50.0 ohms 4th radio interference
-
Load Impedance Per Function:
50.0 ohms 1st radio interference
-
Load Impedance Per Function:
50.0 ohms 3rd radio interference
-
Load Impedance Per Function:
50.0 ohms 2nd radio interference
-
Load Impedance Per Function:
50.0 ohms 6th radio interference
-
Load Impedance Per Function:
50.0 ohms 4th radio interference
-
Load Impedance Per Function:
50.0 ohms 5th radio interference
-
Power Line Frequency Rating Per Function In Hertz:
400.0 1st radio interference
-
Power Line Frequency Rating Per Function In Hertz:
400.0 2nd radio interference
-
Power Line Frequency Rating Per Function In Hertz:
400.0 3rd radio interference
-
Power Line Frequency Rating Per Function In Hertz:
400.0 4th radio interference
-
Operating Current Rating Per Function In Amps:
0.08 5th radio interference
-
Operating Current Rating Per Function In Amps:
0.5 4th radio interference
-
Operating Current Rating Per Function In Amps:
0.76 6th radio interference
-
Operating Current Rating Per Function In Amps:
1.2 1st radio interference
-
Operating Current Rating Per Function In Amps:
1.2 2nd radio interference
-
Operating Current Rating Per Function In Amps:
1.2 3rd radio interference
-
Maximum Voltage Drop Per Function:
0.04 kilovolts dc 6th radio interference
-
Maximum Voltage Drop Per Function:
0.075 kilovolts dc 5th radio interference
-
Maximum Voltage Drop Per Function:
0.4 kilovolts dc 4th radio interference
-
Maximum Voltage Drop Per Function:
2.0 volts ac 1st radio interference
-
Maximum Voltage Drop Per Function:
2.0 volts ac 2nd radio interference
-
Maximum Voltage Drop Per Function:
2.0 volts dc 3rd radio interference
-
Principal Circuitry Type Per Function:
Inductance-capacitance 4th radio interference
-
Principal Circuitry Type Per Function:
Inductance-capacitance 5th radio interference
-
Principal Circuitry Type Per Function:
Inductance-capacitance 6th radio interference
-
Principal Circuitry Type Per Function:
Inductance-capacitance-resistance 2nd radio interference
-
Principal Circuitry Type Per Function:
Inductance-capacitance-resistance 1st radio interference
-
Principal Circuitry Type Per Function:
Inductance-capacitance-resistance 3rd radio interference
-
Input Terminal Manufacturer Code:
96214
-
Input Terminal Identification:
Sma-connector
-
Output Terminal Manufacturer Code:
96214
-
Output Terminal Identification:
Sma-receptacle
-
Maximum Tempurature Rise:
25.0 degrees celsius
-
Full Load Insertion Loss Frequencies In Megahertz:
0.0 and 0.1 and 0.2 and 0.5 and 50.0 and 100.0
-
Full Load Minimum Insertion Loss At Specificationified Frequency In Decibels:
35.0 and 48.0 and 60.0 and 75.0 and 75.0 and 75.0
-
Mounting Facility Screw Thread Series Designator:
Unc
-
Inclosure Type:
Hermetically sealed
-
Mounting Facility Type And Quantity:
6 threaded hole
-
Features Provided:
Moisture resistant and shock resistant
-
Functional Terminal Type And Quantity:
1 connector, plug input 1st function
-
Functional Terminal Type And Quantity:
1 connector, receptacle output 2nd function
-
Maximum Dielectric Withstanding Ac Rms Voltage:
230.0 volts at sea level
-
Operating Voltage Rating And Type Per Function:
15.0 volts dc 5th radio interference 5th function
-
Operating Voltage Rating And Type Per Function:
5.0 volts dc 6th radio interference 6th function
-
Operating Voltage Rating And Type Per Function:
115.0 volts ac 1st radio interference 1st function
-
Operating Voltage Rating And Type Per Function:
115.0 volts ac 2nd radio interference 2nd function
-
Operating Voltage Rating And Type Per Function:
115.0 volts ac 3rd radio interference 3rd function
-
Operating Voltage Rating And Type Per Function:
115.0 volts ac 4th radio interference 4th function
-
Thread Size:
0.138 inches
-
Body Material:
Metal
-
Maximum Dielectric Withstanding Dc Voltage:
30.0 volts at sea level
-
Body Surface Treatment:
Tin
-
Unpackaged Unit Weight:
4.250 pounds
-
Style Designator:
Rectangular terminal/terminals on two surfaces
-
Federal Supply Class (fsc):
Filters and networks
-
National Stock Number (nsn):
5915-01-255-8278
-
Special Features:
Eleven filtered functions; six unfiltered functions