Overall Height:
3.000 inches
-
Body Length:
2.750 inches
-
Body Width:
2.000 inches
-
Body Height:
2.500 inches
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
2.500 inches
-
Vibration Resistance Range In Hertz:
+10.0/+2000.0
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
1.500 inches
-
Operating Tempurature Range:
-54.0/+85.0 degrees celsius
-
Load Impedance Per Function:
50.0 ohms 1st radio interference
-
Load Impedance Per Function:
50.0 ohms 3rd radio interference
-
Load Impedance Per Function:
50.0 ohms 2nd radio interference
-
Load Impedance Per Function:
50.0 ohms 6th radio interference
-
Load Impedance Per Function:
50.0 ohms 4th radio interference
-
Load Impedance Per Function:
50.0 ohms 5th radio interference
-
Input Impedance Per Function W/load:
50.0 ohms 2nd radio interference
-
Input Impedance Per Function W/load:
50.0 ohms 3rd radio interference
-
Input Impedance Per Function W/load:
50.0 ohms 4th radio interference
-
Input Impedance Per Function W/load:
50.0 ohms 5th radio interference
-
Input Impedance Per Function W/load:
50.0 ohms 6th radio interference
-
Input Impedance Per Function W/load:
50.0 ohms 1st radio interference
-
Output Impedance Per Function W/source Across Input:
50.0 ohms 2nd radio interference
-
Output Impedance Per Function W/source Across Input:
50.0 ohms 3rd radio interference
-
Output Impedance Per Function W/source Across Input:
50.0 ohms 1st radio interference
-
Output Impedance Per Function W/source Across Input:
50.0 ohms 4th radio interference
-
Output Impedance Per Function W/source Across Input:
50.0 ohms 5th radio interference
-
Output Impedance Per Function W/source Across Input:
50.0 ohms 6th radio interference
-
Power Line Frequency Rating Per Function In Hertz:
400.0 1st radio interference
-
Power Line Frequency Rating Per Function In Hertz:
400.0 2nd radio interference
-
Power Line Frequency Rating Per Function In Hertz:
400.0 3rd radio interference
-
Power Line Frequency Rating Per Function In Hertz:
400.0 4th radio interference
-
Operating Current Rating Per Function In Amps:
1.0 1st radio interference
-
Operating Current Rating Per Function In Amps:
1.0 3rd radio interference
-
Operating Current Rating Per Function In Amps:
1.0 4th radio interference
-
Operating Current Rating Per Function In Amps:
1.0 2nd radio interference
-
Operating Current Rating Per Function In Amps:
1.0 5th radio interference
-
Operating Current Rating Per Function In Amps:
1.0 6th radio interference
-
Maximum Voltage Drop Per Function:
2.5 volts ac 1st radio interference
-
Maximum Voltage Drop Per Function:
2.5 volts ac 3rd radio interference
-
Maximum Voltage Drop Per Function:
2.5 volts ac 2nd radio interference
-
Maximum Voltage Drop Per Function:
2.5 volts ac 4th radio interference
-
Maximum Voltage Drop Per Function:
500.0 millivolts dc 5th radio interference
-
Maximum Voltage Drop Per Function:
500.0 millivolts dc 6th radio interference
-
Principal Circuitry Type Per Function:
Inductance-capacitance 1st radio interference
-
Principal Circuitry Type Per Function:
Inductance-capacitance 2nd radio interference
-
Principal Circuitry Type Per Function:
Inductance-capacitance 4th radio interference
-
Principal Circuitry Type Per Function:
Inductance-capacitance 3rd radio interference
-
Principal Circuitry Type Per Function:
Inductance-capacitance 5th radio interference
-
Principal Circuitry Type Per Function:
Inductance-capacitance 6th radio interference
-
Mounting Facility Screw Thread Series Designator:
Unc
-
Inclosure Type:
Hermetically sealed
-
Mounting Facility Type And Quantity:
4 threaded hole
-
Functional Terminal Type And Quantity:
2 tab, solder lug ground 3rd function
-
Functional Terminal Type And Quantity:
6 tab, solder lug output 2nd function
-
Functional Terminal Type And Quantity:
6 tab, solder lug input 1st function
-
Maximum Dielectric Withstanding Ac Rms Voltage:
350.0 volts at sea level
-
Operating Voltage Rating And Type Per Function:
28.0 volts dc 5th radio interference 5th function
-
Operating Voltage Rating And Type Per Function:
28.0 volts dc 6th radio interference 6th function
-
Operating Voltage Rating And Type Per Function:
115.0 volts ac 1st radio interference 1st function
-
Operating Voltage Rating And Type Per Function:
115.0 volts ac 2nd radio interference 2nd function
-
Operating Voltage Rating And Type Per Function:
115.0 volts ac 3rd radio interference 3rd function
-
Operating Voltage Rating And Type Per Function:
115.0 volts ac 4th radio interference 4th function
-
Thread Size:
0.112 inches
-
Body Material:
Metal
-
Maximum Dielectric Withstanding Dc Voltage:
100.0 volts at sea level
-
Style Designator:
Rectangular terminal/terminals on one surface
-
Federal Supply Class (fsc):
Filters and networks
-
National Stock Number (nsn):
5915-00-215-0183