Overall Height:
2.876 inches
-
Mounting Slot Width:
0.140 inches
-
Body Length:
3.500 inches
-
Body Width:
1.375 inches
-
Body Height:
2.000 inches
-
Vibration Resistance Range In Hertz:
+10.0/+2000.0
-
Vibration Resistance Range In Hertz:
+10.0 to 2000.0
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
1.000 inches
-
Operating Tempurature Range:
-54.0/+90.0 degrees celsius
-
Operating Tempurature Range:
-54.0 to 90.0 degrees celsius
-
Source Impedance Rating Per Function:
50.0 ohms 1st radio interference
-
Source Impedance Rating Per Function:
50.0 ohms 2nd radio interference
-
Source Impedance Rating Per Function:
50.0 ohms 5th radio interference
-
Source Impedance Rating Per Function:
50.0 ohms 3rd radio interference
-
Source Impedance Rating Per Function:
50.0 ohms 4th radio interference
-
Source Impedance Rating Per Function:
50.0 ohms 2nd radio interference 2nd function
-
Source Impedance Rating Per Function:
50.0 ohms 5th radio interference 5th function
-
Load Impedance Per Function:
50.0 ohms 1st radio interference
-
Load Impedance Per Function:
50.0 ohms 3rd radio interference
-
Load Impedance Per Function:
50.0 ohms 2nd radio interference
-
Load Impedance Per Function:
50.0 ohms 4th radio interference
-
Load Impedance Per Function:
50.0 ohms 5th radio interference
-
Load Impedance Per Function:
50.0 ohms 2nd radio interference 2nd function
-
Load Impedance Per Function:
50.0 ohms 4th radio interference 4th function
-
Power Line Frequency Rating Per Function In Hertz:
420.0 1st radio interference
-
Power Line Frequency Rating Per Function In Hertz:
420.0 2nd radio interference
-
Power Line Frequency Rating Per Function In Hertz:
420.0 3rd radio interference
-
Power Line Frequency Rating Per Function In Hertz:
420.0 4th radio interference
-
Power Line Frequency Rating Per Function In Hertz:
420.0 5th radio interference
-
Power Line Frequency Rating Per Function In Hertz:
420.0 1st radio interference 1st function
-
Power Line Frequency Rating Per Function In Hertz:
420.0 3rd radio interference 3rd function
-
Operating Current Rating Per Function In Amps:
0.05 3rd radio interference
-
Operating Current Rating Per Function In Amps:
0.05 4th radio interference
-
Operating Current Rating Per Function In Amps:
0.05 5th radio interference
-
Operating Current Rating Per Function In Amps:
5.0 1st radio interference
-
Operating Current Rating Per Function In Amps:
5.0 2nd radio interference
-
Operating Current Rating Per Function In Amps:
0.05 3rd radio interference 3rd function
-
Operating Current Rating Per Function In Amps:
0.05 5th radio interference 5th function
-
Operating Current Rating Per Function In Amps:
5.0 1st radio interference 1st function
-
Maximum Voltage Drop Per Function:
1.5 volts ac 3rd radio interference
-
Maximum Voltage Drop Per Function:
1.5 volts ac 4th radio interference
-
Maximum Voltage Drop Per Function:
1.5 volts ac 5th radio interference
-
Maximum Voltage Drop Per Function:
4.0 volts ac 1st radio interference
-
Maximum Voltage Drop Per Function:
4.0 volts ac 2nd radio interference
-
Maximum Voltage Drop Per Function:
1.5 volts ac 5th radio interference 5th function
-
Maximum Voltage Drop Per Function:
4.0 volts ac 2nd radio interference 2nd function
-
Principal Circuitry Type Per Function:
Inductance-capacitance 1st radio interference
-
Principal Circuitry Type Per Function:
Inductance-capacitance 2nd radio interference
-
Principal Circuitry Type Per Function:
Inductance-capacitance 4th radio interference
-
Principal Circuitry Type Per Function:
Inductance-capacitance 3rd radio interference
-
Principal Circuitry Type Per Function:
Inductance-capacitance 5th radio interference
-
Principal Circuitry Type Per Function:
Inductance-capacitance 4th radio interference 4th function
-
Principal Circuitry Type Per Function:
Inductance-capacitance 2nd radio interference 2nd function
-
Input Terminal Manufacturer Code:
96906
-
Input Terminal Identification:
Ms3112e128p
-
Mounting Facility Screw Thread Series Designator:
Unc
-
Inclosure Type:
Encased
-
Mounting Facility Type And Quantity:
2 slot
-
Mounting Facility Type And Quantity:
4 threaded hole
-
Mounting Facility Type And Quantity:
2 slot 1st function
-
Functional Terminal Type And Quantity:
1 connector, receptacle input 1st function
-
Functional Terminal Type And Quantity:
1 turret ground 3rd function
-
Functional Terminal Type And Quantity:
5 turret output 2nd function
-
Operating Voltage Rating And Type Per Function:
132.0 volts ac 2nd radio interference 1st function
-
Operating Voltage Rating And Type Per Function:
132.0 volts ac 2nd radio interference 2nd function
-
Operating Voltage Rating And Type Per Function:
132.0 volts ac 3rd radio interference 3rd function
-
Operating Voltage Rating And Type Per Function:
132.0 volts ac 4th radio interference 4th function
-
Operating Voltage Rating And Type Per Function:
132.0 volts ac 5th radio interference 5th function
-
Thread Size:
0.112 inches
-
Body Surface Treatment:
Tin
-
Style Designator:
Rectangular terminal/terminals on two surfaces
-
Federal Supply Class (fsc):
Filters and networks
-
National Stock Number (nsn):
5915-00-156-0088
-
Special Features:
One ground function