8.620 inches nominal overall length.
Rectangular terminal/terminals on opposite surfaces.
Includes quality control certificate of conformance.
-
Overall Height:
4.000 inches
-
Mounting Slot Width:
0.180 inches
-
Body Length:
7.000 inches
-
Body Width:
4.000 inches
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
3.250 inches
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
7.810 inches
-
End Application:
Star window airborne system and rct
-
Source Impedance Rating Per Function:
50.0 cnb ohms per 1000 feet
-
Source Impedance Rating Per Function:
50.0 cnb ohms per foot
-
Source Impedance Rating Per Function:
50.0 cnb ohms per mile
-
Load Impedance Per Function:
50.0 ohms 1st radio interference
-
Load Impedance Per Function:
50.0 ohms 3rd radio interference
-
Load Impedance Per Function:
50.0 ohms 2nd radio interference
-
Power Line Frequency Rating Per Function In Hertz:
400.0 1st radio interference
-
Power Line Frequency Rating Per Function In Hertz:
400.0 2nd radio interference
-
Power Line Frequency Rating Per Function In Hertz:
400.0 3rd radio interference
-
Operating Current Rating Per Function In Amps:
5.0 1st radio interference
-
Operating Current Rating Per Function In Amps:
5.0 2nd radio interference
-
Operating Current Rating Per Function In Amps:
5.0 3rd radio interference
-
Full Load Insertion Loss Frequencies In Megahertz:
0.02 and 0.05 and 0.15 and 1.5 and 5.0 and 50.0
-
Full Load Minimum Insertion Loss At Specificationified Frequency In Decibels:
24.0 and 34.0 and 65.0 and 65.0 and 65.0 and 60.0
-
Inclosure Type:
Encased
-
Mounting Facility Type And Quantity:
4 slot
-
Functional Terminal Type And Quantity:
1 threaded stud ground 3rd function
-
Functional Terminal Type And Quantity:
3 threaded stud output 2nd function
-
Functional Terminal Type And Quantity:
3 threaded stud input 1st function
-
Operating Voltage Rating And Type Per Function:
125.0 volts ac 3rd radio interference 3rd function and 250.0 volts ac 3rd radio interference 3rd function
-
Operating Voltage Rating And Type Per Function:
125.0 volts ac 2nd radio interference 2nd function and 250.0 volts ac 2nd radio interference 2nd function
-
Operating Voltage Rating And Type Per Function:
125.0 volts ac 1st radio interference 1st function and 250.0 volts ac 1st radio interference 1st function
-
Style Designator:
Rectangular terminal/terminals on opposite surfaces
-
Federal Supply Class (fsc):
Filters and networks
-
National Stock Number (nsn):
5915-01-466-0893
-
Special Features:
Low pass emi filter for eliminating power line interference; 3 phase