Overall Height:
2.840 inches
-
Body Length:
1.937 inches
-
Body Width:
1.468 inches
-
Body Height:
2.000 inches
-
Operating Tempurature Range:
-55.0/+71.0 degrees celsius
-
Operating Tempurature Range:
-55.0 to 71.0 degrees celsius
-
Source Impedance Rating Per Function:
50.0 ohms 1st radio interference
-
Source Impedance Rating Per Function:
50.0 ohms 2nd radio interference
-
Source Impedance Rating Per Function:
50.0 ohms 3rd radio interference
-
Source Impedance Rating Per Function:
50.0 ohms 1st radio interference 1st function
-
Source Impedance Rating Per Function:
50.0 ohms 2nd radio interference 2nd function
-
Source Impedance Rating Per Function:
50.0 ohms 3rd radio interference 3rd function
-
Load Impedance Per Function:
50.0 ohms 1st radio interference
-
Load Impedance Per Function:
50.0 ohms 3rd radio interference
-
Load Impedance Per Function:
50.0 ohms 2nd radio interference
-
Load Impedance Per Function:
50.0 ohms 1st radio interference 1st function
-
Load Impedance Per Function:
50.0 ohms 2nd radio interference 2nd function
-
Load Impedance Per Function:
50.0 ohms 3rd radio interference 3rd function
-
Power Line Frequency Rating Per Function In Hertz:
400.0 1st radio interference
-
Power Line Frequency Rating Per Function In Hertz:
400.0 2nd radio interference
-
Power Line Frequency Rating Per Function In Hertz:
400.0 3rd radio interference
-
Power Line Frequency Rating Per Function In Hertz:
400.0 1st radio interference 1st function
-
Power Line Frequency Rating Per Function In Hertz:
400.0 2nd radio interference 2nd function
-
Power Line Frequency Rating Per Function In Hertz:
400.0 3rd radio interference 3rd function
-
Operating Current Rating Per Function In Amps:
10.0 1st radio interference
-
Operating Current Rating Per Function In Amps:
10.0 2nd radio interference
-
Operating Current Rating Per Function In Amps:
10.0 3rd radio interference
-
Operating Current Rating Per Function In Amps:
10.0 1st radio interference 1st function
-
Operating Current Rating Per Function In Amps:
10.0 2nd radio interference 2nd function
-
Operating Current Rating Per Function In Amps:
10.0 3rd radio interference 3rd function
-
Maximum Voltage Drop Per Function:
0.2 volts ac 1st radio interference
-
Maximum Voltage Drop Per Function:
0.2 volts ac 2nd radio interference
-
Maximum Voltage Drop Per Function:
0.2 volts ac 3rd radio interference
-
Maximum Voltage Drop Per Function:
0.2 volts ac 1st radio interference 1st function
-
Maximum Voltage Drop Per Function:
0.2 volts ac 2nd radio interference 2nd function
-
Maximum Voltage Drop Per Function:
0.2 volts ac 3rd radio interference 3rd function
-
Maximum Tempurature Rise:
25.0 degrees celsius
-
Mounting Facility Screw Thread Series Designator:
Unc
-
Inclosure Type:
Hermetically sealed
-
Mounting Facility Type And Quantity:
1 threaded stud
-
Functional Terminal Type And Quantity:
2 turret ground 3rd function
-
Functional Terminal Type And Quantity:
3 turret input 1st function
-
Functional Terminal Type And Quantity:
3 turret output 2nd function
-
Maximum Dielectric Withstanding Ac Rms Voltage:
230.0 volts at sea level
-
Operating Voltage Rating And Type Per Function:
115.0 volts ac 1st radio interference 1st function
-
Operating Voltage Rating And Type Per Function:
115.0 volts ac 2nd radio interference 2nd function
-
Operating Voltage Rating And Type Per Function:
115.0 volts ac 3rd radio interference 3rd function
-
Thread Size:
0.138 inches
-
Body Material:
Metal
-
Body Surface Treatment:
Tin
-
Unpackaged Unit Weight:
8.000 ounces
-
Style Designator:
Rectangular terminal/terminals on one surface
-
Federal Supply Class (fsc):
Filters and networks
-
National Stock Number (nsn):
5915-00-116-8306