Radio Frequency Interference Filter

Part Number FA4292A

Quality inspected with certificate of conformity. For questions and pricing call us at +1 210-468-8090

We ship worldwide

Features

2.876 inches nominal overall length.

2.620" overall width rectangular terminal/terminals on opposite surfaces.

Includes quality control certificate of conformance.

Specifications

  • Overall Height:
    16.250 inches
  • Overall Width:
    2.620 inches
  • Body Length:
    2.000 inches
  • Body Width:
    4.000 inches
  • Unthreaded Mounting Hole Diameter:
    0.209 inches
  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
    2.500 inches
  • Vibration Resistance Range In Hertz:
    +5.0/+500.0
  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
    1.250 inches
  • Operating Tempurature Range:
    -55.0/+100.0 degrees celsius
  • Source Impedance Rating Per Function:
    50.0 ohms 1st radio interference
  • Source Impedance Rating Per Function:
    50.0 ohms 2nd radio interference
  • Source Impedance Rating Per Function:
    50.0 ohms 5th radio interference
  • Source Impedance Rating Per Function:
    50.0 ohms 3rd radio interference
  • Source Impedance Rating Per Function:
    50.0 ohms 4th radio interference
  • Load Impedance Per Function:
    50.0 ohms 1st radio interference
  • Load Impedance Per Function:
    50.0 ohms 3rd radio interference
  • Load Impedance Per Function:
    50.0 ohms 2nd radio interference
  • Load Impedance Per Function:
    50.0 ohms 4th radio interference
  • Load Impedance Per Function:
    50.0 ohms 5th radio interference
  • Power Line Frequency Rating Per Function In Hertz:
    400.0 1st radio interference
  • Power Line Frequency Rating Per Function In Hertz:
    400.0 2nd radio interference
  • Power Line Frequency Rating Per Function In Hertz:
    400.0 3rd radio interference
  • Operating Current Rating Per Function In Amps:
    0.05 4th radio interference
  • Operating Current Rating Per Function In Amps:
    0.1 5th radio interference
  • Operating Current Rating Per Function In Amps:
    2.0 2nd radio interference
  • Operating Current Rating Per Function In Amps:
    2.0 1st radio interference
  • Operating Current Rating Per Function In Amps:
    2.0 3rd radio interference
  • Maximum Voltage Drop Per Function:
    1.5 volts ac 1st radio interference
  • Maximum Voltage Drop Per Function:
    1.5 volts ac 2nd radio interference
  • Maximum Voltage Drop Per Function:
    1.5 volts ac 3rd radio interference
  • Maximum Voltage Drop Per Function:
    500.0 millivolts dc 4th radio interference
  • Maximum Voltage Drop Per Function:
    500.0 millivolts dc 5th radio interference
  • Principal Circuitry Type Per Function:
    Inductance-capacitance 1st radio interference
  • Principal Circuitry Type Per Function:
    Inductance-capacitance 2nd radio interference
  • Principal Circuitry Type Per Function:
    Inductance-capacitance 4th radio interference
  • Principal Circuitry Type Per Function:
    Inductance-capacitance 3rd radio interference
  • Principal Circuitry Type Per Function:
    Inductance-capacitance 5th radio interference
  • Inclosure Type:
    Hermetically sealed
  • Mounting Facility Type And Quantity:
    4 unthreaded hole
  • Functional Terminal Type And Quantity:
    5 wire hook output 2nd function
  • Functional Terminal Type And Quantity:
    5 wire lead input 1st function
  • Maximum Dielectric Withstanding Ac Rms Voltage:
    600.0 volts at sea level
  • Operating Voltage Rating And Type Per Function:
    300.0 volts dc 4th radio interference 4th function
  • Operating Voltage Rating And Type Per Function:
    100.0 volts dc 5th radio interference 5th function
  • Operating Voltage Rating And Type Per Function:
    115.0 volts ac 1st radio interference 1st function
  • Operating Voltage Rating And Type Per Function:
    115.0 volts ac 2nd radio interference 2nd function
  • Operating Voltage Rating And Type Per Function:
    115.0 volts ac 3rd radio interference 3rd function
  • Style Designator:
    Rectangular terminal/terminals on opposite surfaces
  • Federal Supply Class (fsc):
    Filters and networks
  • National Stock Number (nsn):
    5915-00-952-0591

Price Quote and Buy

Receive a quote by email then order online or over the phone.
5915009520591
Privacy    Terms

Quality Distribution Professional and certified distributor

  • ISO 9001:2015 + AS9120B
  • ITAR Registered
  • Quality inspected NSNs