Operating Tempurature Range:
-55.0/+100.0 degrees celsius
-
Average Life Rating In Hours:
5000.0
-
Power Line Frequency Rating Per Function In Hertz:
400.0 1st radio interference
-
Power Line Frequency Rating Per Function In Hertz:
400.0 2nd radio interference
-
Power Line Frequency Rating Per Function In Hertz:
400.0 3rd radio interference
-
Operating Current Rating Per Function In Amps:
1.9 2nd radio interference
-
Operating Current Rating Per Function In Amps:
1.9 3rd radio interference
-
Operating Current Rating Per Function In Amps:
1.9 1st radio interference
-
Principal Circuitry Type Per Function:
Inductance-capacitance 1st radio interference
-
Principal Circuitry Type Per Function:
Inductance-capacitance 2nd radio interference
-
Principal Circuitry Type Per Function:
Inductance-capacitance 3rd radio interference
-
Input Terminal Manufacturer Code:
96906
-
Input Terminal Identification:
Ms3124e10-6p
-
Inclosure Type:
Encased
-
Functional Terminal Type And Quantity:
1 connector, receptacle input 1st function
-
Functional Terminal Type And Quantity:
3 threaded stud output 2nd function
-
Operating Voltage Rating And Type Per Function:
120.0 volts ac 1st radio interference 1st function
-
Operating Voltage Rating And Type Per Function:
120.0 volts ac 3rd radio interference 3rd function
-
Operating Voltage Rating And Type Per Function:
120.0 volts ac 2nd radio interference 2nd function
-
Federal Supply Class (fsc):
Filters and networks
-
National Stock Number (nsn):
5915-00-215-0192