Overall Height:
5.681 inches
-
Body Length:
2.750 inches
-
Body Width:
1.812 inches
-
Body Height:
5.125 inches
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
2.250 inches
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
1.312 inches
-
Operating Tempurature Range:
-40.0/+55.0 degrees celsius
-
Source Impedance Rating Per Function:
50.0 ohms 1st radio interference
-
Source Impedance Rating Per Function:
50.0 ohms 2nd radio interference
-
Source Impedance Rating Per Function:
50.0 ohms 5th radio interference
-
Source Impedance Rating Per Function:
50.0 ohms 6th radio interference
-
Source Impedance Rating Per Function:
50.0 ohms 3rd radio interference
-
Source Impedance Rating Per Function:
50.0 ohms 4th radio interference
-
Load Impedance Per Function:
50.0 ohms 1st radio interference
-
Load Impedance Per Function:
50.0 ohms 3rd radio interference
-
Load Impedance Per Function:
50.0 ohms 2nd radio interference
-
Load Impedance Per Function:
50.0 ohms 6th radio interference
-
Load Impedance Per Function:
50.0 ohms 4th radio interference
-
Load Impedance Per Function:
50.0 ohms 5th radio interference
-
Power Line Frequency Rating Per Function In Hertz:
400.0 1st radio interference
-
Power Line Frequency Rating Per Function In Hertz:
400.0 2nd radio interference
-
Power Line Frequency Rating Per Function In Hertz:
400.0 3rd radio interference
-
Power Line Frequency Rating Per Function In Hertz:
400.0 4th radio interference
-
Power Line Frequency Rating Per Function In Hertz:
400.0 5th radio interference
-
Power Line Frequency Rating Per Function In Hertz:
400.0 6th radio interference
-
Operating Current Rating Per Function In Amps:
8.0 6th radio interference
-
Operating Current Rating Per Function In Amps:
2.0 4th radio interference
-
Operating Current Rating Per Function In Amps:
2.0 5th radio interference
-
Operating Current Rating Per Function In Amps:
2.5 1st radio interference
-
Operating Current Rating Per Function In Amps:
2.5 3rd radio interference
-
Operating Current Rating Per Function In Amps:
2.5 2nd radio interference
-
Maximum Voltage Drop Per Function:
500.0 millivolts ac 2nd radio interference
-
Maximum Voltage Drop Per Function:
500.0 millivolts ac 3rd radio interference
-
Maximum Voltage Drop Per Function:
500.0 millivolts ac 1st radio interference
-
Maximum Voltage Drop Per Function:
500.0 millivolts ac 4th radio interference
-
Maximum Voltage Drop Per Function:
500.0 millivolts ac 5th radio interference
-
Maximum Voltage Drop Per Function:
500.0 millivolts ac 6th radio interference
-
Output Terminal Manufacturer Code:
96906
-
Output Terminal Identification:
Ms3122e-18-11sw
-
Maximum Tempurature Rise:
25.0 degrees celsius
-
Mounting Facility Screw Thread Series Designator:
Unc
-
Inclosure Type:
Encased
-
Mounting Facility Type And Quantity:
4 threaded stud
-
Functional Terminal Type And Quantity:
1 connector, receptacle output 2nd function
-
Functional Terminal Type And Quantity:
2 tab, solder lug ground 3rd function
-
Functional Terminal Type And Quantity:
9 tab, solder lug input 1st function
-
Operating Voltage Rating And Type Per Function:
22.0 volts ac 6th radio interference 6th function
-
Operating Voltage Rating And Type Per Function:
26.0 volts ac 5th radio interference 5th function
-
Operating Voltage Rating And Type Per Function:
26.0 volts ac 4th radio interference 4th function
-
Operating Voltage Rating And Type Per Function:
115.0 volts ac 1st radio interference 1st function
-
Operating Voltage Rating And Type Per Function:
115.0 volts ac 2nd radio interference 2nd function
-
Operating Voltage Rating And Type Per Function:
115.0 volts ac 3rd radio interference 3rd function
-
Thread Size:
0.164 inches
-
Body Material:
Metal
-
Body Surface Treatment:
Tin
-
Style Designator:
Rectangular terminal/terminals on opposite surfaces
-
Federal Supply Class (fsc):
Filters and networks
-
National Stock Number (nsn):
5915-00-914-3232
-
Special Features:
8 functions