Features
16.500 inches nominal overall length.
12.400" overall width 117.0 ac voltage in volts and current type.
Includes quality control certificate of conformance.
Specifications
-
Overall Height:
5.000 inches
-
Overall Width:
12.400 inches
-
Maximum Measured Distance:
2000.0 feet
-
Power Source:
External and self-contained
-
Voltage In Volts And Current Type:
117.0 ac and 12.0 dc
-
Frequency In Hertz:
48.0 and 410.0
-
Functional Description:
Metallic cable testing; used to identify and locate cable faults
-
Federal Supply Class (fsc):
Electrical and electronic properties measuring and testing instruments
-
National Stock Number (nsn):
6625-01-037-4412
-
Special Features:
Single phase; single item w/housing; weighs 18 lbs; included accessories: watertight front cover (200-1759-00), tdr slide rule, (003-0700-00), 50 ohm bnc terminator (011-0123-00), precision 50 ohm cable (012-0482-00), viewing hood (016-0297-00), x-y output module (016-0606-00), 110v ac replacement fuses (for front panel) (159-0032-00), or 220v ac (159-0029-01), power cord (161-0066-00), mesh filter (crt) (378-0055-00), bnc female-to-female adaptor (103-0028-00), 9 ft bnc-to-clip-lead cable (012-0671-02), manual; opt 04 includes cable tester recorder; ac volts 234.0