Multimeter

Part Number 12206

Quality inspected with certificate of conformity. For questions and pricing call us at +1 210-468-8090

We ship worldwide

Features

7.000 inches nominal overall length, plastic phenol-formaldehyde material.

5.250" overall width electrical overload protection portable.

Includes quality control certificate of conformance.

Specifications

  • Circuit Current For Which Designed:
    Ac and dc
  • Overall Depth:
    3.125 inches
  • Overall Width:
    5.250 inches
  • Scale Division Quantity:
    25 single indicator 1st range
  • Scale Division Quantity:
    50 single indicator 10th range
  • Scale Division Quantity:
    50 single indicator 6th range
  • Scale Division Quantity:
    50 single indicator 7th range
  • Scale Division Quantity:
    50 single indicator 8th range
  • Scale Division Quantity:
    50 single indicator 9th range
  • Scale Division Quantity:
    50 single indicator 2nd range
  • Environmental Protection:
    Dust resistant and humidity resistant and vibration resistant
  • Furnished Items And Quantity:
    Btry 2; color-coded test leads 2; screw-on clips 2; instruction manual 1
  • Indicator Type:
    Dial w/pointer
  • Installation Design:
    Bench or hand held
  • Sensitivity Rating:
    5.0 kilohm per volt and 20.0 kilohm per volt
  • Dial Scale Marking Color:
    Black single indicator 10th range
  • Dial Scale Marking Color:
    Black single indicator 3rd range and red single indicator 3rd range
  • Dial Scale Marking Color:
    Black single indicator 4th range
  • Dial Scale Marking Color:
    Black single indicator 2nd range
  • Dial Scale Marking Color:
    Black single indicator 5th range
  • Dial Scale Marking Color:
    Black single indicator 6th range
  • Dial Scale Marking Color:
    Black single indicator 7th range
  • Dial Scale Marking Color:
    Black single indicator 8th range
  • Dial Scale Marking Color:
    Black single indicator 9th range
  • Dial Scale Marking Color:
    Green, light single indicator 1st range
  • Accuracy In Percent:
    -1.5/+1.5 at full scale single indicator 6th range
  • Accuracy In Percent:
    -2.0/+2.0 at full scale single indicator 10th range
  • Accuracy In Percent:
    -2.0/+2.0 at full scale single indicator 1st range
  • Accuracy In Percent:
    -2.0/+2.0 at full scale single indicator 2nd range
  • Accuracy In Percent:
    -2.0/+2.0 at full scale single indicator 3rd range
  • Accuracy In Percent:
    -2.0/+2.0 at full scale single indicator 5th range
  • Accuracy In Percent:
    -2.0/+2.0 at full scale single indicator 7th range
  • Accuracy In Percent:
    -2.0/+2.0 at full scale single indicator 8th range
  • Accuracy In Percent:
    -2.5/+2.5 at full scale single indicator 4th range
  • Accuracy In Percent:
    -3.0/+3.0 at full scale single indicator 9th range
  • Movement Type:
    Moving coil, permanent magnet
  • Background Color:
    White single indicator all ranges
  • Pointer Color:
    Red single indicator all ranges
  • Power Source:
    External and internal
  • Scale Graduation Type:
    Linear single indicator 10th range
  • Scale Graduation Type:
    Linear single indicator 1st range
  • Scale Graduation Type:
    Linear single indicator 2nd range
  • Scale Graduation Type:
    Linear single indicator 6th range
  • Scale Graduation Type:
    Linear single indicator 7th range
  • Scale Graduation Type:
    Linear single indicator 8th range
  • Scale Graduation Type:
    Linear single indicator 9th range
  • Scale Graduation Type:
    Nonlinear single indicator 3rd range
  • Scale Graduation Type:
    Nonlinear single indicator 4th range
  • Scale Graduation Type:
    Nonlinear single indicator 5th range
  • Measurement Range:
    +0.0/+10.0 megohms single indicator 5th range
  • Measurement Range:
    +0.0/+100.0 kilohms single indicator 4th range
  • Measurement Range:
    +0.0/+1000.0 volts, ac single indicator 9th range
  • Measurement Range:
    +0.0/+1000.0 volts, dc single indicator 10th range
  • Measurement Range:
    +0.0/+250.0 amperes, ac single indicator 1st range
  • Measurement Range:
    +0.0/+250.0 millivolts, dc single indicator 8th range
  • Measurement Range:
    -20.0/+10.0 decibels single indicator 3rd range
  • Measurement Range:
    +0.0/+5.0 amperes, dc single indicator 2nd range
  • Measurement Range:
    +0.0/+50.0 microamperes, dc single indicator 6th range
  • Measurement Range:
    +0.0/+500.0 milliamperes, dc single indicator 7th range
  • Scale Selection Method:
    Switch and terminal
  • Features Provided:
    Electrical overload protection and internal battery accommodation and internal shunting and mirror scale and portable and rectifier circuit and zero adjuster
  • Movement Suspension Method:
    Taut band
  • Circuit Attachment Method And Quantity:
    2 banana jack and 2 banana plug
  • Operating Voltage Rating In Volts:
    Between 1.5 dc and 9.0 dc
  • Special Markings:
    Black-sign, red + sign, below bottom scale
  • Style Designator:
    Portable
  • Fsc Application Data:
    Test set, elect. Equip.
  • Federal Supply Class (fsc):
    Electrical and electronic properties measuring and testing instruments
  • National Stock Number (nsn):
    6625-01-458-5859
  • Special Features:
    Lack-so-ver-load

Price Quote and Buy

Receive a quote by email then order online or over the phone.
6625014585859
Privacy    Terms

Quality Distribution Professional and certified distributor

  • ISO 9001:2015 + AS9120B
  • ITAR Registered
  • Quality inspected NSNs
  • Counterfeit Parts Prevention