7.000 inches nominal overall length.
5.250" overall width portable.
Includes quality control certificate of conformance.
-
Circuit Current For Which Designed:
Ac and dc
-
Overall Depth:
3.125 inches
-
Overall Width:
5.250 inches
-
Furnished Items And Quantity:
Leads 2
-
Indicator Type:
Dial w/pointer
-
Installation Design:
Bench
-
Sensitivity Rating:
50.0 microamperes
-
Dial Scale Marking Color:
Black single indicator all ranges
-
Accuracy In Percent:
-1.5/+1.5 at full scale single indicator 7th range
-
Accuracy In Percent:
-2.0/+2.0 at full scale single indicator 10th range
-
Accuracy In Percent:
-2.0/+2.0 at full scale single indicator 11th range
-
Accuracy In Percent:
-2.0/+2.0 at full scale single indicator 12th range
-
Accuracy In Percent:
-2.0/+2.0 at full scale single indicator 1st range
-
Accuracy In Percent:
-2.0/+2.0 at full scale single indicator 2nd range
-
Accuracy In Percent:
-2.0/+2.0 at full scale single indicator 3rd range
-
Accuracy In Percent:
-2.0/+2.0 at full scale single indicator 4th range
-
Accuracy In Percent:
-2.0/+2.0 at full scale single indicator 5th range
-
Accuracy In Percent:
-2.0/+2.0 at full scale single indicator 6th range
-
Accuracy In Percent:
-2.0/+2.0 at full scale single indicator 8th range
-
Accuracy In Percent:
-2.0/+2.0 at full scale single indicator 9th range
-
Accuracy In Percent:
-2.5/+2.5 at full scale single indicator 13th range
-
Background Color:
White single indicator all ranges
-
Pointer Color:
Red single indicator all ranges
-
Power Source:
Internal
-
Scale Graduation Type:
Linear single indicator 1st range
-
Scale Graduation Type:
Linear single indicator 2nd range
-
Scale Graduation Type:
Linear single indicator 3rd range
-
Scale Graduation Type:
Linear single indicator 4th range
-
Scale Graduation Type:
Linear single indicator 5th range
-
Scale Graduation Type:
Linear single indicator 6th range
-
Scale Graduation Type:
Linear single indicator 7th range
-
Scale Graduation Type:
Linear single indicator 8th range
-
Scale Graduation Type:
Nonlinear single indicator 10th range
-
Scale Graduation Type:
Nonlinear single indicator 11th range
-
Scale Graduation Type:
Nonlinear single indicator 12th range
-
Scale Graduation Type:
Nonlinear single indicator 13th range
-
Scale Graduation Type:
Nonlinear single indicator 9th range
-
Measurement Range:
+0.0/+1.0 volts single indicator 1st range
-
Measurement Range:
+0.0/+10.0 amperes, dc single indicator 8th range
-
Measurement Range:
+0.0/+10.0 kilohms single indicator 13th range
-
Measurement Range:
+0.0/+10.0 volts single indicator 3rd range
-
Measurement Range:
+0.0/+1000.0 volts single indicator 6th range
-
Measurement Range:
+0.0/+2.5 volts single indicator 2nd range
-
Measurement Range:
+6.0/+36.0 decibels above or below one milliwatt single indicator 11th range
-
Measurement Range:
-20.0/+10.0 decibels above or below one milliwatt single indicator 9th range
-
Measurement Range:
-8.0/+22.0 decibels above or below one milliwatt single indicator 10th range
-
Measurement Range:
+0.0/+50.0 microamperes, dc single indicator 7th range
-
Measurement Range:
+0.0/+50.0 volts single indicator 4th range
-
Measurement Range:
+0.0/+500.0 volts single indicator 5th range
-
Measurement Range:
+20.0/+50.0 decibels above or below one milliwatt single indicator 12th range
-
Scale Selection Method:
Switch and terminal
-
Movement Suspension Method:
Taut band
-
Circuit Attachment Method And Quantity:
Probe, direct contact
-
Style Designator:
Portable
-
Unit Of Issue Weight:
3.50 pounds
-
Federal Supply Class (fsc):
Electrical and electronic properties measuring and testing instruments
-
National Stock Number (nsn):
6625-00-998-6084