7.000 inches nominal overall length, plastic phenolic material.
5.250" overall width portable.
Includes quality control certificate of conformance.
-
Circuit Current For Which Designed:
Dc
-
Dielectric Withstanding Voltage In Volts:
1000.0
-
Overall Depth:
3.125 inches
-
Overall Width:
5.250 inches
-
Scale Division Quantity:
50 single indicator 1st range
-
Scale Division Quantity:
50 single indicator 3rd range
-
Scale Division Quantity:
50 single indicator 5th range
-
Scale Division Quantity:
50 single indicator 6th range
-
Scale Division Quantity:
50 single indicator 2nd range
-
Furnished Items And Quantity:
Leads, test 2; batteries 2; manual 1
-
Indicator Type:
Dial w/pointer
-
Installation Design:
Hand held
-
Frequency Response Range:
+0.020 to 50.000 kilohertz
-
Sensitivity Rating:
1000.0 ohms per volt
-
Dial Scale Marking Color:
Black single indicator 1st range
-
Dial Scale Marking Color:
Black single indicator 3rd range
-
Dial Scale Marking Color:
Black single indicator 4th range
-
Dial Scale Marking Color:
Black single indicator 5th range
-
Dial Scale Marking Color:
Black single indicator 6th range
-
Dial Scale Marking Color:
Red single indicator 2nd range
-
Accuracy In Percent:
-1.5 to 1.5 at full scale single indicator 6th range
-
Accuracy In Percent:
-2.0 to 2.0 at full scale single indicator 1st range
-
Accuracy In Percent:
-2.0 to 2.0 at full scale single indicator 3rd range
-
Accuracy In Percent:
-2.0 to 2.0 at full scale single indicator 4th range
-
Accuracy In Percent:
-2.0 to 2.0 at full scale single indicator 5th range
-
Accuracy In Percent:
-3.0 to 3.0 at full scale single indicator 2nd range
-
Movement Type:
Moving coil, permanent magnet
-
Background Color:
White single indicator all ranges
-
Pointer Color:
Red single indicator all ranges
-
Power Source:
Internal
-
Scale Graduation Type:
Linear single indicator 1st range
-
Scale Graduation Type:
Linear single indicator 2nd range
-
Scale Graduation Type:
Linear single indicator 3rd range
-
Scale Graduation Type:
Linear single indicator 5th range
-
Scale Graduation Type:
Linear single indicator 6th range
-
Scale Graduation Type:
Nonlinear single indicator 4th range
-
Measurement Range:
+0.0 to 20.0 megohms single indicator 4th range
-
Measurement Range:
+0.0 to 50.0 microamperes, dc single indicator 6th range
-
Measurement Range:
+0.0 to 500.0 milliamperes, dc single indicator 5th range
-
Measurement Range:
+0.0 to 10.0 amperes, dc single indicator 3rd range
-
Measurement Range:
+0.0 to 1000.0 volts, ac single indicator 2nd range
-
Measurement Range:
+0.0 to 1000.0 volts, dc single indicator 1st range
-
Scale Selection Method:
Switch
-
Movement Suspension Method:
Taut band
-
Circuit Attachment Method And Quantity:
2 wire lead
-
Nuclear Hardness Critical Feature:
Nonhardened
-
Style Designator:
Portable
-
Federal Supply Class (fsc):
Electrical and electronic properties measuring and testing instruments
-
National Stock Number (nsn):
6625-00-004-9536
-
Special Features:
Ohms accuracy is porm 1 deg. Of arc; measures from neg. 20 to pos. 50 decibles