Multimeter

Part Number ME-432/U

Quality inspected with certificate of conformity. For questions and pricing call us at +1 210-468-8090

We ship worldwide

Features

6.500 inches nominal overall length, plastic material.

5.125" overall width electrical overload protection portable.

Includes quality control certificate of conformance.

Specifications

  • Circuit Current For Which Designed:
    Ac and dc
  • Overall Depth:
    3.187 inches
  • Overall Width:
    5.125 inches
  • Scale Division Quantity:
    31 single indicator 3rd range
  • Scale Division Quantity:
    31 single indicator 6th range
  • Scale Division Quantity:
    31 single indicator 8th range
  • Scale Division Quantity:
    50 single indicator 5th range
  • Scale Division Quantity:
    50 single indicator 7th range
  • Scale Division Quantity:
    50 single indicator 2nd range
  • Indicator Type:
    Dial w/pointer
  • Installation Design:
    Bench
  • Sensitivity Rating:
    50.0 microamperes
  • Dial Scale Marking Color:
    Black single indicator all ranges
  • Accuracy In Percent:
    -2.0/+2.0 at full scale single indicator 4th range
  • Accuracy In Percent:
    -2.0/+2.0 at full scale single indicator 7th range
  • Accuracy In Percent:
    -2.0/+2.0 at full scale single indicator 8th range
  • Accuracy In Percent:
    -3.0/+3.0 at full scale single indicator 1st range
  • Accuracy In Percent:
    -3.0/+3.0 at full scale single indicator 3rd range
  • Accuracy In Percent:
    -3.0/+3.0 at full scale single indicator 5th range
  • Accuracy In Percent:
    -3.0/+3.0 at full scale single indicator 6th range
  • Accuracy In Percent:
    -4.0/+4.0 at full scale single indicator 2nd range
  • Accuracy In Percent:
    -2.0 to 2.0 at full scale single indicator 8th range
  • Accuracy In Percent:
    -2.0 to 2.0 at full scale single indicator 4th range
  • Accuracy In Percent:
    -2.0 to 2.0 at full scale single indicator 7th range
  • Accuracy In Percent:
    -3.0 to 3.0 at full scale single indicator 1st range
  • Accuracy In Percent:
    -3.0 to 3.0 at full scale single indicator 3rd range
  • Accuracy In Percent:
    -3.0 to 3.0 at full scale single indicator 5th range
  • Accuracy In Percent:
    -3.0 to 3.0 at full scale single indicator 6th range
  • Accuracy In Percent:
    -4.0 to 4.0 at full scale single indicator 2nd range
  • Background Color:
    White single indicator all ranges
  • Pointer Color:
    Black single indicator all ranges
  • Power Source:
    Internal
  • Scale Graduation Type:
    Linear single indicator 2nd range
  • Scale Graduation Type:
    Linear single indicator 3rd range
  • Scale Graduation Type:
    Linear single indicator 5th range
  • Scale Graduation Type:
    Linear single indicator 6th range
  • Scale Graduation Type:
    Linear single indicator 7th range
  • Scale Graduation Type:
    Linear single indicator 8th range
  • Scale Graduation Type:
    Nonlinear single indicator 1st range
  • Scale Graduation Type:
    Nonlinear single indicator 4th range
  • Measurement Range:
    +0.0/+1.0 milliamperes, ac single indicator 2nd range
  • Measurement Range:
    +0.0/+1.0 milliamperes, dc single indicator 3rd range
  • Measurement Range:
    +0.0/+1.0 volts, ac single indicator 5th range
  • Measurement Range:
    +0.0/+1.0 volts, dc single indicator 7th range
  • Measurement Range:
    +0.0/+1000.0 ohms single indicator 4th range
  • Measurement Range:
    +0.0/+3.0 volts, ac single indicator 6th range
  • Measurement Range:
    +0.0/+3.0 volts, dc single indicator 8th range
  • Measurement Range:
    -20.0/+2.0 decibels single indicator 1st range
  • Measurement Range:
    +0.0 to 1.0 milliamperes, ac single indicator 2nd range
  • Measurement Range:
    +0.0 to 1.0 milliamperes, dc single indicator 3rd range
  • Measurement Range:
    +0.0 to 1.0 volts, ac single indicator 5th range
  • Measurement Range:
    +0.0 to 1.0 volts, dc single indicator 7th range
  • Measurement Range:
    +0.0 to 1000.0 ohms single indicator 4th range
  • Measurement Range:
    +0.0 to 3.0 volts, ac single indicator 6th range
  • Measurement Range:
    +0.0 to 3.0 volts, dc single indicator 8th range
  • Measurement Range:
    -20.0 to 2.0 decibels single indicator 1st range
  • Scale Selection Method:
    Switch
  • Features Provided:
    Electrical overload protection and internal battery accommodation and portable and zero adjuster
  • Circuit Attachment Method And Quantity:
    2 probe, direct contact and 2 wire lead
  • Operating Voltage Rating In Volts:
    1.5 dc
  • Special Markings:
    Null guage: -; 0; +; band marked batt ok
  • Nuclear Hardness Critical Feature:
    Nonhardened
  • Style Designator:
    Portable
  • Fsc Application Data:
    Test set, elect. Equip.
  • Federal Supply Class (fsc):
    Electrical and electronic properties measuring and testing instruments
  • National Stock Number (nsn):
    6625-00-140-0029

Price Quote and Buy

Receive a quote by email then order online or over the phone.
6625001400029
Privacy    Terms

Quality Distribution Professional and certified distributor

  • ISO 9001:2015 + AS9120B
  • ITAR Registered
  • Quality inspected NSNs
  • Counterfeit Parts Prevention