Features
2.560 inches nominal overall length, steel material, enamel surface treatment.
Magnetic shield round flush mtg.
Includes quality control certificate of conformance.
Specifications
-
Circuit Current For Which Designed:
Dc
-
Dielectric Withstanding Voltage In Volts:
3000.0
-
Scale Division Quantity:
20 single indicator single range
-
Mounting Stud Length:
0.468 inches
-
Overall Diameter:
2.690 inches
-
Environmental Protection:
Shock resistant and vibration resistant
-
Mounting Bolt Circle Diameter:
2.440 inches
-
Furnished Items And Quantity:
Term. Hdw 2
-
Indicator Type:
Dial w/pointer
-
Installation Design:
Panel
-
Mounting Arrangement Style:
Three hole/stud bolt circle
-
Sensitivity Rating:
150.0 millivolts
-
Dial Scale Marking Color:
Black single indicator single range
-
Accuracy In Percent:
-2.0/+2.0 at full scale single indicator single range
-
Accuracy In Percent:
-2.0 to 2.0 at full scale single indicator single range
-
Unable To Decode:
Unable to decode or unable to decode
-
Meter Depth Behind Mounting Flange:
1.380 inches
-
Meter Body Diameter Behind Mounting Flange:
2.210 inches
-
Movement Type:
Moving iron vane
-
Background Color:
White single indicator single range
-
Pointer Color:
Black single indicator single range
-
Scale Marking:
Degrees; m 10; m 5; 0; 5; 10
-
Mounting Facility Type And Quantity:
3 threaded stud
-
Scale Graduation Type:
Linear single indicator single range
-
Mounting Stud Diameter:
0.112 inches
-
Features Provided:
Magnetic shield and zero adjuster
-
Circuit Attachment Method And Quantity:
2 solder lug and 2 threaded stud
-
Nuclear Hardness Critical Feature:
Nonhardened
-
Special Test Features:
Conforms to mil-m-10304/5, mr26w1h1dcuar
-
Style Designator:
Round flush mtg
-
Fsc Application Data:
Test set, elect, equip.
-
Federal Supply Class (fsc):
Electrical and electronic properties measuring and testing instruments
-
National Stock Number (nsn):
6625-00-478-3093
-
Special Features:
Ruggedized