Overall Height:
16.000 inches
-
Overall Width:
13.000 inches
-
Current Type:
Ac
-
Frequency Rating:
60.0 hertz
-
Accessory Components And Quantity:
2 adapter, post, 1 cord, power, 1 filter, light, 1 lead, test, 1 manual, instruction, 2 probes, 10 x attenuation
-
Voltage Rating:
125.0 volts
-
Beam Quantity:
1
-
Screen Size:
5 in.
-
Sweep Circuits:
Not included
-
Generator Driven Feature:
Not included
-
Expanded Sweep:
Not provided
-
Amplifier Deflection Sensitivity Provision:
Provided
-
Vertical Deflection Sensitivity Voltage Rating:
50.0 microvolts peak to peak per centimeter
-
Horizontal Deflection Sensitivity Voltage Rating:
200.0 millivolts any acceptable megahertz
-
Input Intensity Modulation Feature:
Not provided
-
Plate Direct Connection Deflection Sensitivity Provision:
Provided
-
Direct Connection Vertical Deflection Sensitivity Voltage Rating:
7.0 volts any acceptable megahertz
-
Direct Connection Horizontal Deflection Sensitivity Voltage Rating:
30.0 volts peak to peak per centimeter
-
Frequency Response Rating:
Provided
-
X-axis Frequency Response Rating:
Between 5.0 hertz and 240000.0 hertz
-
Y-axis Frequency Response Rating:
Between 5.0 hertz and 30000000.0 hertz
-
Amplifier Input Impedance Rating Provision:
Provided
-
X-axis Input Impedance Rating:
1.0 megohms
-
Y-axis Input Impedance Rating:
1.0 megohms
-
Z-axis Input Impedance Rating:
1.0 megohms
-
Calibrated Screen Scale:
Not included
-
Trace Storage Tube:
Not included
-
Camera Recording Device Accommodation:
Not provided
-
Phase:
Single
-
Functional Classification:
Aa-3.2
-
Functional Description:
High-speed laboratory oscilloscope w/fast rise time coupled with wide sweep-speed range and 10kilovolt accelerating voltage opens the way to faster, easier analysis of fast-rising waveforms. Additional adaptability is provided by plug-in preamplifiers which extends its use to almost all laboratory-oscilloscope applications. Accurately calibrated sweep speeds and vertical-deflection sensitivity permit quantitative time and amplitude measurements to be made. Accurately-delayed triggered sweeps make possible the selection and detailed observation of minute portions of voltage waves
-
Entry Date:
70-04-01
-
Reference Data And Literature:
Commercial handbook and to 33a1-13-73-1
-
Relationship To Similar Equipment:
INTE-RC-HAN-GEAB
-
Reference Number Differentiating Characteristics:
W/o amplifier
-
Federal Supply Class (fsc):
Electrical and electronic properties measuring and testing instruments
-
National Stock Number (nsn):
6625-00-553-7931
-
Special Features:
Ivertical plug-in units, for multiple-trace operation- type 1a1 dual-trace unit- dc to 33 mc, 10.5-nanosecond risetime at 50 mv/cm-dc to 23 mc, 15-nanosecond risetime at 5 mv/cm increasing to 33 mc at 50 mv/cm; type 1a2 dual-trace unit-dc to 33 mc, 10.5-nanosecond risetime at 50 mv/cm to 50 v/cm; type c-a dual-trace unit-dc to 24 mc, 15 nanosecond risetime at 50 mv/cm to 25 v/cm; type m four-trace unit-dc to 20 mc, 17-nanosecond risetime at 20 mv/cm to 25 v/cm