Noninductive Wire Wound Fixed Resistors - Page 1049 of 1441

36015 part numbers
RBR54L55300TP
View Part NSN 5905-01-076-9244 Cross Reference: MIL-PRF-39005/3, MIL-R-39005/3, RBR54L55300TM, RBR54L55300TR
  • Tempurature Coefficient Of Resistance In Ppm Per Deg Celsius: -10.0/+10.0
  • Electrical Resistance: 5.530 kilohms
  • Resistance Tolerance In Percent: -0.010/+0.010
  • Ambient Tempurature In Deg Celsius At Full Rated Power: 125.0
  • Ambient Tempurature In Deg Celsius At Zero Percent Rated Power: 145.0
RBR54L55300TR
View Part NSN 5905-01-076-9244 Cross Reference: MIL-PRF-39005/3, MIL-R-39005/3, RBR54L55300TM, RBR54L55300TP
  • Tempurature Coefficient Of Resistance In Ppm Per Deg Celsius: -10.0/+10.0
  • Electrical Resistance: 5.530 kilohms
  • Resistance Tolerance In Percent: -0.010/+0.010
  • Ambient Tempurature In Deg Celsius At Full Rated Power: 125.0
  • Ambient Tempurature In Deg Celsius At Zero Percent Rated Power: 145.0
RBR54L55500TR
View Part NSN 5905-00-242-2038 Cross Reference: MIL-PRF-39005/3, MIL-R-39005/3
  • Tempurature Coefficient Of Resistance In Ppm Per Deg Celsius: -10.0/+10.0
  • Electrical Resistance: 5.550 kilohms
  • Resistance Tolerance In Percent: -0.010/+0.010
  • Ambient Tempurature In Deg Celsius At Full Rated Power: 125.0
  • Ambient Tempurature In Deg Celsius At Zero Percent Rated Power: 145.0
RBR54L55560AR
View Part NSN 5905-01-015-8690 Cross Reference: MIL-PRF-39005/3, MIL-R-39005/3
  • Tempurature Coefficient Of Resistance In Ppm Per Deg Celsius: -10.0/+10.0
  • Electrical Resistance: 5.556 kilohms
  • Resistance Tolerance In Percent: -0.050/+0.050
  • Ambient Tempurature In Deg Celsius At Full Rated Power: 125.0
  • Ambient Tempurature In Deg Celsius At Zero Percent Rated Power: 145.0
RBR54L55600BR
View Part NSN 5905-01-230-2130 Cross Reference: MIL-PRF-39005/3, MIL-R-39005/3
  • Tempurature Coefficient Of Resistance In Ppm Per Deg Celsius: -10.0/+10.0
  • Electrical Resistance: 5.560 kilohms
  • Resistance Tolerance In Percent: -0.100/+0.100
  • Ambient Tempurature In Deg Celsius At Full Rated Power: 125.0
  • Ambient Tempurature In Deg Celsius At Zero Percent Rated Power: 145.0
RBR54L56000BR
View Part NSN 5905-00-262-0700 Cross Reference: MIL-PRF-39005/3, MIL-R-39005/3, RBR54S5601FM
  • Tempurature Coefficient Of Resistance In Ppm Per Deg Celsius: -10.0/+10.0
  • Electrical Resistance: 5.600 kilohms
  • Resistance Tolerance In Percent: -0.100/+0.100
  • Ambient Tempurature In Deg Celsius At Full Rated Power: 125.0
  • Ambient Tempurature In Deg Celsius At Zero Percent Rated Power: 145.0
RBR54L56001BR
View Part NSN 5905-00-314-3315 Cross Reference: MIL-R-39005/3
  • Tempurature Coefficient Of Resistance In Ppm Per Deg Celsius: -10.0/+10.0
  • Electrical Resistance: 56.000 kilohms
  • Resistance Tolerance In Percent: -0.100/+0.100
  • Ambient Tempurature In Deg Celsius At Full Rated Power: 125.0
  • Ambient Tempurature In Deg Celsius At Zero Percent Rated Power: 145.0
RBR54L56001QR
View Part NSN 5905-01-101-9917 Cross Reference: MIL-PRF-39005/3, MIL-R-39005/3
  • Tempurature Coefficient Of Resistance In Ppm Per Deg Celsius: -10.0/+10.0
  • Electrical Resistance: 56.000 kilohms
  • Resistance Tolerance In Percent: -0.020/+0.020
  • Ambient Tempurature In Deg Celsius At Full Rated Power: 125.0
  • Ambient Tempurature In Deg Celsius At Zero Percent Rated Power: 145.0
RBR54L56200FR
View Part NSN 5905-00-224-6173 Cross Reference: MIL-PRF-39005/3, MIL-R-39005/3
  • Tempurature Coefficient Of Resistance In Ppm Per Deg Celsius: -10.0/+10.0
  • Electrical Resistance: 5.620 kilohms
  • Resistance Tolerance In Percent: -1.000/+1.000
  • Ambient Tempurature In Deg Celsius At Full Rated Power: 125.0
  • Ambient Tempurature In Deg Celsius At Zero Percent Rated Power: 145.0
RBR54L56201BM
View Part NSN 5905-00-428-6009 Cross Reference: MIL-PRF-39005/3, MIL-R-39005/3, RBR54L56201BR
  • Tempurature Coefficient Of Resistance In Ppm Per Deg Celsius: -10.0/+10.0
  • Electrical Resistance: 56.200 kilohms
  • Resistance Tolerance In Percent: -0.100/+0.100
  • Ambient Tempurature In Deg Celsius At Full Rated Power: 125.0
  • Ambient Tempurature In Deg Celsius At Zero Percent Rated Power: 145.0
RBR54L56201BR
View Part NSN 5905-00-428-6009 Cross Reference: MIL-PRF-39005/3, MIL-R-39005/3, RBR54L56201BM
  • Tempurature Coefficient Of Resistance In Ppm Per Deg Celsius: -10.0/+10.0
  • Electrical Resistance: 56.200 kilohms
  • Resistance Tolerance In Percent: -0.100/+0.100
  • Ambient Tempurature In Deg Celsius At Full Rated Power: 125.0
  • Ambient Tempurature In Deg Celsius At Zero Percent Rated Power: 145.0
RBR54L56201FR
View Part NSN 5905-00-553-8444 Cross Reference: MIL-PRF-39005/3, MIL-R-39005/3
  • Tempurature Coefficient Of Resistance In Ppm Per Deg Celsius: -10.0/+10.0
  • Electrical Resistance: 56.200 kilohms
  • Resistance Tolerance In Percent: -1.000/+1.000
  • Ambient Tempurature In Deg Celsius At Full Rated Power: 125.0
  • Ambient Tempurature In Deg Celsius At Zero Percent Rated Power: 145.0
RBR54L56202AM
View Part NSN 5905-01-106-4393 Cross Reference: MIL-PRF-39005/3, MIL-R-39005/3, RBR54L56202AR
  • Tempurature Coefficient Of Resistance In Ppm Per Deg Celsius: -10.0/+10.0
  • Electrical Resistance: 562.000 kilohms
  • Resistance Tolerance In Percent: -0.050/+0.050
  • Ambient Tempurature In Deg Celsius At Full Rated Power: 125.0
  • Ambient Tempurature In Deg Celsius At Zero Percent Rated Power: 145.0
RBR54L56202AR
View Part NSN 5905-01-106-4393 Cross Reference: MIL-PRF-39005/3, MIL-R-39005/3, RBR54L56202AM
  • Tempurature Coefficient Of Resistance In Ppm Per Deg Celsius: -10.0/+10.0
  • Electrical Resistance: 562.000 kilohms
  • Resistance Tolerance In Percent: -0.050/+0.050
  • Ambient Tempurature In Deg Celsius At Full Rated Power: 125.0
  • Ambient Tempurature In Deg Celsius At Zero Percent Rated Power: 145.0
RBR54L562R0FR
View Part NSN 5905-00-189-1096 Cross Reference: 6893546-35, MIL-PRF-39005/3, MIL-R-39005/3, MILR93-12, RB54CE562R0F, WWA26-5550HM1-2W, WWA26X000B555R0F
  • Tempurature Coefficient Of Resistance In Ppm Per Deg Celsius: -10.0/+10.0
  • Electrical Resistance: 562.000 ohms
  • Resistance Tolerance In Percent: -1.000 to 1.000
  • Ambient Tempurature In Deg Celsius At Full Rated Power: 125.0
  • Ambient Tempurature In Deg Celsius At Zero Percent Rated Power: 145.0
RBR54L567R3BR
View Part NSN 5905-00-335-7644 Cross Reference: MIL-PRF-39005/3, MIL-R-39005/3
  • Tempurature Coefficient Of Resistance In Ppm Per Deg Celsius: -10.0/+10.0
  • Electrical Resistance: 567.300 ohms
  • Resistance Tolerance In Percent: -0.100/+0.100
  • Ambient Tempurature In Deg Celsius At Full Rated Power: 125.0
  • Ambient Tempurature In Deg Celsius At Zero Percent Rated Power: 145.0
RBR54L56900BR
View Part NSN 5905-01-030-2814 Cross Reference: MIL-PRF-39005/3, MIL-R-39005/3, RBR54S56900BR
  • Tempurature Coefficient Of Resistance In Ppm Per Deg Celsius: -10.0/+10.0
  • Electrical Resistance: 569.000 ohms
  • Resistance Tolerance In Percent: -0.100/+0.100
  • Ambient Tempurature In Deg Celsius At Full Rated Power: 125.0
  • Ambient Tempurature In Deg Celsius At Zero Percent Rated Power: 145.0
RBR54L56R00BR
View Part NSN 5905-00-332-9852 Cross Reference: MIL-PRF-39005/3, MIL-R-39005/3
  • Tempurature Coefficient Of Resistance In Ppm Per Deg Celsius: -15.0/+15.0
  • Electrical Resistance: 56.000 ohms
  • Resistance Tolerance In Percent: -0.100/+0.100
  • Ambient Tempurature In Deg Celsius At Full Rated Power: 125.0
  • Ambient Tempurature In Deg Celsius At Zero Percent Rated Power: 145.0
RBR54L56R20FR
View Part NSN 5905-00-200-9543 Cross Reference: MIL-PRF-39005/3, MIL-R-39005/3, RNC55J2432FM
  • Tempurature Coefficient Of Resistance In Ppm Per Deg Celsius: -15.0/+15.0
  • Electrical Resistance: 56.200 ohms
  • Resistance Tolerance In Percent: -1.000/+1.000
  • Ambient Tempurature In Deg Celsius At Full Rated Power: 125.0
  • Ambient Tempurature In Deg Celsius At Zero Percent Rated Power: 145.0
RBR54L57601BR
View Part NSN 5905-01-274-9030 Cross Reference: MIL-PRF-39005/3, MIL-R-39005/3
  • Tempurature Coefficient Of Resistance In Ppm Per Deg Celsius: -10.0/+10.0
  • Electrical Resistance: 57.600 kilohms
  • Resistance Tolerance In Percent: -0.100/+0.100
  • Ambient Tempurature In Deg Celsius At Full Rated Power: 125.0
  • Ambient Tempurature In Deg Celsius At Zero Percent Rated Power: 145.0
RBR54L57601FR
View Part NSN 5905-01-044-0549 Cross Reference: MILR39005
  • Tempurature Coefficient Of Resistance In Ppm Per Deg Celsius: -10.0/+10.0
  • Electrical Resistance: 57.600 kilohms
  • Resistance Tolerance In Percent: -1.000/+1.000
  • Ambient Tempurature In Deg Celsius At Full Rated Power: 125.0
  • Ambient Tempurature In Deg Celsius At Zero Percent Rated Power: 145.0
RBR54L576R0FR
View Part NSN 5905-00-284-8934 Cross Reference: 23002970-33, MIL-PRF-39005/3, MILR39005-3, WWA2600K578R0F
  • Tempurature Coefficient Of Resistance In Ppm Per Deg Celsius: -10.0/+10.0
  • Electrical Resistance: 576.000 ohms
  • Resistance Tolerance In Percent: -1.000/+1.000
  • Ambient Tempurature In Deg Celsius At Full Rated Power: 125.0
  • Ambient Tempurature In Deg Celsius At Zero Percent Rated Power: 145.0
RBR54L57R15BR
View Part NSN 5905-00-478-5462 Cross Reference: MIL-PRF-39005/3, MIL-R-39005/3
  • Tempurature Coefficient Of Resistance In Ppm Per Deg Celsius: -10.0/+10.0
  • Electrical Resistance: 57.150 ohms
  • Resistance Tolerance In Percent: -0.100/+0.100
  • Ambient Tempurature In Deg Celsius At Full Rated Power: 125.0
  • Ambient Tempurature In Deg Celsius At Zero Percent Rated Power: 145.0
RBR54L59700BR
View Part NSN 5905-00-224-6532 Cross Reference: MIL-PRF-39005/3, MIL-R-39005/3, MILR93-12, RB54CE59700D
  • Tempurature Coefficient Of Resistance In Ppm Per Deg Celsius: -10.0/+10.0
  • Electrical Resistance: 5.970 kilohms
  • Resistance Tolerance In Percent: -0.100/+0.100
  • Ambient Tempurature In Deg Celsius At Full Rated Power: 125.0
  • Ambient Tempurature In Deg Celsius At Zero Percent Rated Power: 145.0
RBR54L5R000BR
View Part NSN 5905-01-104-7972 Cross Reference: MIL-PRF-39005/3, MILR39005-3
  • Tempurature Coefficient Of Resistance In Ppm Per Deg Celsius: -30.0/+30.0
  • Electrical Resistance: 5.000 ohms
  • Resistance Tolerance In Percent: -0.100/+0.100
  • Ambient Tempurature In Deg Celsius At Full Rated Power: 125.0
  • Ambient Tempurature In Deg Celsius At Zero Percent Rated Power: 145.0