Reliability Indicator:
Not established
-
Terminal Surface Treatment:
Solder
-
Terminal Length:
3.750 inches
-
Center To Center Distance Between Mounting Facilities Parallel To Length:
1.0624 inches
-
Center To Center Distance Between Mounting Facilities Parallel To Width:
0.6874 inches
-
Overall Height:
0.313 inches
-
Overall Width:
0.875 inches
-
Terminal Diameter:
0.025 inches
-
Unthreaded Mounting Hole Diameter:
0.1285 inches
-
Ambient Tempurature At Full Rated Power:
25.0 degrees celsius
-
Maximum Operating Temp:
150.0 degrees celsius
-
Thermal Time Constant In Seconds:
80.0
-
Power Dissipation Constant In Milliwatts Per Deg Celsius:
150.0
-
Zero Power Tempurature Coefficient Of Resistance In Percent Per Deg Celsius:
4.40
-
Tempurature Points For Resistance Readings At Zero Power:
-10.0 degrees celsius 3rd resistance-temperature point
-
Tempurature Points For Resistance Readings At Zero Power:
-30.0 degrees celsius 2nd resistance-temperature point
-
Tempurature Points For Resistance Readings At Zero Power:
-50.0 degrees celsius 1st resistance-temperature point
-
Tempurature Points For Resistance Readings At Zero Power:
0.0 degrees celsius 4th resistance-temperature point
-
Tempurature Points For Resistance Readings At Zero Power:
100.0 degrees celsius 8th resistance-temperature point
-
Tempurature Points For Resistance Readings At Zero Power:
125.0 degrees celsius 9th resistance-temperature point
-
Tempurature Points For Resistance Readings At Zero Power:
150.0 degrees celsius 10th resistance-temperature point
-
Tempurature Points For Resistance Readings At Zero Power:
25.0 degrees celsius 5th resistance-temperature point
-
Tempurature Points For Resistance Readings At Zero Power:
50.0 degrees celsius 6th resistance-temperature point
-
Tempurature Points For Resistance Readings At Zero Power:
75.0 degrees celsius 7th resistance-temperature point
-
Zero Power Resistance At Specificationified Temp:
25.375 ohms 9th resistance-temperature point
-
Zero Power Resistance At Specificationified Temp:
3.045 kilohms 3rd resistance-temperature point
-
Zero Power Resistance At Specificationified Temp:
46.4 kilohms 1st resistance-temperature point
-
Zero Power Resistance At Specificationified Temp:
58.0 ohms 8th resistance-temperature point
-
Zero Power Resistance At Specificationified Temp:
725.0 ohms 5th resistance-temperature point
-
Zero Power Resistance At Specificationified Temp:
116.0 ohms 7th resistance-temperature point
-
Zero Power Resistance At Specificationified Temp:
13.05 ohms 10th resistance-temperature point
-
Zero Power Resistance At Specificationified Temp:
13.05 kilohms 2nd resistance-temperature point
-
Zero Power Resistance At Specificationified Temp:
2.465 kilohms 4th resistance-temperature point
-
Zero Power Resistance At Specificationified Temp:
239.25 ohms 6th resistance-temperature point
-
Resistance Tolerance At A Specificationified Tempurature In Percent:
-10.0/+10.0 9th resistance-temperature point
-
Resistance Tolerance At A Specificationified Tempurature In Percent:
-11.0/+11.0 1st resistance-temperature point
-
Resistance Tolerance At A Specificationified Tempurature In Percent:
-12.1/+12.1 10th resistance-temperature point
-
Resistance Tolerance At A Specificationified Tempurature In Percent:
-5.0/+5.0 5th resistance-temperature point
-
Resistance Tolerance At A Specificationified Tempurature In Percent:
-7.0/+7.0 4th resistance-temperature point
-
Resistance Tolerance At A Specificationified Tempurature In Percent:
-7.0/+7.0 6th resistance-temperature point
-
Resistance Tolerance At A Specificationified Tempurature In Percent:
-8.6/+8.6 7th resistance-temperature point
-
Resistance Tolerance At A Specificationified Tempurature In Percent:
-8.4/+8.4 3rd resistance-temperature point
-
Resistance Tolerance At A Specificationified Tempurature In Percent:
-9.0/+9.0 2nd resistance-temperature point
-
Resistance Tolerance At A Specificationified Tempurature In Percent:
-8.9/+8.9 8th resistance-temperature point
-
Resistance Tolerance At A Specificationified Tempurature In Percent:
-7.0 to 7.0 4th resistance-temperature point
-
Resistance Tolerance At A Specificationified Tempurature In Percent:
-7.0 to 7.0 6th resistance-temperature point
-
Resistance Tolerance At A Specificationified Tempurature In Percent:
-8.9 to 8.9 8th resistance-temperature point
-
Resistance Tolerance At A Specificationified Tempurature In Percent:
-11.0 to 11.0 1st resistance-temperature point
-
Distance Between Mounting Facility Centers:
1.000 inches
-
Inclosure Type:
Encapsulated
-
Cubic Measure:
0.342 cubic inches
-
Zero Power Resistance:
725.000 ohms
-
Zero Power Resistance Tolerance In Percent At Reference Temp:
-5.0/+5.0
-
Reference Tempurature In Deg Celsius:
25.0
-
Style Designator:
Disk on surface plate
-
Terminal Type And Quantity:
1 wire lead
-
Federal Supply Class (fsc):
Resistors
-
National Stock Number (nsn):
5905-00-175-5447