0.125 inches minimum and 0.155 inches maximum body outside diameter.

Rod.

Includes quality control certificate of conformance.

Specifications

  • Reliability Indicator:
    Not established
  • Terminal Surface Treatment:
    Solder
  • Terminal Length:
    1.000 inches
  • Body Length:
    Between 0.390 inches and 0.420 inches
  • Terminal Diameter:
    0.025 inches
  • Maximum Power Dissipation Rating:
    125.00 milliwatts
  • Ambient Tempurature At Full Rated Power:
    100.0 degrees celsius
  • Maximum Operating Temp:
    125.0 degrees celsius
  • Thermal Time Constant In Seconds:
    35.0
  • Power Dissipation Constant In Milliwatts Per Deg Celsius:
    2.5
  • Zero Power Tempurature Coefficient Of Resistance In Percent Per Deg Celsius:
    0.70
  • Tempurature Points For Resistance Readings At Zero Power:
    -25.0 degrees celsius 4th resistance-temperature point
  • Tempurature Points For Resistance Readings At Zero Power:
    -50.0 degrees celsius 3rd resistance-temperature point
  • Tempurature Points For Resistance Readings At Zero Power:
    -75.0 degrees celsius 1st resistance-temperature point
  • Tempurature Points For Resistance Readings At Zero Power:
    -65.0 degrees celsius 2nd resistance-temperature point
  • Tempurature Points For Resistance Readings At Zero Power:
    0.0 degrees celsius 5th resistance-temperature point
  • Tempurature Points For Resistance Readings At Zero Power:
    100.0 degrees celsius 8th resistance-temperature point
  • Tempurature Points For Resistance Readings At Zero Power:
    125.0 degrees celsius 9th resistance-temperature point
  • Tempurature Points For Resistance Readings At Zero Power:
    150.0 degrees celsius 10th resistance-temperature point
  • Tempurature Points For Resistance Readings At Zero Power:
    50.0 degrees celsius 6th resistance-temperature point
  • Tempurature Points For Resistance Readings At Zero Power:
    75.0 degrees celsius 7th resistance-temperature point
  • Zero Power Resistance At Specificationified Temp:
    3.4 kilohms 4th resistance-temperature point
  • Zero Power Resistance At Specificationified Temp:
    4.2 kilohms 5th resistance-temperature point
  • Zero Power Resistance At Specificationified Temp:
    6.1 kilohms 6th resistance-temperature point
  • Zero Power Resistance At Specificationified Temp:
    7.2 kilohms 7th resistance-temperature point
  • Zero Power Resistance At Specificationified Temp:
    8.5 kilohms 8th resistance-temperature point
  • Zero Power Resistance At Specificationified Temp:
    10.2 kilohms 9th resistance-temperature point
  • Zero Power Resistance At Specificationified Temp:
    11.4 kilohms 10th resistance-temperature point
  • Zero Power Resistance At Specificationified Temp:
    2.2 kilohms 1st resistance-temperature point
  • Zero Power Resistance At Specificationified Temp:
    2.4 kilohms 2nd resistance-temperature point
  • Zero Power Resistance At Specificationified Temp:
    2.7 kilohms 3rd resistance-temperature point
  • Resistance Tolerance At A Specificationified Tempurature In Percent:
    -10.1 to 10.1 10th resistance-temperature point
  • Resistance Tolerance At A Specificationified Tempurature In Percent:
    -5.3 to 5.3 5th resistance-temperature point
  • Resistance Tolerance At A Specificationified Tempurature In Percent:
    -6.6/+6.6 6th resistance-temperature point
  • Resistance Tolerance At A Specificationified Tempurature In Percent:
    -7.2/+7.2 7th resistance-temperature point
  • Resistance Tolerance At A Specificationified Tempurature In Percent:
    -6.7/+6.7 4th resistance-temperature point
  • Resistance Tolerance At A Specificationified Tempurature In Percent:
    -8.0/+8.0 2nd resistance-temperature point
  • Resistance Tolerance At A Specificationified Tempurature In Percent:
    -7.4 to 7.4 3rd resistance-temperature point
  • Resistance Tolerance At A Specificationified Tempurature In Percent:
    -8.5 to 8.5 8th resistance-temperature point
  • Resistance Tolerance At A Specificationified Tempurature In Percent:
    -8.3 to 8.3 1st resistance-temperature point
  • Resistance Tolerance At A Specificationified Tempurature In Percent:
    -9.2/+9.2 9th resistance-temperature point
  • Inclosure Type:
    Encapsulated
  • Zero Power Resistance:
    5.100 kilohms
  • Zero Power Resistance Tolerance In Percent At Reference Temp:
    -5.0/+5.0
  • Reference Tempurature In Deg Celsius:
    25.0
  • Style Designator:
    Rod
  • Test Data Document:
    81349-mil-t-23648 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.).
  • Terminal Type And Quantity:
    2 wire lead
  • Federal Supply Class (fsc):
    Resistors
  • National Stock Number (nsn):
    5905-00-038-5729